Filter Results By:

Products

Applications

Manufacturers

Showing results: 871 - 885 of 1178 items found.

  • Sound Level Calibrator

    TM 100 - Kusam Electrical Industries Limited

    • Standard : Confirms to IEC 942 Class 1.• Output Sound Level : 94dB and 114dB under reference.• Accuracy : ±0.3dB (20°C, 760 mm Hg)• Frequency of 1000 ± 0.1% Hz allows calibration with A / B / C or D weighting networks or linear.• Low Battery Indicator (LED).- Operating Temperature range : -10 ~ +50 C- Storage Temperature range : -40 ~ +65 C (with batteries removed).- Temperature Coefficient : 0 ~ 0.01 dB / C• Calibration of “1 and ½” ceramic microphones.• Altitude Effects : Approx. 0.1 dB decrease for each 2000 feet increase in altitude fromsea level to 12,000 feet elevation, or comparable atmospheric pressure change(approx. every 50 mm of Hg decrease).• Battery : Single 9V transistor Battery. (NEDA 1604)• Battery Life : Approx 100 hours.• Dimension : 48 x 48 x 138mm

  • Isolation Measurement System

    DM-8000H - IWATSU Electronic Co., Ltd.

    *The input block, control block and display block are isolated with optical fiber cables. (DM-900A/AL, DM-910A/AL)*Frequency bandwidth: DC to 500MHz.*Simultaneous multi-channel measurement of many channels of different reference potentials. (2 to 24 channels) (DM-900A/AL)*Long-life battery drive. (The system can be driven by three batteries for about 12 hours) (DM-900A/AL, DM-910A/AL)*Measurement using long memory. (DM-900A/AL, DM-910A/AL)*Simultaneous measurements of the inverter's switching waveform and ON-voltage. (DM-910A/AL)

  • Pressure Calibrators

    AMETEK Sensors, Test & Calibration

    Our pressure calibrators offer a wide variety of features, accuracies, and pressure ranges. Included are intrinsically safe percent of reading calibrators, reference data recorders, wide-range dual sensor calibrators, and calibrators with built in pressure pumps. Many of our calibrators also offer current measurement, voltage measurement, 24 volt loop power supplies, and even complete systems with pressure pumps and calibration software. In many cases, one handheld calibrator can replace multiple instruments, reducing ongoing recalibration and maintenance costs.

  • PXI Vector Signal Transceiver

    NI

    The PXI Vector Signal Transceiver (VST) combines the flexibility of a software defined radio architecture and RF instrument class performance. You can use the VST to test a variety of cellular and wireless standards, and you can easily expand the VST's three-slot, 3U PXI Express form factor to support multiple input, multiple output (MIMO) configurations. The VST software is built on LabVIEW FPGA, and features several starting points for your application including application IP, reference designs, examples, and LabVIEW sample projects.

  • Multiple-Input Multiple-Output (MIMO) Sine Test

    Crystal instruments

    EDM Modal Sine Testing includes a dedicated test setup and operation process flow using a single or multiple modal shakers outputting a sine wave to acquire FRF signals. The Source Output type is either Swept sine or Stepped sine. The sweep mode can be linear or logarithmic. The FRF signals of each measurement DOFs with respect to defined reference DOF will be constructed. The output drive level can be defined to run the test under no control strategy, or the response of a control channel can be specified to run the test in a closed loop.

  • Optical Loss Test Set (OLTS)

    MaxTester 940/945 - EXFO Inc.

    First tablet-inspired, multifunction optical loss test set (OLTS) delivering insertion loss, optical return loss and fiber length measurements at two wavelengths in five seconds via fully automated bidirectional FasTesT™ analysis. With its step-by-step reference wizard and intelligent fault diagnosis, the MAX-940/945 provides expert guidance throughout the test process to ensure immediate efficiency by first-time users while removing risk of errors or negative loss—a common source of issues when testing low loss fibers.

  • Digitizer

    742 Family - CAEN S.p.A.

    The 742 is the Switched Capacitor Digitizer family, based on the DRS4 chip by PSI, with the highest sampling frequency (5GS/s) and channel density. It can record very fast signals from scintillators coupled to PMTs, Silicon Photomultipliers, APD, Diamond detectors and others, and save them with high efficiency and precision for advanced timing analysis. The 742 family has an additional channel (two channels in case of VME boards) which can be used as time reference for time of fight measurements. The resolution of this kind of measurements can reach up to 50 ps.

