Product
15 Amp 120 VAC Filter and Surge Arrestor
AS-AC15
-
- 15 amp 120VAC quad outlet for high power devices- Resettable circuit breaker protection, easy to use and reset- I EA standard input plug and #14 GA AC line cord for USA - standard interface- MOV surge arrestors included - for even more protection- High level of common mode and differential mode filtering digital noise and RF filtering eliminates- digital artifacts and RF interference - See chart- Front Panel Neon Blue AC ON indicator - just plain cool to look at, not too bright!- Double shielded box inside - for optimum filtering operation- Size 6W X 4H X 4 3/4 D in inches approx 3 lbs
-
Product
Voltage Detectors
JSC
-
The JSC family of devices provides a highly reliable way to determine if voltage is present downstream of the disconnector or circuit breaker knives during zero-energy shutdowns. They dramatically increase the safety of personnel performing maintenance on electrical equipment. When voltage is present downstream of the disconnector knives, one or more LEDs on the JSC-88A will remain illuminated. The JSC's compact design allows for direct installation on the disconnector door, starter, or control panel.
-
Product
24 V DC Power Supplies
-
*Space-saving design*High power reserves*Low heating of the control cabinet*Low inrush current*Safe switch-off by circuit breakers in case of short circuit
-
Product
DC Hipot Test Set
KVZG
-
KV Hipot Power Test Equipment Co.,Ltd
DC Hipot Tester is applied to measure output voltage and leakage current for zinc oxide arresters, magnetic blowing arresters, power cables, generators, transformers, circuit breakers and other equipment.
-
Product
10 A portable digital micro-ohmmeter
MPK-253
-
The MPK-253 digital very low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of switches and circuit breaker contacts, transformer and motor windings, wire and cable samples, joints in busbars, etc., using test currents from 1mA up to 10 A.
-
Product
Circuit Breaker Time Interval Meter
-
Measuring contact timings is useful for finding the contact bounces and non-simultaneity of contacts. This helps in finding the possible electrical or mechanical defects in the circuit breaker contacts. Timing analysis also make it possible to detect incorrect mechanical adjustments and wear phenomena of the circuit breaker by measuring the differences between the fastest and slowest phases.
-
Product
HV DC Test Set
RX30/4P
-
K&S Engineering and Scientific Ltd
The output is continuously variable from zero to 10 kV by means of the panel mounted regulator. An output trip is fitted which operates when the output exceeds 25 mA switches off the test set and operates a neon overload indicator. Primary protection is provided by two panel mounted fuses. The output is protected by the output trip and a magnetic/hydraulic circuit breaker.
-
Product
Circuit Breaker Testing Equipment (SCOT Series)
SCOT MXP+
-
SCOT MXP+ measures, displays and prints CLOSE, OPEN and CLOSE-OPEN time of 2 Main + 2 PIR contacts per pole, 3 poles simultaneously, ensuring measurement of 6 Main + 6 PIR contacts simultaneously. Ideally suitable for CBs having PIR contacts & multiple breaks per pole
-
Product
Contact Resistance Meter
CRM 200B+
-
CRM directly measures micro-ohm values at 200A DC under live EHV switchyard conditions quickly & accurately. It is specially designed to reliably measure micro-ohm contact resistances of Circuit Breakers, Isolators, Busbar joints, earth switch joints, welded joints etc., under the hostile electrostatic noise found in live EHV switchyards up-to 765 kV. SCOPE’s ability to make electronics work in such environment enables CRM to measure mili-volts signal in the presence of kilo-volts noise.
-
Product
Low Resistance Ohmmeters
-
Some times know as Ducter testers, these are highly accurate, easy to operate instruments that measure resistance with resolution as fine as 0.1 micro-ohm. Digital micro-ohmeters and DLROs measure contact resistance of switch and circuit breakers, aircraft frame bonds, and rail and pipeline bonds just to name a few of the applications. Megger has models available for testing using test currents from 0.5 mA to 200 amps covering a multitude of applications that require precise low-resistance measurements.
-
Product
Safe Isolation & Lockout Tagout
-
Our range of Safe Isolation Kits and and our NEW lockout devices for isolating circuit breakers, RCD's and MCCB's, enable you to work safely on installations, following the safe isolation procedure, without the risk of electric shock. All our devices and equipment are easy to use and all equipment is supplied with Lockout Tags to identify the device is locked and who to contact in the event of an emergency.
-
Product
AC / DC Electronic Loads – Benchtop Testing to Automated Test Systems
-
Chroma Systems Solutions, Inc.
Chroma is the global leader in Electronic Load manufacturing. Chroma’s AC Electronic Loads are designed for testing uninterruptible power supplies(UPS), Off-Grid Inverters, AC sources, and other power devices such as switches, circuit breakers, fuses and connectors. Chroma’s DC Electronic Loads are used for power testing in all markets including automatic test systems, LED, power supply testing, battery testing, and fuel cell testing. Chroma loads can do it all including full current down to 0.4VDC, CZ mode, user defined waveforms, timing measurements, and 3 current ranges per load. Chroma’s electronic loads come standard with either USB or RS232 ports for control and can be configured for GPIB (IEEE-488) control as well.
