Emission
particles emanating from a source.
See Also: Acoustic Emission, Gas Emission, Radiated Emissions, Conducted Emission, Emission Reference Sources
-
product
Acoustic Emission Sensors
Acoustic wave (acoustic emission) sensors are the ceramic piezoelectric transducers converting the mechanical elastic acoustic waves generated in the material (e.g. elastic waves occur when a material cracks, wears, deforms, or corrodes) to electrical signals. The electrical signals are then amplified and filtered by a preamplifier and then transmitted to a special acoustic emission acquisition instrument for further data processing and analysis.
-
product
Online Emission Monitoring System
CEMS-4000 VOC
CEMS-4000 VOC is an online emission monitoring system based on catalytic oxidation-FID technology, which can monitor volatile organic compounds (including total hydrocarbons, non-methane total hydrocarbons, etc.) in the flue gas. The system supports multiple installation methods, including wall-mounted installation, platform installation, cabin-type installation, etc. It can be widely used in the oil and gas industry, electronics industry, automobile manufacturing industry, and pharmaceuticals industry.
-
product
Optical Emission Spectrometers
Optical emission spectrometers (OES) and the measuring principle of the atomic emission are the ideal method and provide the perfect instrumentation for metal analysis in all different industrial businesses and environments.
-
product
Optical Emission Spectrometer
PDA-8000
This instrument is capable of high sensitivity quantitative analysis of iron and steel, copper, aluminum alloys and other solid metals, as well as impurities and other elements, thanks to a high resolution monochromator and discharge energy stabilized excitation unit. Excellent operability is achieved with software that enhances instrument monitoring and maintenance support functionality. In addition, this is an energy saving model that significantly reduces energy consumption.
-
product
Acoustic Emission Crack Diagnosis
Detect abnormality by diagnosing machine condition in real time
-
product
Optical Emission Spectrometers
Optical emission spectrometers (OES) and the measuring principle of the atomic emission are the ideal method and provide the perfect instrumentation for metal analysis in all different industrial businesses and environments.
-
product
Acoustic Emission Transducer
ZET 601
The acoustic emission sensor is the most important element of any acoustic emission NDC system. The ZET 601 acoustic emission transducer converts AE-process acoustic signal to an electric signal parameters of which are used for the assessment of acoustic emission sources.They are used for technical diagnostics using passive ultrasound.
-
product
Stack Emission
Gases released into the air from boiler stack, chimneys or DG set stack etc. from various industries after incineration process.
-
product
Optical Emission Spectrometer
PDA-7000
Emission spectrometry provides rapid and accurate simultaneous determination of many elements in metals. This technique has been adopted as standard method for metal analysis. The Shimadzu PDA-7000 is high performance optical emission spectrometers, utilizing the PDA method as standard, which enhances the accuracy and reliability of analysis. The PDA method, combined with excellent hardware quality, make the PDA-7000 suitable for any application in metal analysis. They enhance analysis productivity in quality control and process control in the ferrous and non-ferrous metal industries.
-
product
Continuous Emission Monitoring Data Acquisition System
CEM-DAS
CEM-DAS is a complete networkable system for continuous recording and evaluation of emission data in all industries. The system provides important information for the environmental and economic operation of production facilities. CEM-DAS is scalable to support smallest one stack installations up to multi-block plants with numerous measuring points. CEM-DAS has proven its robustness in a German TÜV test which requires 99 % uptime.
-
product
Plasma Emission Detectors for Gas Chromatographs
Our patented Plasma Emission Detector is available for integration into any gas chromatography system or installation. It has been designed for ‘plug and play’ installation and to allow for analysis of impurities from PPB to % levels using either capillary or packed columns.
-
product
Emission Monitoring Systems
Gasmet’s emission monitoring systems set the standard for accurate, reliable, and cost-effective gas analysis. Our state-of-the-art solutions are designed to provide precise measurements of gaseous emissions, making compliance with environmental regulations seamless. With a focus on continuous emission monitoring systems (CEMS), we deliver innovative technology that balances sensitivity, durability, and affordability. Our products are fully TÜV and MCERTS-certified, ensuring world-class quality and performance. Trusted globally, our emission monitoring solutions are the future of gas analysis, empowering industries to meet stricter environmental requirements effortlessly.
-
product
Inductively Coupled Plasma Emission Spectroscopy
Inductively Coupled Plasma Emission Spectroscopy
-
product
Acoustic Emission Instrument
VPAC™II
The VPAC™II is an acoustic emission instrument based on over 10 years of research. The VPAC™II can estimate the quantity of material leaking through the valve using the accompanying proprietary software. With hundreds of systems currently in use, the VPAC™II valve leak detector is the instrument of choice for through valve leak detection.
