Coil Turns
See Also: Coil, Helmholtz Coils, Rogowski
-
Product
TOROIDAL COIL TURNS TESTER
TURNS-TTPT
-
Digital TURNS TESTER for Counting Number of Turns for Toroidal Coils , Current Sensor , Current Transformer , Round Core Coils. Can measure, Turns along with Winding Polarity and DC Resistance.Turns Measurement ( through Toroidal Turns Test Platform) : -> TTPT-100 : 5 Turns ~ 1000Turns-> TTPT-1000 : 500 Turns ~ 10,000Turns
-
Product
WINDING COIL TURNS TESTER
VE201R
-
Winding Turns Tester for Counting Measuring Number of Turns for Air Core Coils, Bobbin Coils or Solenoid Coils. Can Measure : Turns along with Winding Polarity and DC Resistance.Turns Measurement : 1 Turns to 80,000 Turns
-
Product
Bobbin Winding Coil Turns Tester
SS108A series
-
Bobbin winding coil testers are used to test various coil of turns. Such as: generator winding turns, transformer winding turns, motor winding turns, inductor winding turns, contactor winding turns, relay winding turns, sparking winding turns, ignition winding turns, speaker voice coil, etc.
-
Product
Solenoid Valve Tester
DZ800
-
Shanghai Aoboor Electric Co., Ltd.
Insulation resistance, HIPOT, coil DC resistance, turn to turn surge tests can be automatically completed in one time. Applicable to electrical performance test of solenoid valves, changeover valves
-
Product
DIGITAL TURNS TESTER AND DIGITAL LCRTZ METER
TURNS-LCRTZ
-
Digital TURNS TESTER with LCR for Counting / Measuring Number of Turns for Toroidal Coils , Current Sensor , Current Transformer , Round Core Coils. Can measure, Turns along with Winding Polarity , DC Resistance , Inductance (L), Capacitance (C), DC Resistance, Rac, Q, D, ESR and Tan.Toroidal Turns Platforms :TTPT100 : 5 T - 1000 T , TTPT1000 : 500T-10000 T The Platform has 2 connections for the coil and 2 for the probe wire. Measurement principle is based on dynamic comparison of the voltage across one turn and the coil. You will be able to get the polarity or winding indication with respect to the one turn reference.Accuracy : + 0.2% + 0.5T for high and medium permeability cores at suitable test frequency. Internal Diameter must be able to pass a wire as thin as 0.2 mm. External Diameter as high as 200 mm.Test Frequency Selectable in Step : 50 Hz, 100 Hz , 500 Hz, 1 KHz, 5 KHz, 10 KHz. Test Voltage adjustable : 100mV to 1V in steps of 50mV.
-
Product
High Voltage Surge Current Monitors
HVSCM
-
Designed to be used with the Model HVST High Voltage Surge tester. The Surge Current Monitor allows simultaneously surge testing 20 units. The Surge Current Monitor monitors the current going through each unit under test at the time of the surge. If a unit under test breaks down or leaks, the Surge Current Monitor will identify the bad unit by lighting the corresponding LED. The most important features of the surge tester are its ability to test the entire winding insulation system. A high voltage surge generates turn to turn, coil to coil, and phase to phase voltage stress, as well as ground insulation stress. When used as a dielectric test, accurate voltage readings are essential. The HV Surge Tester monitors the voltage directly across the winding under test. In production testing we expect that most of the time the devices will pass. In the event that one should fail, the failed device would be removed and then all the parts would have ot undergo another surge test. Since most devices pass most of the time, simultaneous surge testing can be a real time saver.
-
Product
Bobbin Winding Coil Turn Tester
SS108 Series
-
This (SS108** series) winding coil turn testers are used for testing turn of various coils without core, like as: generator winding, transformer winding, relay, inductor, contactor, ignition coil, voice coil, etc.
-
Product
Helmholtz Coils / Radiating Loops
-
Formed by a pair of conducting circular coils with many turns, each carrying a current. The coils are separated by a distance equal to the radius of the circular loops.
-
Product
High Voltage Surge Testers
HVST
-
The most important features of the surge tester are its ability to test the entire winding insulation system. A high voltage surge generates turn to turn, coil to coil, and phase to phase voltage stress, as well as ground insulation stress. When used as a dielectric test, accurate voltage readings are essential. The HV Surge Tester monitors the voltage directly across the winding under test. This voltage is displayed on an oscilloscope and recorded on the Pass/ Fail LED latch monitor. This voltage will be accurate despite the impedance of the winding being tested. The insulation system can be tested way above the operating voltage because of the brief duration of the applied voltage test pulse. This allows faults to be detected long before they become apparent at operating conditions.
-
Product
Toroid Core Coil Turns Testers
SS107A
-
The magnetic torrid ring core winding coil turns tester (SS107A) adopts the high speed center microprocessing unit circuits and precise measurement A/D circuits. This coil turns tester is used to count the coil turns of various torrid core winding coils. Like as: torrid core inductors, torrid core transformers, torrid core sensors, wate meter sensors, torrid current transformers, torrid core choke coils, etc. The tone tester is named magnetic ring core coil turn tester also.
-
Product
Helmholtz Coils
-
Helmholtz-Coils are especially designed to generate precisely defined magnetic fields from DC to the upper end of the audio frequency range and beyond. The generated fields are in a strongly linear relation to the coil current. The field- strength can be calculated exactly by analytical (or numerical) methods, based on the coils' geometry, the number of turns and the coil current.
