Ionizers
Neutralize static charge.
-
Product
Thin-Type Ionizers
ER-VW Series
-
Panasonic Industrial Devices Sales Company of America
The Panasonic ER-VW Thin-Type Ionizer uses high frequency AC in an ultra-thin Ionizer for superior static elimination.
-
Product
Compact Fan Type Ionizers
ER-Q Series
-
Panasonic Industrial Devices Sales Company of America
With Panasonic’s high-frequency AC method and “Sirocco Fan”, the ER-Q Compact Fan Type Ionizer can remove electrostatic charge even at slow fan speeds.ER-Q Ionizers are extremely compact and well suited for removing localized electrostatic charge on manufacturing equipment for electronics or in Semiconductor processes. The ER-Q Ionizers require no compressed air which eliminates air lines and reduces additional maintenance.
-
Product
Pulse Air-Gun Ionizers
EC-G Series
-
Panasonic Industrial Devices Sales Company of America
With the new Pulse Air-Gun Ionizer from Panasonic, operators can comfortably neutralize static electricity while manually cleaning. The Pulse Air-Gun’s light-weight, ergonomic design combined with an oil and heat-resistant 2m cable makes it ideal for use at the production line.The Air-Gun Ionizer is equipped with a white LED on the front of the Gun to illuminate target objects. It has three air emission modes: long pulse, short pulse and continuous emission. Ionized air can be emitted at high pressure (range 0.05 to 0.50 MPa), neutralizing static charges and removing dust simultaneously and swiftly.
-
Product
GFID Analyzer
-
Gasmet Flame Ionization Detector (GFID) is designed for continuous total hydrocarbon (THC) measurements. GFID analyzer offers a TÜV certified solution (QAL1) for measuring pollutants from hot, wet and corrosive gas streams.
-
Product
Static Control Devices
-
Panasonic Industrial Devices Sales Company of America
There are many production processes where electrostatic charges disturb smooth operation. To eliminate static, Ionizers are used.Whether the application is for the Semiconductor industry where the components are extremely sensitive and can even be damaged by high electric static charges or for the packaging industry, where plastic sleeves or foils tend to stick to each other, Panasonic has a solution to neutralize electrostatic charge.
-
Product
Static Remover (Ionizer)
STABLO-AP
-
STABLO-AP provides reliable measurement by removing static electricity.
-
Product
Ionizers
ESD
-
Electrostatic discharge (ESD) is the release of static electricity when two objects come static control ESD IT-7000 Tabtop ionizerinto contact. Familiar examples of ESD include the shock we receive when we walk across a carpet and touch a metal door knob and the static electricity we feel after drying clothes in a clothes dryer. A more extreme example of ESD is a lightening bolt. While most ESD events are harmless, it can be an expensive problem in many industrial environments.
-
Product
High Mount Ionization Transport System
HM-8000
-
The Model HM-8000 High Mount is designed to be suspended over the work station with the ionized air blowing down over the area to be protected against an ESD event which is caused by static electricity build up.
-
Product
Tabletop Ionizing Transport System
90610-03610
-
The Model IT-7000 Ion Transport System is a self contained, compact table top ionizer capable of producing copious amounts of both positive and negative ions. The variable speed fan permits a gentle flow of ionized air, reaching a distance of up to 4 feet. A charged object, when passed through the ionization field, becomes neutral instantaneously. Inherently balanced, the Ion Transport System has a fail safe balance indicator to assure proper ionization output for ESD static control applications.
-
Product
Fan Type Ionizer
ER-F
-
Panasonic Industrial Devices Sales Company of America
With a compact size of 150 x 166 x 62mm and a fan of 120mm in diameter, the ER-F Fan Type Ionizer belongs to the leading class of compact Fan Type Ionizers. The system employs a high-frequency AC method and boasts a +/-2kV discharge output voltage that discharges electrostatic contaminated objects quickly and safely. Louvers for long distance and wide area applications are shipped with the Ionizers. Standard fan types for faster charge removal times and low-volume types for discharging small parts or film are available.
-
Product
Professional Floor Certification Kit
PFC-252
-
The PFC-252 includes Prostat's PRS-812 Resistance System Set with modified 5 pound conductive rubber electrodes and Prostat’s Cable Spacers for exact measurements. The PRS-812 wide range resistance system can take measurements at 10 and 100 volts with accuracy within ±5%. Also included is the PFK-100 Field Meter Set. The PFK-100 set includes Prostat's unique PFM-711A dual range field meter, CPM-720A charged plate monitor assembly and PCS-730 ±1 kv charging source. With this instrument set you can measure electrostatic fields, analyze ionizer performance and assess the voltage generation of materials, equipment and personnel.
