Power Factor
measures true power over apparent power.
-
Product
Power Factor Regulators
-
National Meter Industries Inc.
has been designed toenable easy, effective regulation.
-
Product
Power Factor Transducer
*(0.2%ACC.) : TDPF. *(0.5%ACC.) : TSPF
-
Kusam Electrical Industries Limited
• Dual Aux. Power 110/220V AC• High Accuracy 0.2% RO at 23 °C± 5 °C• High Dielectric Strength 2.6KV AC / Min, Between Input / Output/ Power Case• ABS Plastic Case, DIN Rail or Wall Mounting
-
Product
Power Factor Controllers
-
ENTES Reactive Power Factor Controllers try to match the system''s power factor which is defined as the ratio of the active power to the apparent power to the user defined power factor value by controlling the facility''s reactive power using capacitor banks.
-
Product
Capacitance & Tan Δ Power Factor Meter 12kV
CAPO-12
-
The CAPO 12 is a fully automatic Capacitance, Insulation Power Factor / tan δ measuring instrument developed by Raytech Engineers. The self-contained instrument performs measurements of Insulation Power Factor (cos ᵠ), Dissipation Factor (tan δ), Capacitance, Inductance, Excitation, Quality Factor and Power Loss (watts). Measurements can be made up to 12kVAC at variable frequency (from 10Hz to 400Hz).
-
Product
Portable Wattmeter (Unity Power Factor)
-
Supreme Instrument Laboratories
The Principle of working is Electo-dynamometer type for Wattmeters. Portable dynamometer type single phase Single element Wattmeter housed in laminated wooden cabinet size 235 mm length x 200 mm width x 180 mm height, with detachable lid, black bakelite panel fitted with anti-parallax mirror scale, knife edge pointer, rubber footings, carrying handles, locking arrangements.
-
Product
Amp, Power Factor & VAR Recorder
Varcorder
-
The Varcorder measures and records Amps and Power Factor. A voltage constant is then applied in software to calculate VARs. The Varcorder uses the same current sensor technology as the original Ampstik. This patented amp sensor does not use magnetic materials and has no moving parts. The opening of the sensor is electronically closed, and external currents are electronically rejected. The accuracy, external current reject, and range of currents measured by the patented amp sensor substantially exceed the performance of the best clamp-on sensors. The true power factor is calculated by measuring the electric field in comparison with the current reported from the amp sensor. The key feature of the unit is the ability to leave it deployed on the line to record readings every 15 minutes for 90+ days. It easily attaches to the line with a standard shotgun style hotstick. Once on the line, it immediately begins to collect and record the current and power factor on the line.
-
Product
Intelligent Power Factor Regulator
Model -KM PFR 9-6 / 9-12
-
Kusam Electrical Industries Limited
The pioneers & leaders in high quality power factor controllers & maximum demand controllers, now introduce 2 new economy models of power factor controllers. These controllers have microprocessors for automatic control of power factor. It has digital indication for power factor.
-
Product
Phase Angle and Power Factor Transducer of Single-phase AC Electric Power
NMTFi
-
The NMTFi device is a phase angle and power factor transducer operated in single-phase power network and featuring two independent analogous outputs. The A output measures the phase angle between voltage and current, the B output measures the power factor. In such a was one single NMFTi transducer is able to replace two customary transducers thus making it possible to achieve significant savings in installation space.
-
Product
Digital PFC Controllers with Power Metering
-
Are digital power factor correction (PFC) controllers that provide accurate input power metering capability and inrush current control for ac/dc systems.
-
Product
Automatic Batteries with Filters with Thyristors
BATLVFS1200
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage instalations
-
Product
Injection Transformer
J2101A
-
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
Product
Electronic Ballast Tester
WT4000
-
• Measure parameter: 1) Input: Vrms, Lrms, W, PF, Hz, Phasic angle, total harmonic and 0-39 component of harmonic. 2) Output: Lamp voltage, Lamp current, Filament current, Guided cathodic current, Lamp power, crest factor and oscillatory frequency, single high frequency analysis. • Startup: Startup lamp voltage, lamp current, filament current, guided cathodic current curve and parameter, preheating time; • Simultaneously display on 8 windows for input and output parameters, convenient for comparison and analysis; • Test preheat energy, filament preheat time. And the parameters changes from 0 to 5s of filament voltage, filament current and filament power; • Up to 1MHz lrms test content to every EB; • Analysis symmetry of high Frequency curve of lout; • 12-bit high-speed A/D, sampling rate up to 10MHz, can easily analyse signal curve of output; • Finish an input and output testing at the same time within 1 minute; • Portable, can test, display, print without computer. Test report include data and curve, comply with international standard; • Communication port for PC, run under Windows98 or Windows2000, English Version available.
