Showing results: 76 - 90 of 156 items found.
-
TX-205 -
Neutronics Manufacturing Co.
NMC's Digital tap position indicators, Type: TX-205 Are instruments used to indicate the tap position of the power transformers with OLTC. TX-205 Comes With 4-20mA Single / Double output for SCADA systems.
-
AE-150 -
ndb Technologies Inc.
The AE-150 is designed to detect and localize Partial Discharge activity inside oil-insulated power transformers. This instrument is a powerful diagnostic tool that combines electric and acoustic sensing technologies to perform partial discharge pinpointing.
-
HDLT -
Hention Electrical Equipment Co., Ltd.
This integrated precious insulation oil dielectric loss tester is for measuring dielectric loss TAN and capacitance of transformer insulation oil.This is a high precision instrument; integrated with oil cup, temperature control instrument, temperature sensor, dielectric loss test bridge, AC test power, and standard capacitor, etc.
-
RMO TW Series -
Amperis sl
The RMO-TW instrument can perform a simple, fast and reliable verification of a transformer on-load tap changer. This instrument allows measurements of a winding resistance at each tapping position of an on-load tap changer without discharging between tests. Problems with OLTC switching, such as interruption, can be detected with these measurements. The results are displayed on a backlit LCD screen.
-
Series FT -
GE Digital Energy
An industry standard for CT & VT isolationfor instrument transformer and connected device testing.Up to 10 poles; Numerous configurations availableTypically mounted on switchgear and relay panels10 pole test plug available; UL and cUL recognized.
-
Voltage and Current -
The Eastern Specialty Company
Testing and calibrating instrument transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. The burden sets described below have been carefully designed to meet these requirements.
-
TWR-H Series -
IBEKO Power AB
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.
-
AD-7010 -
ADEX Urzadzenia Pomiarowe
AD-7010 instrument is designed to measure, with high accuracy, the resistance of conductive elements power equipment: motor windings, transformer windings, conductor rails, inspecting the electrical conductivity of bolted joints, crimped, welded, the contacts of switches and relays.
-
TAP4 -
Zensol Automation Inc.
The TAP-4 is the first instrument to use vibro-acoustic measurement to perform tests on On-Load Tap Changers (OLTC). The TAP-4 is a universal device, it adapts itself to any type of transformers: MR Reinhausen, ABB, Ferranti, Federal Pioneer and others.
-
Weshine Electric Manufacturing Co., Ltd
Our multifunction Transformer Test Bench (VS-ZHSY Series) is intuitive with all of the ease of working with individual, dedicated instruments. We deliver this experience through our design philosophy. Rather than producing a single, complex system with afterthought towards rendering it friendly, we uniquely combine several intelligent instruments packaged as a single system.
-
HVA28 -
HV Diagnostics Inc.
The HVA28 is the smallest, lightest VLF/DC test instrument on the market. It is about as small as you can make it! Do not let its compact size lead you to believe this unit is lacking in power. The instrument can test up to 100,000ft/30kms of cable (at reduced voltage and frequency). In addition to cables, this unit can test vacuum bottles, transformers, motors / generators, cable sheath/shields, etc.
-
Yangzhou Power Electric Co., Ltd
The test system is used to do AC voltage withstand test and PD measurement for high voltage insulation products, combined electrical equipment, instrument transformers, etc.
-
AD-7110 -
ADEX Urzadzenia Pomiarowe
The instrument AD-7110 is designed to measure, with high accuracy, resistance conductive elements of power devices: motor windings, transformer windings, conductor rails, inspecting the electrical conductivity of screw connections, crimp, welded state of the contacts of switches and relays current up to 100 A .
-
Power Diagnostix Systems GmbH
Partial discharge monitoring systems can be used for permanent surveillance of insulation systems on GIS, transformers, rotating machines, motors, cables, or other high voltage equipment. These instruments are designed for long term data recording, alarm handling, event recognition, and system integration.
-
Technology Products
The ART-3D series of Automatic Ratio Testers are precision instruments, designed to measure the turn ratios, phase displacements, excitation currents of single phase and three phase power, distribution and instrument transformers in conformity to the IEEE C57.12.90 & IEC 60076. Now featuring an enhanced test lead design, the ART-3D is the perfect instrument for real-life field usage. ART-3D series also has Anti Induction circuit which makes it suitable for system voltages upto 765KV.