-
product
Emission software
EMiScan
This Windows Emission package is an ideal debug / development tool providing easy of use with a flexible approach so you can quickly capture and manipulate data
-
product
Sound Level Meter for Automotive – Car Noise Emission Inspection
HD2010MCTC
The level of noise produced by vehicles shall comply with standards prescribed by international regulations. During car inspections, horns and exhaust devices must be in good condition and comply with the requirements.
-
product
Emission Testers
Maschinenbau Haldenwang GmbH & Co. KG.
A device that monitors the composition of the flue gas of a boiler heating unit to determine if the mixture of air and fuel is at the proper ratio for maximum heat output.
-
product
RFI Power Emission
AFJ receivers and accessories for the disturbance power using the absorbing clamp measurement, are conforming to CISPR 16-1-1 and CISPR 14-1.
-
product
EMI EMC test Solutions for Emission
Scientific Mes-Technik Private Ltd
EMI EMC test Solutions for Emission
-
product
Acoustic Emission Transducer
GT200
Acoustic emission transducer is a key element of non-destructive acoustic emission testing. Transducers GT 200 are used for technical diagnostics by means of passive ultrasound.
-
product
Acoustic Emission (AE) Monitoring System
Sensor Highway II System
The Sensor Highway II System™ is an Acoustic Emission (AE) monitoring system with up to 16 high-speed channels and 16 standard parametric input channels (expandable to over 100). The system is designed for unattended and remote monitoring use in Structural Health Monitoring management and condition monitoring applications. It is rated for outdoor use and comes equipped in a rugged weather proof NEMA 4 enclosure.
-
product
Portable Emission Analyzers
Portable Emission Analyzers are especially useful for, auto repairs, inspections, safety checks, and general engine tuning. Simply insert a probe into the exhaust pipe and press a key to initiate measurements. Readings appear on a back-lit liquid-crystal display on the front of the analyzer.
-
product
Zero Emission Cabinets
A zero emission cabinet is connected to the exhaust extration system of the building and prevents exhaust gases from escaping into the building.VLT offers several different zero-emission cabinets for use with emission and diesel smoke analysers. They can be connected to your exhaust extraction system. Mandatory in some countries.
-
product
CDNE For Emission Measurement On Luminaries
CDNs have been used as coupling-/decoupling networks to measureconducted noise as well as for immunity testing so far.
-
product
RSE Wireless EMC Spurious Emission
TS8996
The R&S®TS8996 RSE test system is designed for EMI and radiated spurious emission testing on wireless devices in semi-anechoic or fully anechoic chambers. The modular design makes it easy to extend the system to include new communications technologies. Typical devices under test include mobile phones or radio sets along with radiated measurements of other short-range devices. Standards require a wide range of test setups and a wide and high frequency range (up to 40 GHz). ESW or FSW frequency ranges are extended up to 325 GHz with option B21 using receive units TC-RSE for 5G FR2. Dedicated RSE test routines are also covered for this frequency range.
-
product
Acoustic Emission Instruments
The Acoustic Emission NDT technique is based on the detection and conversion of high frequency elastic waves into electrical signals.
-
product
CEMS II E Continuous Emission Monitoring System
CEMS II e takes away the manual configuration and settings adjustments from your day-to-day emissions measurements. A fully automated continuous emission monitoring system CEMS II e is TÜV and MCERTS certified solution (QAL1) to offer environmental compliance. This emission monitoring system is suitable for measuring pollutants continuously from hot, wet and corrosive gas streams in various industrial processes, such as powerplants, waste incineration, cement plants and beyond.
-
product
Principle Of Optical Emission Spectrometry
Optical emission spectrometry involves applying electrical energy in the form of spark generated between an electrode and a metal sample, whereby the vaporized atoms are brought to a high energy state within a so-called "discharge plasma".
-
product
Endpoint / Chamber Health Monitor based on Optical Emission Spectroscopy and MWL Interferometry
EV 2.0 Series
To address new requirements in Semiconductor, lighting devices, automotive components, flat panels, MEMS sensors, memory chips, and logic electronics processed in the industry using dry etch, cleaning and (PE)CVD, HORIBA has introduced a unique generation of sensor dedicated to Advanced Endpoint Control, Fault Detection and Chamber Health Monitoring.





