-
Product
Turning Mirror
10769A
Plane Mirror
The 10769A is ideal for use in laser measurement and calibration applications. In the calibration of slant bed lathes, for example, the beam steering mirror deflects the beam from the laser head upward, through the interferometer, along the lathe's cross slide. One or more mirrors can also create a path from a laser head to an interferometer located in an otherwise inaccessible position, as in the case of a milling machine with a table that moves in only one axis.
-
Product
High-Frequency Test Coil
-
West Coast Custom Designs, LLC
is most commonly used by the neon industry for detecting leaks in a pumping system; the spark generated by the coil via the solid tip, will enter the tube through the leak and become bright white at the point at which it enters.
-
Product
Standard Helmholtz Coils
-
Helmholtz Coils are ideal for the measurement of Rare Earth (Samarium Cobalt, Neodymium) and Hard Ferrite permanent magnet materials (materials which exhibit a relative straight line demagnetization). Our standard Helmholtz Coils are for use with fluxmeters. The Helmholtz Coil measures the magnet sample as a single magnetic moment provided that the longest dimension of the magnet sample is less than one-third (1/3) the diameter of the coil system. By definition, the magnetic moment per unit volume is the intrinsic magnetization of the sample. With our calibrated Helmholtz Coil and Integrated Fluxmeter – and given the volume of the permanent magnet sample – the intrinsic open circuit operating B (Bdi) can be measured.
-
Product
Turned Log Peri Antenna
MOLP80-1000M
-
This is Antenna for IEC61000-4-3 Radiation Immunity Test. Unique Structure with turned Element increase the GAIN at the low frequency. Stew structure of 22 and can be fitted to normal Antenna MAST.
-
Product
Shorted Turns Tester for Bobbin Wound Coils
Model STT-4
-
International Electro-Magnetics, Inc.
The STT-4 Shorted Turns Tester offers a quick and easy means to detect shorted turns in bobbin coils. It is a non-stress and non-contact test.
-
Product
Potential Measuring Coils
-
measure the magnetic potential of magnets, magnet systems and their surroundings.
-
Product
CDI Ignition Coil
-
An on-plug coil for use with Capacitive Discharge Ignition (CDI). Design and manufacture is in-house, so we can make the coil to suit your specific application. The information given here is for a typical coil. Many of the parameters can be tailored to a particular installation.
-
Product
Transformer Turn Ratio Meter
-
A specialized, highly accurate diagnostic instrument used to measure the ratio of primary to secondary winding turns in transformers.
-
Product
3 Phase Choke Coils
-
Supreme Instrument Laboratories
Suitable for operation on 415 / 440 V, A.C. 50 Hz. Working on air gap separation by increasing / decreasing the air gap with the help of a hand wheel mechanism, mounted on thick wooden / bakelite sheet with castor wheels for easy transportation.
-
Product
Transformer Turns Ratio Meters
-
Vanguard Instruments Company, Inc.
The ATRT-01 S3 is Vanguard’s fourth generation, micro-processor based, single phase, automatic transformer turns-ratio tester. The ATRT-01 S3 uses the IEEE C57.12.90 measuring method to determine the transformer turns-ratio. The transformer turns-ratio is determined by precisely measuring the voltages across the unloaded transformer windings. The ATRT-01 S3’s measuring circuitry self adjusts before each measurement to ensure turns-ratio accuracy. Two selectable test voltages, 4Vac and 40Vac, offer flexibility in testing different types of transformers.
-
Product
Search Coils And Field Measuring Coils
-
Designed to measure the magnetic flux on magnets or in the airgap of magnet systems.
-
Product
Rogowski Coil
-
A Rogowski coil produces a voltage output based on the rate of change of the current input. The absence of magnetic core ensures low inductance and comes with no saturation, resulting with a fast response and no inserted losses.
-
Product
Turns Ratio Testers
TRT Advanced Series
-
TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.
-
Product
Turns Ratio Testers
TRT Standard Series
-
When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.
-
Product
RF Helmholtz Coil
-
The Beehive Electronics 135A RF Helmholtz coil generates a well-controlled, uniform magnetic field. It can be used to calibrate magnetic field probes, such as the Beehive 100 series, or for testing the susceptibility of other devices to magnetic fields. The Helmholtz coil comes supplied with a fixture that makes it easy to calibrate Beehive 100 series probes.
-
Product
Turns Counter for Bobbin Coils
TC-5 / TC-5A
-
International Electro-Magnetics, Inc.
The TC-5 is designed to verify the turns count of bobbin or free wound coils. When calibrated with a "Production Standard" coil, the TC-5 can measure to an accuracy of 99.9% or 1 turn in 1,000 for coils of less than 10,000 turns.
-
Product
T3RC Rogowski Coil Current Probes
T3RC Series
-
Teledyne Test Tools Rogowski Current probes offer a broad range of products covering a wide frequency span and current measurement ranges for maximum application coverage whilst being easy to use in difficult to reach parts of the circuit.
-
Product
Turning Mirror on Universal Mount
10769B
Plane Mirror
The Keysight 10769B Turning Mirror on Universal Mount deflects a laser beam at any angle, in either the vertical or the horizontal polarization plane of the beam. The 10769B contains the same turning mirror as the 10769A, but has a different mounting.
-
Product
Circular Helmholtz Coils
-
Helmholtz-Coils are especially designed to generate precisely defined magnetic fields from DC to the upper end of the audio frequency range and beyond. The generated fields are in a strongly linear relation to the coil current. The field- strength can be calculated exactly by analytical (or numerical) methods, based on the coils' geometry, the number of turns and the coil current.