-
Product
Automatic Power Factor Controller
-
Nippen Electrical Instruments Co.
NIPPEN Model UNO+ is used for measurement and control of PF using Reactive power compensation. Capacitor banks are suitably switched ON and OFF automatically to provide necessary compensation.An Intelligent switching algorithm (Wear leveling) ensures uniform aging of the capacitors used to achieve the Target PF. An Alarm function ensures protection of capacitor banks against abnormality in voltage, current and sets value of capacitors whenever these are beyond the higher and lower threshold limits.CT polarity is automatically sensed internally in the event of reverse connection.
-
Product
1000W to 1500W - Single Output / Multiple Output
ALPHA 1000/1500 Series (CA)
-
*1 to 16 regulated and independent outputs*Power Factor Corrected*No Minimum Load*Fast-on Tab Connections*Wide Range Input*Low Leakage Medical Options
-
Product
Power Supplies
NEO ECO SERIES
-
Get economical power today with the NeoECO C Series, Antec's high-efficiency power supply solution. Featuring 80 PLUS® BRONZE certification, a quiet double ball bearing 120mm fan, and universal input with active power factor correction (PFC), the NeoECO C series gives you a cooler, quieter system all powered by Continuous Power. The NeoECO C series also features industrial safety protection, including short circuit and over voltage protection, for stable and reliable power no matter what.
-
Product
HID Ballast Tester
WT2000-HID
-
• Input Parameters Measurement: 1) Test voltage, current, power, power factor, power line frequency, total harmonic and 0~50 harmonic 2) Range of voltage and current basic wave frequency: 45Hz~65Hz 3) Range of narrow frequency: 45Hz~5kHz 4) Range of wide frequency: 45Hz~1MHz
-
Product
GO-2000 Goniophotometer
-
Hangzhou Everfine Photo-E-Info Co., LTD
GO-2000 is a highly automated luminaire light distribution performance test system, mainly used for all kinds of indoor lamps, road lamps and floodlights ( add B-β test accessories) light distribution performance test, total luminous flux test and electrical parameters (voltage, current, power, power factor) measurement.
-
Product
PICMG® 2.11 47-pin Hot-Swap Redundant 3U CompactPCI® 8HP 250 W Power Module
cPS-H325/110
Power Module
- PICMG® 2.11 CompactPCI® Power Interface compliant- Internal OR-ing Diodes for N + 1 redundancy- PICMG® 2.11 47-pin CompactPCI® in-rack power module interface- 250 W DC output- Active PFC (Power Factor Correction) meets IEC1000-3-2 Harmonic Correction
-
Product
Three Phase Meter Test Bench
-
Supreme Instrument Laboratories
Three phase meter test bench suitable for calibration & testing of AC Ammeters, Voltmeters, Single phase Energy Meters, Watt Meters, Power Factor Meters, Three Phase Two Wire & Three Phase Four Wire Energy Meters Trivector Meters, Maximum demand indicators, of active & reactive systems, Three phase 3 wire & 4 wire watt meters, Var Meters, Power Factor Meters etc.
-
Product
Adjustable AC Power Meter
APS-6000
-
The APS-6000 adjustable AC power source is a multi-function AC power source that integrates voltage, current, power and power factors. The internal high-speed processor is a cost-effective, high-stability AC power source.
-
Product
Reactor Loss Measurement Systems
-
Measurements International Ltd.
The AccuLoss® SR2020 System by Measurements International emerges as a premium, dependable solution tailored for measuring losses in high-voltage shunt reactors. Specifically engineered to function seamlessly at remarkably low power factors, this system excels in applications demanding extensive scalability. Notably, the AccuLoss® SR2020 System offers two key advantages: unparalleled accuracy and remarkable speed.