  • Synchro Power Amplifiers

    SSP - Computer Conversions Corporation

    The SSP Series are Compact, Reference Powered and Isolated Synchro Power Amplifiers, and AC Sine/Cosine ( Resolver ) to synchro converters; designed for moderate wattage, and re-transmission requirements; providing ultra high efficiency, and ultra high reliability in service, and ease of use. They are ideally suited for demanding Naval/Maritime, Aircraft, and Radar/Antenna related, applications. They are commonly used on synchro based data transmission, retransmission, simulation, and active control systems. They are suitable to drive both CT and CDX type passive loads, and virtually any synchro input instrumentation, or control.

  • Multi Channel Optical Fibre Verification

    LXinstruments GmbH

    The multi-channel optical fibre test system is used in the development and qualification of single mode optical fibres. The fibres are exposed to environmental influences in a climatic chamber in order to analyse the data on insertion loss and reflection. In addition, the current temperature in the climatic chamber is documented. Insertion loss measurement is performed with the help of an optical power meter, laser sources and optical switches. An Optical Time Domain Reflectometer (OTDR) from Exfo is used for the reflection measurements. The system was designed for the simultaneous characterization of 15 sample fibres and one reference fibre.

  • PXI Vector Network Analyzer

    NI

    PXI Vector Network Analyzers feature two ports, so you can choose between T/R test sets or full S-parameter capabilities. The PXI Vector Network Analyzer supports automatic precision calibration, full vector analysis, and reference plane extensions, so it is an ideal vector network analysis solution for your validation and production operations without the high cost and large footprint associated with a traditional benchtop VNA. These models seamlessly integrate into test systems for highly accurate, fast RF measurements.

  • 3D Software

    Geomagic Control X - Artec 3D

    Combined with the powerful and highly precise Artec 3D scanners, Geomagic Control X is a fantastic solution for anyone looking for speed, accuracy and a large variety of tools to choose from. Easily get the data required for extensive quality control in no time at all with Artec’s advanced 3D scanning solutions. Acquire precise measurements and carry out inspection and data analysis on the spot, using Geomagic Control X and an Artec 3D handheld scanner. Compare 3D scans to the reference CAD model to minimise assembly flaws and increase productivity.

  • Wire/Cable Harness Tester

    PANTHER 4HT - Qmax Test Technologies Pvt. Ltd.

    The Panther 4HT Wire \ Cable Harness tester is designed for Automotive and Semiconductor industry to apply in testing of wire harnesses, that needs testing during production with whole new fleet of features that make the task reliable, complete and fast. It uses innovative technology to test the impedance values. It can be interfaced to any type of fixtures as required. It uses the Learn and Compare technique for finding out opens or shorts in a harness. The learnt open / short combination from a Good Board is taken as reference and compared with the Board Under Test for any mismatch.

  • Optical Receiver Stress Test Solution

    N4917B - Keysight Technologies

    The N4917B software provides an automated standard compliant stressed receiver sensitivity test according to 100GBASE-LR4, ER4 and SR4 test specification. In order to do this kind of test, several test instruments such as a bit error ratio tester, digital sampling oscilloscope, optical reference transmitter and tunable laser source are required to operate together to achieve a compliant, repeatable optical stressed eye. This stressed eye is then fed to the receiver under test, where bit error ratio is measured under the stress conditions as defined in the standard.

  • PXIe-6672, TCXO PXI Synchronization Module

    780063-01 - NI

    PXIe, TCXO PXI Synchronization Module—The PXIe‑6672 is a system timing controller module. It can drive the PXI star trigger lines, import and export PXI backplane clocks and triggers, generate a high-resolution direct digital synthesis (DDS) clock, and generate a high-stability temperature-compensated crystal oscillator (TCXO) 10 MHz Reference Clock for instrumentation. The PXIe‑6672 allows you to synchronize multiple PXI Express systems, synchronize a PXI Express system with external instruments and equipment, and increase the accuracy of instruments within a PXI Express system.

  • PXIe-S5090, 9 GHz PXI Vector Network Analyzer

    787251-01 - NI

    PXIe, 9 GHz PXI Vector Network Analyzer - The PXIe-S5090 is a 2-port Vector Network Analyzer (VNA) that helps you measure amplitude, phase, and impedance. You also can use the PXIe-S5090 to perform time-domain analysis and to calculate the S-parameters of 2-port RF devices. It features a 300 kHz to 9 GHz frequency range, a wide dynamic range, and high sweep speeds for automated design validation and production test. Additionally, the PXIe-S5090 supports automatic precision calibration, full vector analysis, and reference plane extensions.

Get Help