-
Product
Radius Radiation Probe
Hawk Radius®
-
The Hawk® Radius is a ruggedized solution for monitoring both ambient and elevated levels of ionizing radiation. Like a Hawk with its remarkable vision, the Hawk Radius Probe “sees” things that other probes cannot. The high sensitivity weatherized pancake sensor can provide early warning of changing ambient radiation conditions, while the energy compensated detector can accurately report penetrating gamma radiation dose rate at elevated levels. Radius probes are typically deployed as part of an environmental radiation monitoring program, or for safety and security systems. In its standard configuration the probe detects beta, low energy gamma and x-radiation with one channel and energy compensated penetrating gamma radiation levels with a second channel. It can be configured to detect alpha radiation as well. The Hawk® Radius has been deployed worldwide in demanding conditions for protecting communities and collecting environmental radiation data. It can be deployed easily and requires minimum maintenance. The Radius is compatible with Medcomʻs GeigerLink adapter and the IMI Gateway App for use with personal computers. It can also be used with most data loggers including popular Campbell Scientific models.
-
Product
Gamma Detectors
-
In Gamma detectors, the gamma radiations produce electrons by interacting with the cathode material and the filling gas.These electrons ionize the gas and the charge carriers are collected by the electrodes. The resulting anode pulse is detected by a load circuit. The primary electrons are created by several interaction mechanisms:- Photoelectric effect- Compton scattering- Pair production
-
Product
Ionizers / Active Oxygen Module (Ozonizers)
-
Ionizer and ozonizer modules utilize high voltages to ionize/ozonize air molecules. They enable air purification, bacteria removal, deodorization, static charge elimination, electrostatic charging and more, and are widely used in air conditioners, air purifiers, refrigerators, washing machines and other products.
-
Product
Static Field Meters and Ionization Test Kits
-
Portable Meter for Testing of Electrostatic FieldsMeasures surface voltage and polarity on objects up to 19.99 kV at a distance of 1 inch.Durable Dissipative Housing Design with Membrane Switches (NEW)Protects meter from physical damage and minimizes wear.LED Range FinderRed ranging lights help
-
Product
PRODUCTS TESTING
ESD
-
MicroStat Laboratories -R.E.T.S.
Our ESD test capabilities include resistance, resistivity, electrostatic shielding, charge generation, and charge dissipation. We routinely test flooring materials, packaging, footwear, garments, ionizers and many other ESD control products and materials. We utilize the relevant test methods and standards of the ESD Association, ANSI, ASTM, NFPA, IEST, IEC, AATCC, or our clients’ in-house specifications.
-
Product
Flame Ionization Detector
-
A flame ionization detector converts a hydrocarbon gas concentration into an electrical signal. The flame is hydrogen fueled and burns in hydrocarbon free combustion air. Either side of the flame are two electrodes between which an electric field is generated by means of a polarization voltage. The sample is pre-mixed with the fuel gas and heated in the flame to a temperature at which the hydrocarbon molecules ‘crack’ and CH fragments appear. These CH fragments are oxidated by the oxygen in the combustion air resulting in the formation of CHO+ ions. The ion current then passes to the electrodes and the resulting current measured is proportional to the quantity of C atoms derived from organic compounds.The Thermo-FID features two separate microprocessor controlled pressure compensations to avoid any influence from environmental or sample conditions. In addition, the complete Thermo-FID range of analyzers are equipped with a flame trap that is used as a heated sample inlet filter. The measurement chamber and all material in contact with the sample gas are heated between 120°C and 200°C to avoid condensation.
-
Product
GC/MS CI , CI/NCI And SMCI Measurement
-
CI is a softer ionization method than EI, fragmentation is less likely to occur, so molecular weight information is more readily obtained. Negative chemical ionization (NCI) or negative ion chemical ionization (NICI) enables selectively measuring, with ultra high sensitivity, chemical substances with an electron affinity, such as chlorine-based compounds.
-
Product
Ionization Anti Static Blower
-
Ionization or anti static blowers are the most versatile ionizer to control or remove static electricity from plastic, paper, glass and other non conductive materials. This static control blower offers the ability to cover a large area cost effectively. This static control equipment is an excellent choice to reduce static electricity and reduce operator static shocks and production applications needing large area coverage.
-
Product
HDC-AC Equipped
-
The ionizer equipped with a new high-voltage power supply (HDC-AC) was developed independently by Shishido Electrostatic (patented). It is a groundbreaking product that combines high-level static elimination performance with long-term stability. Compared to general ionizers, it has excellent characteristics, such as the ability to maintain static elimination performance for a long period of time without the need for short-term cleaning or part replacement.
-
Product
Other Environmental Testers
-
GAOTek’s environmental testers can be used to measure parameters such as humidity, temperature, wind speed or velocity, wind direction, air quality, electromagnetic waves, ionizing radiation and more. Environmental testers are applicable in climate monitoring to occupational health and safety (OHS) applications. Our environmental testers are useful tools for collecting data about the immediate surroundings. Depending on the model, an environmental tester can function as a data logger for long-term data by collecting and storing measurement data over a certain period. Our environmental test solutions are affordable and dependable and are perfect for general to specialized jobs.
