Showing results: 151 - 165 of 367 items found.
-
IS-*MA**P/IS-*MA**C -
Lisun Electronics Inc.
According to IES LM-79 Clause 9.1.2, it request the 4π geometry configuration and 2π geometry Integrating Sphere for the LED Testing. Lisun Group developed the integrating sphere with side assistant Opening in A Molding Technology to meet the requirements.• Painting material of integrating spheres is according to CIE Pub.No.84 (1989) • The painting material is BaSO4 coating: ρ (λ) ≥0.96 (450nm~800nm) and ρ (λ) ≥0.92 (380nm~450nm) • Fine diffuse reflection: Reflectance ρ≈0.8 and accuracy of ρ (λ) <1.5% • Build-in all functional lamp testing jigs: the vertical is for E40/E27, the horizontal is for T5/T8/T12 tubes and the Testing Holder Base for LED street luminiares. All of the testing jigs can allow the lamp be tested up and down in the sphere. • Power Cable, Power Terminal and Auxiliary lamp position has been built-in (Auxiliary lamp is option). • Two photo detector ports, one optical fiber port and temperature sensor hole are built-in • Ordering Code: IS-1.5MA55P or IS-1.5MA55C (Φ1.5m, IS-1.5MA55P means square side opening is 0.5×0.5m, IS-1.5MA55C means cycle side opening diameter is 0.5m). IS-1.75MA66P or IS-1.75M66C (Φ1.75m and side opening is 0.6m). IS-2.0MA77P or IS-2.0MA77C (Φ2.0m and side opening is 0.7m). • Other size such as diameter 2.5m, 3.0m can be special order according to customer’s request
-
WT4000 -
Lisun Electronics Inc.
• Measure parameter: 1) Input: Vrms, Lrms, W, PF, Hz, Phasic angle, total harmonic and 0-39 component of harmonic. 2) Output: Lamp voltage, Lamp current, Filament current, Guided cathodic current, Lamp power, crest factor and oscillatory frequency, single high frequency analysis. • Startup: Startup lamp voltage, lamp current, filament current, guided cathodic current curve and parameter, preheating time; • Simultaneously display on 8 windows for input and output parameters, convenient for comparison and analysis; • Test preheat energy, filament preheat time. And the parameters changes from 0 to 5s of filament voltage, filament current and filament power; • Up to 1MHz lrms test content to every EB; • Analysis symmetry of high Frequency curve of lout; • 12-bit high-speed A/D, sampling rate up to 10MHz, can easily analyse signal curve of output; • Finish an input and output testing at the same time within 1 minute; • Portable, can test, display, print without computer. Test report include data and curve, comply with international standard; • Communication port for PC, run under Windows98 or Windows2000, English Version available.
-
CHROMA-2 -
Lisun Electronics Inc.
CHROMA-2 Pocket Chroma Meter is developed based on TOSHIBA TCD1304DG linear array CCD detector. It makes traditional laboratory instrument available for the production on-line quality acceptance, thus greatly improved the efficiency of fluorescent lamp, CFL, LED.
-
Series 800 -
Aries
Vertisockets Horizontal Mounting with Bifurcated Contacts. Aries offers a full line of VertisocketsTM for DIP packaging of LEDs, incandescent lamps, DIP switches, test points, etc. The variations of mounting position and pin configuration provide exceptional design freedom.
-
Part No. S422 -
Teledyne Defense Electronics Relays & Coax Switch
TO-5 hermetically sealed package, SMT-J mounted, magnetic-latching DPDTAvailable options include:S422D - coil transient suppression diodeS422DD - polarity protection diodeResistive: 1 Amp/28Vdc Inductive: 200 mA/28Vdc (320 mH) Lamp: 100 mA/28Vdc
-
Part No.s 412V, 412DV -
Teledyne Defense Electronics Relays & Coax Switch
TO-5 package, through-hole mounted, DPDT high-vibration relayAvailable options include:412V - high-vibration, non-latching412DV - high-vibration, non-latching, with coil transient suppression diode Resistive: 1 Amp/28Vdc Inductive: 200 mA/28Vdc (320 mH) Lamp: 100 mA/28Vdc
-
Part No. 255, J255 -
Teledyne Defense Electronics Relays & Coax Switch
1/2 Size Crystal Can hermetically sealed package, through-hole mounted,magnetic -latching DPDTAvailable options include:J255 - Qualified to MIL-PRF39016/45 Resistive: 2 Amp/28Vdc Inductive: 750 mA/28Vdc (320 mH) Lamp: 160 mA/28Vdc
-
Part No. HR422, HRS422 -
Teledyne Defense Electronics Relays & Coax Switch
TO-5 package, through-hole or SMT mounted, latching DPDT, DC-1GHzAvailable options include:HR422 Latching, through-hole mounted, DPDTHRS422 Latching, SMT J-lead mounted, DPDTResistive: 1 Amp/28Vdc Inductive: 200 mA/28Vdc (320 mH) Lamp: 100 mA/28Vdc
-
ABET Technologies Inc.
Standard maintenance, lamp, or filter replacement, does not require any tools. Locking indicator dials on all the system controls, located together for ease of alignment, provide for a reproducible setup. A beam imaging accessory makes alignment even faster.
-
Alpha-Omega Power Technologies, LLC.
Alpha-Omega Power Technologies (AOPT) has developed a line of pulsed concentrator photovoltaic (CPV) solar simulators based in its experience with pulsed high voltage flash lamp systems and its patented high speed, high power load.
-
CPS+ -
Atlas Material Testing Technology
The practical benchtop xenon lamp unit with useful accessories to tailor your SUNTEST towards your needs. Here you see the SunCool chiller (for pharmaceuticals / cosmetics), the SunTray sample exchanger (for in-vitro SPF), and the SunFlood immersion unit ( for coatings / sealants).
-
Part No.s 412H, 422H, 432H -
Teledyne Defense Electronics Relays & Coax Switch
TO-5 package, through-hole mounted, DPDT high-temperature relayAvailable options include:412H - high-temperature, non-latching422H - high-temperature, magnetic-latching 432H - high-temperature, non-latching, low-power coil Resistive: 1 Amp/28Vdc Inductive: 200 mA/28Vdc (320 mH) Lamp: 100 mA/28Vdc
-
Mini-CrimeScope Advance -
HORIBA, Ltd.
The Mini-CrimeScope Advance builds on the knowledge and expertise of more than 20 years of Forensic Light Source design. It incorporates the same ease of use and unmatched reliability of its predecessor, along with the latest in arc lamp technology. The result – a unit that is unsurpassed in performance.
-
CX-HP2 -
Shenzhen Chuangxin Instruments Co., Ltd.
Light source colorimeter is a newly developed pocket colorimeter, adopting advanced spectrometer and microprocessor technology. It makes traditional laboratory instrument available for the production on-line quality acceptance, thus greatly improve the efficiency of fluorescent lamp, CFL, LED manufacturing.
-
FC-2 -
Shenzhen Chuangxin Instruments Co., Ltd.
This Flushing Test device is designed according to terms and conditions of IEC60529,GB4208-2008,GB7000.1-2007,GB4706.1-2005,etc. Accordance with requirements of IPX5/6.Applied to carry out waterprooftest on LED lamps, house hold appliances, electric and electronic products and other electric accessories.