-
Product
Ground Grid Tester
GGT Series
-
The GGT500 ground grid integrity tester is designed for inspection of the substation ground grid. It can also be used as a portable micro-ohmmeter with Both Sides Grounded and Remote Control functionalities. It is intended to inspection the conditions of a grounding system beneath substations, testing of medium- and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links.In the United States when inspecting the quality of the grounding systems beneath a substation, the proper procedure is to inject 300 A DC during a time period of 60 s. This is what the GGT500 will do, and in that time period, the current path and voltage drop are checked. Also acting as a micro-ohmmeter, the GGT500 can test low resistance values by producing high test currents of up to 500 A.The instrument is placed in an unbreakable, plastic case with IP67 protective rating (with closed lid). Although very portable and lightweight, micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents, as well as the use of thinner/longer test cables. GGT500 ground grid integrity tester generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. This significantly decreases magnetic transients and ensures great accuracy.When used for testing in Both Sides Grounded conditions, a special current clamp powered from the ground grid integrity tester is used for measuring a current through groundings. If even a higher safety level is required, the remote control feature enables the operator to perform measurements from a distant location, away from the instrument and test object.
-
Product
Relay Test Equipment
-
Vanguard Instruments Company, Inc.
The VIC Model PCI-600 is a programmable, high-current source that is designed specifically for utility-substation applications. This alternating current(ac) test device is used primarily for injection testing of protective relays. This same device can also be used for testing thermal, magnetic and solid-state motor-protection relays and molded-case circuit breakers. The PCI-600 is versatile and can also be used in many other applications that require a high-current source.
-
Product
Turn-Key Short Circuit Laboratories
-
For low and medium voltage switchgear including :*Circuit breakers*Contactors*Disconnect switches*Fuses*Miniature circuit breakersApplied tests for low and medium voltage switchgear :*Dielectric withstand test*Impulse withstand test*Breaking capacity test*Mechanical life testElectrical life test*Over load performance test*Short circuit breaking capacity test**Short time short circuit impulse current test*Temperature rise test*Operation performance testTests for low & medium voltage panels :*Short time short circuit impulse current test*Dielectric test*Impulse withstand voltage test*Temperature rise test
-
Product
Circuit Breakers
-
As the premier supplier of power system components, Interpower has what you need to complete your projects, including circuit breakers. Interpower has no minimum order requirements, plus same day shipping is available on in-stock Interpower products.
-
Product
Transformer Rectifier Assemblies
-
Transformer rectifier assemblies are very useful in OEM applications when unregulated DC output is required. Input power can be single-phase or three phases. With single-phase input power, the output ripple is 50%. With three-phase input power, the output ripple is 5%. A 5% output ripple is a clear advantage. Hence, transformer rectifier assemblies with three-phase input power are more popular. Circuit breakers, fuses, voltmeters, and ammeters can be added per customer requirements. The assemblies can be an open frame or inside an indoor enclosure.
-
Product
Multiple Channel Burn In Power Supply
MCPS
-
The most important features of this burn in power supply is its ability to hold a constant output for each channel even in the event that a unit under test on one channel may short and fail. Since each channel has it''s own transformer, no glitches or voltage spikes can get into any of the other channels. This image shows the results as the second channel from the left is shorted with a small wire and the circuit breaker pops out. Used for burn-in testing and other timed testing where power isolation is required. Very basic simple circuit, see schematic below. Cleans and frees up benchtops, burn in racks and work space clutter. Available in benchtop or rackmount.
-
Product
Circuit Breaker Contact Resistance Meters
-
Vanguard Instruments Company, Inc.
The Vanguard Auto-Ohm 10 is a 10-ampere battery powered micro-ohmmeter designed for low-resistance-measuring applications such as the measurement of resistance in circuit breaker contacts, bushing contact joints, and welding joints. The unit is powered by four 3400mAh, 3.7Vdc Li-Ion rechargeable batteries. With these high capacity batteries, up to 2,900 tests per charge (10A/2 second duration) can be performed in the field.
-
Product
Circuit Breakers
-
Our broad portfolio of Hydraulic-Magnetic Circuit Breakers, Switches, GFCI/ELCI Modules, and Modular Distribution products, deliver consistent quality with a wide range of features, tailored solutions to meet your application.
-
Product
Iron Core Current Limiting Reactors
-
Current Limiting Reactor (CLR) is one of the most effective short circuit current limiting devices. It reduces stresses on busses, insulators, circuit breakers and other high voltage devices. Use of CLR is the most practical and economical approach at current limiting.
-
Product
Circuit Breaker Testing Equipment (SCOT Series)
SCOT MXP
-
SCOT MXP measures, displays and prints CLOSE, OPEN and CLOSE-OPEN time in various configurations. The MXP has a special mode to measure Pre-Insertion Resistor (PIR) closing time
-
Product
Contact Resistance Meter
-
The Motwane Manufacturing Company
High contact resistance values are a definite cause of the failure or less than optimal performance in a wide variety of electrical devices. Contact resistance testing is therefore most critical to measure the resistance of electrical connections in switching devices, circuit breakers, isolators, busbars, relays, joints, connectors, cables, and cable joints. The device helps to find destructive or corroded contacts and hence protects substation devices from damage.