-
Product
Charge Plate Monitors
-
Our easy-to-use charge plate monitors allow you to accurately evaluate air ionization systems used to neutralize static charge accumulation. Benefit from our economical solutions and products that offer onboard data storage to automate ionization system testing.
-
Product
Radiation And Process Monitoring Systems
ProTK
-
Monitoring of the main steam line for leakages in a PWR nuclear power plant with a wide-range gamma ionization chamber.
-
Product
Charged Plate Monitor
Model 280A
-
Simco-Ion’s Model 280A incorporates enhanced circuitry that enables it to more accurately measure the performance of high frequency AC ionizers, as well as pulsed DC ionizers and steady-state DC ionizers. The Model 280A can be used as a portable CPM and is capable for of up to 6 hours of operation on the internal battery before recharge.
-
Product
Cryogenic Temperature Sensors
Cernox®
-
Cernox® thin film resistance cryogenic temperature sensors offer significant advantages over comparable bulk or thick film resistance sensors. The smaller package size of these thin film sensors makes them useful in a broader range of experimental mounting schemes, and they are also available in chip form. They are easily mounted in packages designed for excellent heat transfer, yielding a characteristic thermal response time much faster than possible, with bulk devices requiring strain-free mounting. Additionally, Cernox sensors have been proven very stable over repeated thermal cycling and under extended exposure to ionizing radiation.
-
Product
Radiation Meters
-
A radiation meters is a device designed for measuring varying types of radiation. These devices are portable and are used to inspect personnel, equipment, and facilities for radioactive contamination by measuring the emission of certain radiation particles. They are used to measure external or ambient ionizing radiation field to assess the direct exposure hazard.
-
Product
Radiation Survey Meter For First Responders
Radalert 200™
-
The Radalert 200 is a rugged solution for monitoring both ambient and elevated levels of ionizing radiation in challenging environments. Simplified user interface requires minimal training. Detects and measures alpha, beta, gamma, and X-radiation. Data is displayed in your choice of counts per minute (CPM), μSv/hr or mR/hr, or in accumulated counts. A red LED blinks and a beeper chirps with each count (can be muted). An audible alert sounds when the radiation reaches a user adjustable level.
-
Product
Deep Ultraviolet Spectrophotometer System
VUVAS-10X
-
A new ultraviolet spectrophotometer system for optical metrology just arrived at NASA Goddard! The VUVAS-10X spectrophotometer works best in the 90 to 160 nanometer wavelength range, also known as deep or vacuum ultraviolet (VUV) region. It uses a windowless hydrogen plasma light source and differential pump section to reach many wavelengths beyond those of conventional deuterium lamps. The source also works with other gases, or gas mixtures, for atomic spectral line emission from about 30 nanometers (double ionized Helium gas) up to the Visible light range. The new spectrophotometer system, McPherson VUVAS-10X, uses a one-meter focal length high-resolution monochromator with the special light source, scintillated detector and Model 121 goniometric sample chamber. The system is ideal for optical transmission, absorbance and specular reflectance at incident angles up to 60 degrees. This McPherson spectrophotometer system will help develop, inspect and qualify optical materials and coatings used for very high altitude and extraterrestrial space flight missions.
-
Product
PIEZONIZER
-
This is an air nozzle ionizer with a built-in ultra-compact high-voltage transformer that does not require high-voltage wiring. The high-voltage transformer uses a piezoelectric high-frequency output, which allows for better ion balance at lower voltages than conventional AC types, making it possible to generate ions very efficiently. There is almost no noise generated. The input operates on DC power only, making wiring easier. Furthermore, these ionizers come standard with a safety circuit that detects abnormalities in the high voltage. It is also possible to output an alarm in the event of an abnormality.
-
Product
Geiger Counters
-
A geiger counter detects nuclear radiation by measuring the emission of ionizing radiation of alpha particles, beta particles and gamma rays. Also referred to as a radiation detector, a geiger counter consists of two main elements: the processing electronics and the geiger tube. The geiger tube is filled with low-pressure inert gas like helium, argon or neon. If radioactive radiation occurs, the inert gas is ionized. An anode within the geiger tube registers the quantity of ionized particles numerically correlating with the strength of the radioactive radiation. The radioactivity measurement is then displayed on the LCD screen of the geiger counter or radiation detector.It is very important to measure radioactivity as well as to classify radioactivity values. For example, terrestrial gamma radiation is measured according to general values from 0.03 - 0.3 µSv/h (microsievert / hour). This "normal" oscillation range is conditioned by natural radioactive elements in the ground such as uranium and potassium. To calculate this factor, one must take into consideration cosmic radiation. For example, when considering cosmic radiation, the maximum radioactivity content at Schneefernerhaus, the highest-located German environmental research station, is approximately equal to 110 µSv/h.At PCE Instruments, you will find three types of geiger counter or raditation detection devices to help you measure radioactivity: 1) alpha radioactivity meters, 2) meters for detecting alpha, beta and gamma radioactivity and 3) radioactivity meters for human beings.