Filter Results By:

Products

Applications

Manufacturers

IEC

International Electrotechnical Commission.

See Also: Standards, IEEE


Showing results: 526 - 540 of 585 items found.

  • Low TCR High Power Current Sensing Resistors, Wide Terminal Type

    Panasonic Industrial Devices Sales Company of America

    Panasonic's ERJ-D1 and ERJ-D2 Series, Low TCR High Power Current Sensing Chip Resistors, achieve high power and low TCR (±100×10–6/°C) using a wide terminal electrode structure and original materials.These Resistors are suitable for small size/high power current detection and their low TCR enables high accuracy of current detection. The ERJ-D1 Series features higher rated power at 2W in a 1020 case size while the ERJ-D2 Series features 1W in a 0612 case size. These Resistors are AEC-Q200 Compliant and offer IEC 60115-8, JIS C 5201-8 and EIAJ RC-2134B Reference Standards ensuring optimal quality and reliability.

  • Universal Spring Impact Hammer 0.14J To 1.0J

    Shenzhen Chuangxin Instruments Co., Ltd.

    The Universal Impact Hammer is designed to perform impact tests for product durability. The CX-T03 meets the testing needs of industry standards such as IEC 60065, 60335, 60598, 60601, 61010 and others. The hammer simulates mechanical impact to electronic products and electrical appliances. This impact hammer is versatile -- it can be dialed to a whole range of energy values to perform tests to many different standards. A compressed spring accelerates a hammer head to hit the sample undergoing test. The spring is released from a lock mechanism by pressing the cone-shaped top of the impact hammer against the product under test. The CX-T03 is adjustable from 0.2 Nm to 1 Nm by turning a ring on the hammer.

  • Relaying Current Transformer Analyser

    Eltel Industries

    *Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.

  • Transformer Variable Radio Tester

    WABC - Wuhan Sangao Electrical Test Installations Limit Co.

    Acc to IEC and Relevant national standard, In the power transformer production, transfer and user test process, Transformer ratio test is necessary project, This can be used for quality supervision of transformer factory and the use process, prevent the transformer winding inter turn short circuit, open circuit, connection error, pressure regulating switch failure or contact fault.So our company development and production of automatic ratio tester in the original basis according to the user's site using requirements , make the operation more convenient, complete function, stable and reliable data, the testing speed is greatly improved.To meet the needs of all kinds of small medium and large transformer ratio test.

  • HMM+™ Tester

    Model 4702 - Barth Electronics, Inc

    The Model 4702 HMM+™ is a completely new tester primarily intended for device level testing and produces a current waveform as specified in the IEC-61000-4-2, from a 50 ohm source impedance system.*This tester provides device level test data that allows users to evaluate the IEC current waveform protection level of their devices. We included failure identification by leakage current increases in the 4702 tester so precise pass/failure levels can be closely measured.*The 4702 HMM+™ provides a new and improved test connection method for making quantifiable and repeatable device level HMM measurements.*Convenient, precise, repeatable operation*Computer controlled for automated testing

  • Automated AC Digital Hipot Tester

    Educated Design & Development, Inc.

    1 button testing - No setup required, just plug right in! Or, make a plug for your cordless product, and plug right in! EASY!Easy to identify PASS / FAIL visible and audible indicationAuto Test Time (1 sec. / 60 sec.)+ - No need to set a timer or clock watchSafety Protected Start Switch -- Protects user from shock!Performs the Low Current Ground Continuity test at the same timeMeets UL, CSA, CE, EN, IEC, MIL and all other international safety agency requirements as well as UL 120Kohm requirementsIncludes ISO/IEC 17025 Accredited Calibration Certificate, accredited by ACLASS (Internationally accepted results... equivalent to A2LA)

  • Digital Panel Meter

    ST-312V (ST-312mV) - Standard Electric Works Co., Ltd

    ● 3 1/2 digit liquid crystal display.● 200mV and 2V full scale input sensitivity.● Single Battery operated 9V supply or ±5V DC power supply (Dual supply).● Built-in low battery indication and automatic polarity indication.● Decimal point selectable.● Low power dissipation Typically less than 20mV.● High input impedance (> 1M ohm).● Guaranteed zero reading for 0 volts input on all scales.● True differential input or single-ended input.● Self mountable with optional mounting bezel.● Low cost high performance.● EN 50081-1 EN 50082-1 EN 55022 EN 61000-4-2 IEC 801-3

  • Digital Panel Meter

    ST-312A(4~20mA) - Standard Electric Works Co., Ltd

    ● 3 1/2 digit liquid crystal display.● 200mV and 2V full scale input sensitivity.● Single Battery operated 9V supply or ±5V DC power supply (Dual supply).● Built-in low battery indication and automatic polarity indication.● Decimal point selectable.● Low power dissipation Typically less than 20mV.● High input impedance (> 1M ohm).● Guaranteed zero reading for 0 volts input on all scales.● True differential input or single-ended input.● Self mountable with optional mounting bezel.● Low cost high performance.● EN 50081-1 EN 50082-1 EN 55022 EN 61000-4-2 IEC 801-3

  • Leakage Current Tester

    TOS3200 - Kikusui Electronics Corp.