-
Product
3-Phase AC Voltage Transducer
ENVIROMUX-PT3-600
-
Monitors and reports voltage of any 3 phase circuit. Remotely detect blown fuses or tripped circuit breakers. Three 600 VAC inputs, three 4-20 mA outputs. Inputs and outputs isolated from one another. Frequency: 50/60Hz. Maximum primary current: 600 volts. Accuracy: ±0.25% F.S. @60Hz. Output: 4-20 mA. "Zero" adjustment for accurate 0 VAC reading, and "Calibration" adjustment for frequency and voltage level. Powered by the ENVIROMUX-S420MA-24V. Regulatory approvals: UL, CUL, CE. Requires two ENVIROMUX-S420MA-24V to monitor three phases. Caution: installation should be performed by qualified electricians only. Make sure electrical service is disconnected before making any electrical connections.
-
Product
Lock Out Kit
LOKKIT1
-
The Martindale universal lock out kit is compatible with most circuit breakers. It is supplied with a padlock that has its own unique key, and a safety hasp that enables multiple users to lock off with space for up to 6 padlocks.
The full 16 piece kit includes: 1 x Padlock with unique key, 1 x Steel safety hasp with space for up to 6 padlocks, 1 x Green mini MCB lock, 1 x Yellow mini MCB lock, 1 x Blue medium MCB lock, 1 x Large red MCB lock, 1 x Small red MCB lock, 1 x Red fuse lockout breaker, 1 x Yellow fuse lockout breaker, 5 x Danger tags which can be overwritten, 1 x Black marker for writing on Danger tags, 1 x TC55 soft carry case
-
Product
Primary Current Injection Testers
-
Primary Current Injection Tester is designed for testing protective relay and circuit breakers and also testing the turns ratio of current transformers at high variable currents. A test current is injected into the primary side of a system to determine how the system behaves at particular levels of current. This test makes it possible to determine whether the relay will trip and how long the current needs to flow before the trip is initiated.
-
Product
Analyzers and Timers
CAT Advanced Series
-
Description The Advanced CAT Series Analyzers and Timers are stand-alone or PC-controlled digital instruments for circuit breaker status evaluation. Timing channels record arc closing and opening, resistance and auxiliary contacts. The main contact channels can also measure the resistance value of pre-insertion resistors (if present in the breaker). The advanced CAT series records graphs of the opening and closing coil currents and the movements of the moving parts of the high and medium voltage circuit breaker. Test results are printed on the 112 mm (4.4 inch) thermal printer (optional accessory) in tabular and graphical form. The advanced CAT series provides easy selection of different operating modes:
-
Product
Switch Analyser
SA10A
-
It has a built-in micro Ohm meter/Ductor for measuring of static and dynamic resistance of the breaker poles. It only weighs 11,6 kg. The versatility and precision that this unit offers is, without question unchallenged, and it will indeed be your best partner when testing circuit breakers. Tests in areas with high induction at known problematic substations has proven the SA10A to be the only circuit breaker timer that could withstand these extreme conditions. It's rugged, it's small and highly appreciated by our customers.
-
Product
6 Contacts- Circuit Breaker Analyzer
CB14
-
The CB14 is a 6 contacts circuit breaker analyzer designed to perform Timing, Motion as well as Static & Dynamic Resistance Measurement (DRM) in a single test. It also includes 3 multifunction analog inputs.
-
Product
Circuit Breaker Analyzers & Timers
CAT Handheld Series
-
When it’s not practical to use conventional robust circuit breaker analyzers, a handheld circuit breaker analyzer and timer may come handy. DV Power has developed a unique CAT Handheld series. It is specially designed for testing of circuit breakers with one break per phase. Their compact and ergonomic design can provide a wide range of features and reliable operations in low, medium and high-voltage substations or in industrial environments.CAT Handheld series consists of two models, CAT-P and CAT-H. Both of them have a large (5,7 in) colored touch screen display. Because of that, test results are visible in dark places as well as in bright sunlight.Powerful internal Li-Ion battery of the instruments can last up to 8 hours of testing without recharging.CAT Handheld series records:main contacts operating times,contact synchronization,sequence time,a resistance of pre-insertion resistors,open and close coil currents,main contacts bounce time,auxiliary contact time,DC Voltage.Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by triggering signal from current clamps connected to circuit breaker coil.CAT-H is capable of performing a coil control, while this feature is optional at CAT-P instrument. In contrast to CAT-H, CAT-P instrument can execute “First Trip” test.Both instruments display numerical and graphical results. Because of that, a user can easily overlay up to 4 records in the graphical form and make a quick on-site analysis of potential defects.A user can download test results to a PC via Bluetooth interface for more detailed analysis using DV Win software.