  • Rogowski AC Current Probe, 23 MHz, 3000 A

    N7040A - Keysight Technologies

    The Keysight N7040A Rogowski coil current probe is designed for measuring AC currents up to 3,000 A with the bandwidth ranging from 3 Hz to 23 MHz. The probe is easy to use because it has a thin, lightweight, flexible and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult to reach parts and confined spaces of a circuit under test. It can also measure large AC current without increase in transducer size.

  • sbRIO-9425, Non-Enclosed, 24 V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

    783950-01 - NI

    Non-Enclosed, 24 V, 32-Channel (Sinking Input), 7 µs C Series Digital Module - The sbRIO‑9425 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each digital input line is compatible with 24 V logic levels. The sbRIO‑9425 offers isolation between the input and output banks from channel‑to‑earth ground. Non-enclosed modules are designed for OEM applications.

  • Load Cell Transmitter

    MODEL SST-HV - Transducer Techniques, Inc

    The SST-HV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-HV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-HV may be powered from 95-240 Vac ±10%. The SST-HV has an Isolated transducer excitation output that is selectable between 5Vdc or 10Vdc. There are Dual solid state relays and an Isolated 4-20 mA, 0-20 mA or 0-10V analog output. There are three Isolated serial data transmitter output ( RS232 , Half-duplex RS485, full-duplex RS485 ) and three serial protocols that are software selectable (Modbus RTU, Modbus ASCII and Custom ASCII). Isolation to 250V rms is provided for power, signal input, analog output, relay outputs, and communications. Isolation adds safety and avoids possible ground loops. The transducer excitation output is isolated to 50V from signal ground.

  • 6000 Series Analog I/O Modules

    Pacific Instruments, Inc.

    Series 6000 analog I/O modules condition, amplify, filter and digitize signals from virtually any transducer. All modules have conditioning & amplifier per channel and nearly all modules allow for setting bridge completion, shunt calibration, transducer power, gain, etc. individually per channel. Following the conditioning/amplifier stage, multi-pole Bessel or Butterworth analog filters are provided on each channel and can be set or bypassed individually by program control. A number of the modules include a high level analog output providing a conditioned/filtered output to a redundant, external A/D system. A 16-Bit Successive Approximation A/D follows the analog filter stage. Some modules use a single A/D with sample and hold while others have an A/D per channel. Sample rates are programmable per channel to easily accommodate mixing high and low speed measurements into a single data stream. Programmable hardware based warnings and alarms are included in the channel-by-channel architecture and are detected by digital output modules in the system, providing an ultra-low latency control capability directly from the data acquisition system.

  • Load Cell Transmitter

    MODEL SST-LV - Transducer Techniques, Inc

    The SST-LV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-LV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-LV may be powered from 12-30 Vac or 10-48 Vdc. The SST-HV Has an Isolated transducer excitation output that is selectable between 5Vdc or 10Vdc. There are Dual solid state relays and an Isolated 4-20 mA, 0-20 mA or 0-10V analog output. There are three Isolated serial data transmitter output ( RS232 , Half-duplex RS485, full-duplex RS485 ) and three serial protocols that are software selectable (Modbus RTU, Modbus ASCII and Custom ASCII). Isolation to 250V rms is provided for power, signal input, analog output, relay outputs, and communications. Isolation adds safety and avoids possible ground loops. The transducer excitation output is isolated to 50V from signal ground.

  • Drop-Through Load Cells

    Instron

    Instron load cells are an integral part of the load weighing system of a testing machine. Their interchangeability along with transducer recognition and single point electrical calibration makes them easy to use. They maintain high alignment and are resistant to offset loading throughout the test, even with large sized specimens. Instron controls the design, manufacture and quality of all load cells, with customer applications in mind. They are certified in accordance with international standards for use in material testing machines only.

  • Probes For Non-Contact Ultrasonic Testing

    SONOSCAN CFC / CF - SONOTEC GmbH

    Due to the strong damping properties of air, low frequencies in the kHz range are used in air-coupled ultrasonic testing. It is therefore all the more important that the ultrasonic transducers offer a particularly high sensitivity in order to ensure high penetration and improved resolution. We achieve this, among other things, by installing preamplifiers in the receiver probe as well as by using our own Piezocomposite Technology, which enables a flexible use of the matching materials in our CFC and CF probes.