    The Leakage Current Tester TOS3200 is designed to perform leakage current (touch current and protective conductor current) tests on general electrical equipment but not medical electrical equipment.It enables you to conduct tests that conform to the requirements of the applicable IEC, UL, JIS, and other standards, as well as the Electrical Appliance and Material Safety Law. The memory in the main unit stores the 51 types of test conditions laid down in the IEC/JIS standards for information technology equipment, household electrical appliances, audio, video electronic apparatus, luminaires, motor-operated electric tools, and electrical equipment for measurement and control and in the Electrical Appliance and Material Safety Law, thereby enabling you to conduct standard tests with simple panel operation.

  • Sound Level Meter/Datalogger

    Extech SDL600 - Extech Instruments Corporation

    The SDL600 records data on an SD card in Excel format. High accuracy ±1.4dB meets ANSI and IEC 61672-1 Type 2 standards. 30 to 130dB measurement range. Auto or Manual ranging. AC analog output for connection to an analyzer or recorder. Large backlit LCD display. Stores 99 readings manually and 20M readings via 2G SD card. Datalogger date/time stamps and stores readings on an SD card in Excel format for easy transfer to a PC. User programmable sampling rate from 1 to 3600 seconds. Featuring Min/Max, Data Hold, and Auto Power Off functions. Complete with 6 AA batteries, SD Card, wind screen, and hard carrying case.

  • [5kV AC] Hipot Tester, Rise/Fall-Time Control Function Equipped

    TOS5200 - Kikusui Electronics Corp.

    TOS5200 is designed for AC Hipot Test with 500 VA capacity and 200 mA short circuit current output capability. Equipped with the PWM amplifier, the TOS5200 can provide a stable & reliable output without being affected by ACpower line. Therefore, it is a perfect solution for electronic equipment or devices complied to IEC, EN, UL, VDE andJIS etc. requirement.As TOS5200 covers most of features of our upper class model for AC Hipot Test, it achieves thesuperb cost / performance ratio for those who need 200 VA or 500 VA capacity, or both. Also, as it equips the Interlockfunction together with other safety features, operator can carry out the test with higher current value in safe.

  • Wall-Mount Miniaturized 24V OEM Version of Rapidox 2100

    Rapidox 2100-OEM-RSB-WALL - Cambridge Sensotec Ltd

    The Rapidox 2100 OEM-RSB-WALL is a wall mount version of our miniaturised 24V OEM oxygen (O2) analyser. The compact (4.5″ x 3.0″) circuit is integrated into a neat IP65 wall mount polycarbonate box, with a clear smoked hinged lid. Behind this is a clear OLED display and menu keypad. The box is completely electrically isolated and meets all UL and IEC standards for these types of enclosures. There are cable entry glands on the base for power cables and analogue / digital / alarm leads The analyser comes with a robust cabled zirconia sensor, which is ideal for providing fast and accurate remote in-situ gas analysis over the the full oxygen range 10-20ppm to 30% O2. An optional external pressure sensor socket is included as standard.

  • LVDS (Low Voltage Differential Signaling) Drivers and Receivers

    Analog Devices Inc.

    LVDS (Low Voltage Differential Signaling) Drivers and Receivers from Analog Devices offers designers robust, high speed signaling for single-ended to differential solutions for point-to-point applications. Our selection of products conform to the TIA/EIA-644 LVDS standard and contain the first LVDS transceivers to meet 8 kV IEC ESD performance standards - important for robust, interboard applications where the connectors can be exposed to more harsh electrostatic environments. Companion differential line receivers and differential line drivers support up to 600Mbps. LVDS greatly improves noise immunity and minimizes emissions for high speed point-to-point data transmission and is a low power alternative to emitter-coupled logic (ECL) or positive emitter-coupled logic (PECL) signaling.

  • New Car Battery Tester

    Hangzhou Xun Anda Electrical Co., Ltd.

    1. Test application: 12V/6V batteries test and 12V Starting /Charging system test.2. Test battery type: regular liquid, AGM battery, GEL battery.3. CCA test range: 40~2000CCA (SAE).4. Voltage test range: 1.5-15V.5. Display SOH (state of health), SOC(state of charge).6. Test for multiple battery standards: SAE, DIN, EN, IEC, CA.7. Graphic LCD display with back light, LCD brightness adjustable.8. Multigle language operation: English, Chinese, Germany, French, Spanish.9. Intergrated thermal printer to print test reports.10. Thermal printer paper roll is 58mm width and 7.5m long.

  • New VRLA Battery Tester

    Hangzhou Xun Anda Electrical Co., Ltd.

    1. Test application: 12V/6V batteries test and 12V Starting /Charging system test.2. Test battery type: regular liquid, AGM battery, GEL battery.3. CCA test range: 40~2000CCA (SAE).4. Voltage test range: 1.5-15V.5. Display SOH (state of health), SOC(state of charge).6. Test for multiple battery standards: SAE, DIN, EN, IEC, CA.7. Graphic LCD display with back light, LCD brightness adjustable.8. Multigle language operation: English, Chinese, Germany, French, Spanish.9. Intergrated thermal printer to print test reports.10. Thermal printer paper roll is 58mm width and 7.5m long.

Get Help