product
Pollution Monitoring/ Water Quality Sensing
PickMol
Detect organic contamination in water faster, cheaper and on the spot. Patented and validated solution that brings a new quality of pollution monitoring / fresh water sensing.
-
product
Air Pollution Multigas Calibrator
APMC-370
Dilution of gases with high accuracy and precision requires high quality MFC’s, especially for high dilution ratios and ranges. Consequently HORIBA’s APMC-370 is equipped with digital MFC’s. These MFC’s are factory calibrated, optional also with a special Polynomial Calibration. HORIBA Europe‘s APMC-370 is designed to calibrate gas analyzers manually, remotely controlled or automatically. It is installed in air pollution monitoring stations for quality assurance in the laboratory and also in the production of gas analyzers.
-
product
Flow Measurement for Liquids
We provide reliable flow measurement devices for clean, slight and heavily polluted media as well as a very wide variety of sensors. Our hydraulic flow measurement systems as well as our radar and ultrasound-based flow measurement systems are supplemented by hydrostatic or ultrasonic level measurements.
-
product
Stack Gas Analysis System
ENDA-5000 series
Continuous simultaneous and high-precision measurement of NOx, SO2, CO, CO2 and O2.HORIBA has over 100,000 CEM systems installed and 30 years of quality and experience. That is the base on which HORIBA's new ENDA-5000 series of stack-gas analysis systems are built. These systems have a small footprint and use cross-flow modulated non-dispersive infrared (NDIR) and magneto-pneumatic detectors that are inherently drift-free. The ENDA-5000 series are superior continuous analysis systems that perform reliably for difficult exhaust gas measurements, when measurement errors cannot be tolerated. This CEM series features a new intuitive touch panel that makes every operation available with the touch of a single button. The ENDA-5000 series systems are also designed for ease of maintenance. They are ideal for a variety of uses, including emissions monitoring from steam boilers, refuse incinerators, and electric power generation plants to assure pollution standards are being met.
-
product
Continuous Emission Monitoring System
CEMS
CEMS, the “Environmental Eye” for Source Emissions.A Continuous Emission Monitoring System (CEMS) is an integrated system to measure fuel flow, dust, and concentrations of air pollutants such as SO2, NOx, CO, CO2, THC and O2 in accordance with the applicable regulations for the emission source.
-
product
Clamp Meter, True RMS, 100 A AC, 600 V AC, 600 V DC, 17 mm Jaw Opening Max.
72-2985
The 72-2985 from Tenma is a mini clamp meter in orange and grey colour. It features high reliability, safety precision and compact design. Its resolution ratio is 1mA, maximum range has maximum range of 100A AC/DC, particular VFC start mode. Entering this mode can accurately measure voltage and current which has VFC frequency conversion. Voltage or current response display is true valid value. Whole range overload protection, reliable measurement accuracy and unique appearance design makes it an outstanding new generation functional electrician/electric power measurement instrument. This complies with EN 610101-1, 61010-2-032, 61010-2-033, pollution degree 2, measurement category: (CAT II 600V, CAT III 300V) and double insulation standards. Conforms to UL STD. 61010-1, 61010-2-032, 61010-2-33 certified to CSA STD. C22.2 NO. 61010-1, IEC STD 61010-2-032, 61010-2-033.
-
product
Resistive & Capacitive AC Load Bank
RCD
RCD AC load banks are used to test the REAL working condition of UPS, rectifier, inverter and etc who are loaded by non-linear or electronic load with non-constant resistance such as computer, networking equipments and etc. Through the accurate detection of its output and power quality, users could avoid the inadequate loading capacity or cause pollution to power grid, so as to guarantee supply security. JUNXY RCD load banks leading power factor loads are created to debug power supply system parameters such as its crest factor test.
-
product
Particle Counter
TES Electrical Electronic Corp.
Monitoring air pollutant souce from dust, pertochemical industry, steel-making plant, thermal power plant, restaurant, smoke, burning plnats, driving automobiles.The meter is a real time air quality monitor instrument used to monitor the concentration of PM2.5 humidity and temperature in the indoor environment.
