Power Factor
measures true power over apparent power.
-
Product
Power Factor Controllers
-
ENTES Reactive Power Factor Controllers try to match the system''s power factor which is defined as the ratio of the active power to the apparent power to the user defined power factor value by controlling the facility''s reactive power using capacitor banks.
-
Product
Power Factor Regulators
-
National Meter Industries Inc.
has been designed toenable easy, effective regulation.
-
Product
Power Factor Transducer
*(0.2%ACC.) : TDPF. *(0.5%ACC.) : TSPF
-
Kusam Electrical Industries Limited
• Dual Aux. Power 110/220V AC• High Accuracy 0.2% RO at 23 °C± 5 °C• High Dielectric Strength 2.6KV AC / Min, Between Input / Output/ Power Case• ABS Plastic Case, DIN Rail or Wall Mounting
-
Product
Capacitance & Tan Δ Power Factor Meter 2.5kV
CAPO 2.5
-
The measuring instrument CAPO 2.5 is a new Capacitance and tan δ / Power Factor Test Set developed by Raytech Engineers.
-
Product
Power Factor RLC Load
3282(280V,1875W / 3700VA )
-
3282 power Factor RLC Load built-in 16-bit A/D and DSP precision measurement circuit, provides accurate measurements, measurement items have Vrms, Arms, Watt, VA, CF, PF, THD, VTHD, ITHD, Ipeak, Amax, Amin, Vmax, and Vmin. In addition to these measurement functions, it also provides time measurement,products such as UPS, fuses and circuit breakers etc. trip or blow time and transfer time for Off-line UPS
-
Product
Amp, Power Factor & VAR Recorder
Varcorder
-
The Varcorder measures and records Amps and Power Factor. A voltage constant is then applied in software to calculate VARs. The Varcorder uses the same current sensor technology as the original Ampstik. This patented amp sensor does not use magnetic materials and has no moving parts. The opening of the sensor is electronically closed, and external currents are electronically rejected. The accuracy, external current reject, and range of currents measured by the patented amp sensor substantially exceed the performance of the best clamp-on sensors. The true power factor is calculated by measuring the electric field in comparison with the current reported from the amp sensor. The key feature of the unit is the ability to leave it deployed on the line to record readings every 15 minutes for 90+ days. It easily attaches to the line with a standard shotgun style hotstick. Once on the line, it immediately begins to collect and record the current and power factor on the line.
-
Product
Capacitance & Tan Δ Power Factor Meter 12kV
CAPO-12
-
The CAPO 12 is a fully automatic Capacitance, Insulation Power Factor / tan δ measuring instrument developed by Raytech Engineers. The self-contained instrument performs measurements of Insulation Power Factor (cos ᵠ), Dissipation Factor (tan δ), Capacitance, Inductance, Excitation, Quality Factor and Power Loss (watts). Measurements can be made up to 12kVAC at variable frequency (from 10Hz to 400Hz).
-
Product
Power Factor Controller
-
Rishabh Instruments Pvt. Ltd.,
Is an intelligent power factor controller for reactive power compensation. It has 4 / 6 / 8 control outputs with LED Display for target PF.
-
Product
Power Factor Correction
HV/MV
-
Power Capacitors for medium voltage network:Ducati Energia proposal includes range of single and three-phase capacitors up to 800 kVAr with max HSV of 36kV.Upon request,we provide them with internal fuses stainless steel cases,inrush reactors,expulsion fuses as well.System is designed according to the specific application and it is composed by current transformers (CT),voltage transformers (VT) and relais.
-
Product
True RMS 1000V Wireless Multimeter w/ Power Factor
DM525
-
UEi Test & Measurement Instruments
The DM525 is a Industrial level multimeter with Wireless capability and a free App. It also has Watt/Power Factor lessening the chance of incorrect readings from ghost voltages. The increased functionality gives technicians the ability to do more.
-
Product
Portable Wattneter (Low Power Factor 0.2)
-
Supreme Instrument Laboratories
Range : 0-0.5/1 Amps, 0-50/100/200 Volts.0-0.5/1 Amps, 0-75/150/300 Volts0-0.5/1 Amps, 0-150/300/600 Volts0-0.5/1 Amps, 0-125/250/500 Volts
-
Product
LED Lighting Test Instrument Integrating Sphere
CX-I.5S
-
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
Product
Tri-phase High Power Programmable AC Power Source
APS50000
-
Advanced direct digital frequency sythesizer(DDS) waveform generation technology, high frequency stability, good continutyMeasurement precision is high, suitable for current half-sinusoid and its similar waveforms with DC component measurementProvide embedded intelligent PC monitoring systemAdjustable output voltage from 0 to 150V, 0 to 300V, step distance 0.1VOutput frequency 45-120Hz(40-500Hz optional), step distance 0.1 HzOutput current limiting functionWith 9 sets of memory, you can store commonly used parameters for easy invocation when using themWith RS232C communication interface 【IEEE488.0(GPIB)optional】, instruction execution times is less than 10mSProtechtion mode: over voltage, over current, overload, short circuit,current limit, ectProvide RMS voltage, RMS current, active power, frequency, power factor, ectFor 100% load removal, voltage stabilizing reaction time within 20ms, strong overload capacity, instantaneouscurrent can with stand 3 times of rated current
-
Product
Automatic Battery
BATLV800
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage instalations.