  • Sonar Transponder Module for Gavia AUV

    Teledyne Marine Gavia ehf.

    ​THE SONAR TRANSPONDER MODULE (STM), is a module for receiving and retransmitting sonar signals which allows for a standard Gavia vehicle to be configured as a Sonar Training Target (STT) for ASW training purposes. The STM consist of a flooded transducer compartment, an electronic compartment and a hydrophone that is towed behind the Gavia AUV and is capable of simulating preprogrammed target characteristics. The STM is programmable to emulate different type of realistic submarine target sizes and speeds for cost effective and re-usable ASW training capability.

  • Din Rail Load Cell Amplifier (user selectable gain)

    SY038 - Synectic Electronics

    The SY038 is a strain gauge bridge amplifier ideal for use in load cell amplification.  This Load Cell Amplifier has a variable gain functionality using a miniature dip switch which enables the user to select one of 16 ranges for transducer outputs as low as 0.25mV/V and up to 4.4mV/V, higher if specified.  It has the best stability in its class and high immunity to interference.  Non-interactive Zero and Span trimmers are screw driver adjustable giving a further +/-20% adjustment.

  • Digital LVDT sensor ZET 7111-L

    ZETLAB Company

    ZET 7111-L is a digital LVDT displacement sensor. It requires no special adjustment and starts measuring right after power is on. Displacement measured values are transferred in digital form via CAN interface. The LVDT digital sensor consists of a primary transducer (LVDT sensor) and a measuring element (ZET 7111-L unit). The LVDT sensor converts meaured object (to which it is mechanically connected) linear displacement  into electric signal to be further transferred into displacement values by the measurement module.

  • Humidity Sensors

    Sencera Co.

    Humidity sensors can have analog, digital or video type displays and can have a number of different form factors. They can be PCB-mount devices, standard sensors or transducers, or a simple gauge or indicator. They can also be various types of instruments, whether handheld, benchtop or mounted.In addition to pressure and temperature compensation, humidity sensors can have a number of features to make them more useful or easier to use. Humidity sensors can include data logging, event triggering, self-testing, self-calibration, and battery power.

  • High Accuracy AC Reference Source

    515 - Clarke-Hess Communications Research

    The Model 515 High Accuracy AC Reference Generator fills a need for a relatively low cost and practical solution for supplying a reference excitation to typical LVDT and Synchro/Resolver transducers. The Model 515 has built-in load sensing which, in effect, yields "zero" output impedance and virtually eliminates the effects of fluctuating output loads. With up to 15 VA of output into loads with as much as 80 of phase shift, the Model 515 is ideally suited to driving inductive loads.

  • Crack Opening Displacement (COD) gauges

    COD - Instron

    Instron® Crack Opening Displacement transducers are designed specifically to perform standard ASTM and ISO fracture mechanics tests (both cyclic and static), covering all common specimen geometries (CT, SEB, Centre Crack, Arc Shaped). Each model offers class leading linearity, whilst being rugged enough to withstand the high energy release common in many of these applications and can be used at both elevated and sub-ambient temperatures. These gauges comply with requirements laid down in ASTM E399-09.

  • S-Beam Static Load Cells

    2519 Series - Instron

    The 2519-xxxN Series load cells are specifically designed for use with 3300 single column testing systems. Automatic transducer recognition and electrical calibration makes them easy to use. The load cells incorporate overload protection and can withstand loads up to 150% of their force capacity without damage and 300% without mechanical failure. The load cells allow the user to zero out the tare weight of a grip or fixture that weighs up to 40% of the force capacity, while still maintaining the full specified accuracy.

  • Dual Pitot Tube Flow Meter

    PTFM-ONE-DT - HORIBA, Ltd.

    The Dual Pitot Tube Flow Meter, PTFM-ONE DT is a standalone interface for measuring exhaust gas flow rate of combustion engines. The system uses the tried-and-tested pitot tube principle with high-frequency transducers, with a sampling rate of 1kHz to accurately measure highly pulsating exhaust flows. This rapid capture rate ensures that any pulsations or exotic behaviour caused by the engine is measured, and the unique design of the PTFM-ONE DT means reverse flows can be calculated, with the same guarantee of sensitivity.