  • Photolysis Rate Analyzer

    PFS-100 - Focused Photonics Inc.

    , HONO, HCHO etc.) are key indicators for identify status & extent of photochemical pollution.The analyzer is receiving solar radiation by quartz probe and transferring the radiation to spectrum via optical quartz fiber, the spectrum data will be evaluated and compared with reference data with mathematical approach and gives photolytic rate.

  • 1203c Broadband RF Distribution

    Precise Time and Frequency, Inc.

    The ptf 1203C Broadband RF Distribution amplifier provides high performance frequency references for laboratory or system use.The ptf 1203C uses two stages of input signal buffering to distribute the input signal to 12 separate outputs, and insure maximum isolation between individual output signals.

  • Radiating Comb Generators

    TBCG1 - TekBox Singapore Pte. Ltd.

    The TBCG1 is a radiating comb generator with an internal antenna and a base frequency of 100MHz. It radiates a comb spectrum characterized up to 6GHz. The comb generator is built and characterized to serve as a rough reference for testing radiated noise measurement set ups in anechoic chambers, TEM/GTEM cells, shielded chambers, etc.

  • Hydrogen Frequency & Time Standard

    CH1-1033 - VREMYA-CH JS Company

    The hydrogen frequency and time standard Ch1-1033 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes. Main areas of application: – public service of time and frequency; – ground control complexes of radio navigation systems; – radio interferometry with extra long base.

  • Bench Multimeters

    Fluke Calibration

    Fluke Calibration meters have the precision and versatility to handle the most demanding measurements, on the bench or in a system. These instruments are easy to use and offer excellent value that makes them an ideal solution for many applications. Standards laboratory meters include: Reference multimeters; precision digital multimeters; bench multimeters

  • Mezzanine System

    5174 - Abaco Systems Inc

    The 5174 provides two major functions, serving as a precision Voltage Controlled oscillator board and a variable frequency source board. These features can be use together or independently. As a variable frequency source, the 5174 provides a high-resolution variable clock source that is based upon a reference clock supplied by the ECM carrier.

  • Data Acquisition

    HEAD acoustics GmbH

    Sound, vibration, status and reference variables, voice, audio data and more: HEAD acoustics is setting the standard in data acquisition. We offer flexible systems for mobile applications and operation in the laboratory. Our data acquisition systems can also be expanded flexibly using various software and hardware modules.

  • Imaging Photometer & Colorimeter

    LumiTop 4000 / 2700 - Instrument Systems Optische Messtechnik GmbH

    The patented optical design permits simultaneous measurement of all three sensors in one shot. The accurate spectral measurement is used as a live reference and transferred to the complete display area of the camera. This makes for extremely short measurement times and all relevant optical tests are conducted in a single test station.

  • Gas Filter Correlation CO Analyzer

    Model T300 - Teledyne Advanced Pollution Instrumentation

    DescriptionFeaturesSpecificationsApplicationsDownloadsMaintenanceThe Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity.

  • Analog Tank Test Kit

    4108 - M. C. Miller Company

    The voltmeter included in the kit, the “Model IA” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers a 0 - 2VDC range with a 10MΩ input impedance and the analog display presents a color divided scale for convenient indication as to whether or not a carbon-steel structure is receiving a suitable level of cathodic protection, with respect to the accepted 0.85V (850mV) threshold value.

  • Active Type Hydrogen Frequency

    CH1-1003M - VREMYA-CH JS Company

    Hydrogen frequency and time standard Ch1-1003M is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes. Main applications: – national time and frequency services; – ground stations for tracking and control of satellite radio navigation systems; – radio interferometry with extra long base.

  • RF & Microwave Modules And Instruments

    SHF Communication Technologies AG

    In digital high speed test and measurement, a perfect clock signal is crucial for the generation of low jitter reference test signals. A SHF Synthesized Signal Generator (Synthesizer) used as a clock source can operate over several decades of frequency and is an essential part of any high speed test and measurement environment.

  • Current Sensing

    Texas Instruments

    voltage-output, current-sensing amplifier family that integrates an internal shunt resistor to enable high-accuracy current measurements at common-mode voltages that can vary from 0 V to 36 V, independent of the supply voltage. The device is a bidirectional, low- or high-side current-shunt monitor that allows an external reference to be used to measure current flowing in both directions through the internal current-sensing resistor sensor. The integration of the precision current-sensing resistor provides calibration equivalent measurement accuracy with ultra-low temperature drift performance and ensures an optimized Kelvin layout for the sensing resistor is always obtained.

  • FMC-HPC ADC Board

    FMC121 - Sundance Multiprocessor Technology Ltd.

    The FMC121 provides two 16-bit A/D channels up to 1Gsps and two 16-bit D/A channels up to 1.4 Gsps data rate with a 2.8 GSPS update rate. The design is based on Texas Instruments’ ADS54J60 Analog-to-Digital converter and Texas Instruments DAC39J84 Digital-to-Analog converter. The sample clock can be supplied externally through a coaxial connection or supplied by an internal clock source (optionally locked to an external reference) for multi-channel synchronization. An external trigger input is available for timing synchronization. The FMC121 is mechanically and electrically compliant to the FMC standard (ANSI/VITA 57.1).

  • ML/AI Low Power FPGA

    iCE40 UltraPlus - Lattice Semiconductor

    *Flexible logic architecture with 2800 or 5280 4 input LUTs, customizable I/O, up to 80 kbits of embedded dual port memory and 1 Mbit of embedded single port memory*Ultra-low power advanced process with static current as low as 75 uA and 1-10 mA active current for most applications*High performance signal processing using DSP blocks with multiply and accumulate functions*Soft Neural Network IPs and compiler for flexible Machine Learning/AI implementation*FPGA design tools, demos and reference designs to kick start designs