-
product
Ambient Air Quality Monitoring System
AQMS
AQMS, the doctor for "Human Health"An Air Quality Monitoring Station (AQMS) is a system that measures metrological parameters such as wind speed, wind direction, rainfall, radiation, temperature, barometric pressure and ambient parameters. The AQMS also integrates a series of ambient analyzers to monitor the concentration of air pollutants (such as SO2, NOx, CO, O3, THC, PM, etc.), continuously. HORIBA also provides mobile monitoring stations that can be used to monitor ambient conditions at multiple sites.
-
product
Fixed Clamp-on Flowmeter
D118
Gentos Measurement & Control Co.
The D118 ultrasonic flowmeter is based on Tansit-time technology, which has ultra-high measurement accuracy. D118 uses an external clipped Transducer, which can collect flow data simply by clamping it on the outside of the pipe, and it will never come into contact with the fluid, and will not cause liquid pollution, pressure reduction, leakage, etc.
-
product
Continuous Gas Analyzer
CT5100
Emerson CT5000 series, providing the most comprehensive analysis available as it can detect down to sub ppm level for a range of components, while simplifying operation and significantly reducing costs. Unlike traditional continuous gas analyzers, the CT5100 can measure up to 12 critical component gases and potential pollutants simultaneously within a single system – meeting local, state, national, and international regulatory requirements.
-
product
Capacitor for AC Filtering
PECA4 (690V)
Lifasa - International Capacitors, SA
These capacitors are especially suitable for applications where high levels of AC voltage are required. The design of this series has been optimized for the manufacture of high performance AC filters for compensation equipment with high pollution such as UPS or wind turbines.
-
product
Bench Digital Multimeter, Calibrated, Data, 1 kV, 10 A, 3.8 Digit
72-1015 CAL D
The 72-1015 CAL D from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
product
CX4000 – FTIR Gas Analyzer
Gasmet CX4000 is an industrial multi-component FTIR gas analyzer for continuous emission monitoring applications, integrated into a Continuous Emissions Monitoring system (CEMS II e). It can be used to measure up to 50 components simultaneously, and additional gases can be easily added without any hardware changes. The corrosion-resistant sample cell is heated up to 180 °C, which makes CX4000 an ideal tool for analyzing trace concentrations of pollutants in wet, corrosive gas mixtures.
-
product
Residual Pollution Analysis System
Cleanalyzer
The Cleanalyzer is a high-end analytical system designed to examine particles on filters – a key procedure in performing reliable and reproducible evaluation of component cleanliness. High-resolution, optical zoom system (15µm and 5 µm version. High-resolution, fixed magnification optical system (35µm version).
-
product
Tailored for Measuring Emissions
CEMS solutions
SICK's CEMS solutions are analyzer solutions that have been specifically designed for measuring emissions at power plants, industrial facilities, or on ships. CEMS solutions can be used to measure pollutants and reference quantities and to perform data processing on the results in accordance with the relevant national or international legislation.
-
product
High Voltage Probe
HVP-40M
*DC 40KV CAT II Pollution 2*600MΩ Impedance*25KV ± 2%, 40KV ± 3%*T.C. 200 ppm/oC*Positive Polarity only.*Resolution 1KV*Need not power.*CE, TUV GS, UL, CUL, IEC1010
-
product
Laser Induced Incandescence (LII)
Soot is considered a hazardous pollutant emission and is typically a result of incomplete combustion processes, and thus is also related to combustion performance. Laser Induced Incandescence (LII) is a laser-optical measurement technique dedicated to soot diagnostics. LII can provide measurements of soot volume fraction, such as in Diesel engine exhaust, and even instantaneous images of soot distribution during formation inside a running IC engine.