-
Product
Phase Sequence Indicator
-
Cambridge Instruments & Engineering Co.
Phase sequence indicator is a must for checking new electrical connections, installation and maintenance. It is useful in wiring of switchboards, when 3 phase watt meters and power factor meters are connected. In wiring 3 phase AC motors rotation can be checked and corrected if need be, by checking the sequence.
-
Product
Pump Testing Panel
VPTP
-
It covers No Load Test, Block Rotor Test, Pump Performance Test, Reduced Voltage Test for Submersible Pump, Monoblock Pump & Centrifugal Pump etc. Direct measurement of Voltage, Current Active Power, Power Factor (PF), Apparent Power, Frequency, Head, Suction, Discharge, RPM, Corrected RPM, %Slip.
-
Product
Automatic Power Factor Controller
-
Nippen Electrical Instruments Co.
NIPPEN Model UNO+ is used for measurement and control of PF using Reactive power compensation. Capacitor banks are suitably switched ON and OFF automatically to provide necessary compensation.An Intelligent switching algorithm (Wear leveling) ensures uniform aging of the capacitors used to achieve the Target PF. An Alarm function ensures protection of capacitor banks against abnormality in voltage, current and sets value of capacitors whenever these are beyond the higher and lower threshold limits.CT polarity is automatically sensed internally in the event of reverse connection.
-
Product
1-phase Power Analyzers
-
PeakTech Prüf- und Messtechnik GmbH
Is a high-precision energy cost measuring device for recording the energy consumption of electrical devices and for calculating the current consumption of a device by entering the electricity price. Thanks to the integrated power factor calculation, all modern consumers such as Switching power supplies, TV sets, fluorescent lamps, LED systems and of course ohmic loads such as Electric heaters and hobs can be measured accurately. In addition, the high resolution, the low response characteristic and even very small or stand-by consumers from approx. 1 W can be measured.
-
Product
TRMS AC/DC Clamp-on Power
HT9023
-
HT9023 has been designed to measure AC, DC AC+DC current up to 1000A in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010-1. The clamp also measures DC voltage up to 1500V, AC, AC+DC voltage up to 1000V, Active, Reactive and Apparent Power, Power Factor, Energy, voltage/current harmonic analysis up to the 25th with THD% calculation in balanced single-phase or three-phase systems.
-
Product
Rack-Mount Power Supplies
-
Explore rack-mount high voltage power supplies that feature IGBT switch mode technology or active power factor correction. And check out our rack-mount modules equipped with disc sets, which are ideal for ion-beam and electron-beam systems and X-ray equipment. Choose from standard modules or customize.
-
Product
Plug-In Power Supplies
-
VECTOR Electronics and Technology, Inc.
Standard PCI output Voltages : 5.0V, 3.3V, +12.0V, -12.0VHot swap, N+1 redundancy with internal OR-ing diodes.99 power factor corrected AC 90-264V input DC 36-72V (48V nom.), or DC 18-32V (24V nom.) Current sharing on 5.0V and 3.3V outputs Power & Fault LED indicators to faceplate Excellent performance
-
Product
Automatic Battery
BATLV1600
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage instalations. These equipments are supplied completely assembled and ready for use: it is only necessary to connect it to the mains with cablesof adequate cross section, and to supply the operation signal from suitable current transformer. FML capacitors and swichgear inside metal cabinet. Floor mounting.
-
Product
Intelligent Power Factor Regulator
Model -KM PFR 9-6 / 9-12
-
Kusam Electrical Industries Limited
The pioneers & leaders in high quality power factor controllers & maximum demand controllers, now introduce 2 new economy models of power factor controllers. These controllers have microprocessors for automatic control of power factor. It has digital indication for power factor.
-
Product
Automatic Batteries with Filters with Thyristors
BATLVFS1000
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage instalations.
-
Product
6U CompactPCI Intel® Atom® X6413E Processor Blade
cPCI-6660
-
The cPCI-6660 Series is a 6U CompactPCI single-board computer available in single-slot (4HP) or dual-slot (8HP) width form factors, powered by the Quad-core Intel Atom® x6413E Processor. The cPCI-6660 now supports dual-channel DDR4-2400-3200MT/s memory with In-Band ECC (IBECC) for enhanced reliability. It features a 5V power input, four 2.5GbE Ethernet ports (3x RJ-45 and 1x M12 X-coded), onboard iSLC, and offers flexible storage options, including an optional 2.5" SATA drive space or mSATA, configurable by BOM.
-
Product
Automatic Battery
BATLV480
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage instalations.
-
Product
Portable Power Factor Meter
ST-2000 Cos∮
-
Standard Electric Works Co., Ltd
● Principle : Phase angle sensing transducer● Rated Accuracy : ±3% phase angle● Scale : Power Factor:Lead 0 – 0.3 – 1.0 – 0.3 – 0 Lag Power Angle: Lead 90° – 0° – 90° Lag● Effective Power Factor Measuring Range : Lead 0.5 – 1.0 – 0.5 Lag● Scale Length : Approx. 135mm(5-3/8”)● Frequency Influence : Within ±1.5° phase angle at 45 to 65Hz
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF1200
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralizedcompensation of power factor in low voltage instalations