-
Product
Customaizable Uninterrupted Power System
CT Series
-
The rugged CT Series is designed for applications in extreme temperature environments, such as offshore drilling rigs, refineries and shipboard use. An added benefit is that the CT Series can double as an electronic power conditioner/frequency converter as well. All CT systems utilize Power Factor Correction, and RS232 and SNMP protocols are supported.
-
Product
Power Quality Analyzer
-
Power quality analyzer is a product carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, man-machine operation and concise and comprehensive test instrument. It is easy to use, large LCD screen display, high resolution, interface in both Chinese and English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic, etc; Display real-time waveform, harmonic ratio bar charts of current voltage; Dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data.
-
Product
AC Load Bank (Resistive & Inductive)
K-1000 Resistive & Inductive
-
Kongter Test & Measurement Co., Limited
Kongter resistive & inductive AC load banks are used to simulate the motor loads or other electromagnetic devices working at their rated power factor. Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Using a resistive & reactive load bank enables comprehensive testing from a single unit.
-
Product
Peak and Average Power Sensors
E9320 Series
-
- Operates with the EPM-P series and P-Series power meters- 300 kHz, 1.5 MHz and 5 MHz video (modulation) bandwidths- Provides peak and average power measurements- Calibration factors stored in EEPROM- Fast measurement speed over the GPIB (up to 1,000 readings per second)- Two frequency ranges: 50 MHz to 6 GHz, and 50 MHz to 18 GHz- Wide dynamic range sensors
-
Product
PWM Type AC Power Supply
LSP-5KVA
-
• Circuit Type: (IGBT) MPWM Pulse Duration Modulation • Input: 1 Phase 220V±10%, 50Hz/60Hz±5% • Output Voltage: HIGH/LOW Adjustable 1)1 Phase Voltage Range: (HIGH)0~300V, (LOW)0~150V 2) Nominal Voltage: +10%~+25%, -10%~-30% • Output Frequency: 50Hz, 60Hz, adjustable between 45 and 70 Hz, 400Hz • Load Voltage Stabilization Rate: ≦0.5% • Frequency Stabilization Rate: 0. 1% (Fix Point 50Hz, 60Hz and 400Hz) • Wave Distortion Rate: ≦2% (Resistor Load); Efficiency: ≧85% • Output Instruments: Frequency Indicator, 4-digits RMS digital frequency indicator, resolution is 0.1Hz Voltage Meter, 4-digits RMS digital voltage meter, resolution 0.1V Ampere Meter, 4-digist RMS digital ampere meter, resolution 1Ma Power Indicator, 4-digits RMS digital power indicator, resolution 1W Power Factor Meter Resolution 0.001 • Protective Devices: Over load, short circuit, over voltage, over current, over temperature protective and alarm devices • Operating Environment: Temperature 0~40℃ Relative Humidity 0~90%
-
Product
Resistive & Capacitive AC Load Bank
RCD
-
RCD AC load banks are used to test the REAL working condition of UPS, rectifier, inverter and etc who are loaded by non-linear or electronic load with non-constant resistance such as computer, networking equipments and etc. Through the accurate detection of its output and power quality, users could avoid the inadequate loading capacity or cause pollution to power grid, so as to guarantee supply security. JUNXY RCD load banks leading power factor loads are created to debug power supply system parameters such as its crest factor test.
-
Product
High Voltage Capacitor Batteries
-
Lifasa - International Capacitors, SA
There are a series of elements and materials, just like in the BT equipment, for their operation in AT and that must accompany our AT capacitors for the proper functioning of these and for our installation / network, as well as the rest of equipment that compose it and that are in operation in parallel to the capacitor / s that we want to put into service for the correction of the power factor (compensation of the consumption of reactive energy).
-
Product
AC Line Harmonics Analyzer Including Flicker Analysis With UK, Schuko Or US Socket.
HA1600A
-
Compliance quality measurements to EN61000-3-2 and EN61000-3-3Measures peak or rms voltage or current, real or apparent power, power factor, phase etc.Tabular/histogram of 40 harmonicsVoltage/current waveforms displaysContinuous analysis with real-time graphical updateWide range of power connectors available320 x 240 pixel high-contrast displayUSB, RS232 and printer interfaces fittedPC control and documentation software supplied (HA-PC-Link+)
-
Product
Automatic Battery
BATM
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage instalations.




