-
product
New Resistivity Inversion Software
EarthImager 3D
AGI is proud to introduce the new EarthImager 3D resistivity and IP inversion software. This software inverts resistivity and IP data acquired with electrodes arranged in boreholes and/or on the surface and presents a 3D volume of inverted resistivity data with advanced volume rendering technique. The final resistivity or IP image-volume can be rotated in any orientation, zoomed in and out, and translated to anywhere inside the image window in order to see the volume of interest in detail. Colors representing areas of less interest can be made transparent so that the shape of a pollution plume, for example, can be visible. With EarthImager, 3D resistivity inversion can be as easy as two steps: Read Data and Start Inversion with only a few mouse clicks.
-
product
Oil Quality Meter
Cooking oil is the mainly energy and nutrition source, and the cookingmaterial for daily life. Fried food is also favored as its unique taste . Withphysical and chemical reaction during the high-temp cooking process ,toxical chemicals will be produced. Currently, the traditional testing methodon cooking oil is mainly chemical method which is commonly used andconducted by professionals in the lab. But the lab oratory process alwaysproduces pollution and unnecessary waste . The Total Polar Material (TPM)values is the only acceptable standard which us ed for cooking oil testing.OS-27 is designed for cooking oil testing with safety and efficiency. It is ableto test total polar material (TPM) values in minutes and suitable for all kindsof cooking oil within high operation temperature.
-
product
High Voltage Probe
HVP-40DM
*DC 40KV CAT II Pollution 2.*2000MΩ Impedance.*3999 LCD display.*Accuracy 1.0% full range.*T.C. 100 ppm/oC*400V/4KV/40KV, 3 range.*Resolution 0.1V/1V/10V.*PEAK HOLD, Auto power off.*CE, TUV GS, UL, CUL, IEC1010
-
product
Air Quality Measurement
Air pollution measurement is the process of collecting and measuring the components of air pollution, notably gases and particulates. The earliest devices used to measure pollution include rain gauges, Ringelmann charts for measuring smoke, and simple soot and dust collectors known as deposit gauges.
-
product
Sound Level Meters
Shenzhen Graigar Technology Co.,Ltd.
A sound level meter is an instrument that can measure sound level, commonly used in noise pollution studies for the quantification of different kinds of noise, especially for industrial, environmental and aircraft noise.
-
product
Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.
72-7226 CAL D
The 72-7226 CAL D from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.
-
product
Element 1 Power Systems
The fuel cell will change our lives as much as the computer it powers and the internal combustion engine it replaces. The future of power and transportation will change dramatically when fuel cells become the main producers of clean energy. The car will no longer be an environmental burden, and the electrical grid will be subdivided to the neighborhood and building level. The quality and reliability of this alternative energy source will be superior to the current grid design. Fuel cells and hydrogen technology will make all of this possible, and with little or no pollution.
-
product
Noise Control And Acoustical Consulting Services
Our acoustical consultants use the latest and most advanced noise prediction and modeling software, precision sound measurement equipment and detailed acoustical analysis that enable us to help our clients achieve their project's noise requirements and goals. Contact us before your noise challenges become noise pollution problems.
-
product
Noise Control And Acoustical Consulting Services
Our acoustical consultants use the latest and most advanced noise prediction and modeling software, precision sound measurement equipment and detailed acoustical analysis that enable us to help our clients achieve their project's noise requirements and goals. Contact us before your noise challenges become noise pollution problems.
-
product
Differential Pressure Meters, Micromanometers
Unprecedented differential pressure measurement accuracy (yet a wide range) for critical pollutant pathway monitoring, ventilation assessment, filter performance testing, general HVAC measurement and many other applications. GrayWolf AdvancedSense meters include auto-ranging dual DP sensors, as well as auto-zeroing (to maintain low-end precision). GrayWolf DP instruments offer broad measurement ranges, yet exceptional sensitivity. They may be utilized for spot checks and for long-term trending of a variety of pressure measurement applications that require high reliability. Choose from the cutting edge AdvancedSense Pro, AdvancedSense BE or the new Zephyr III Meter (which replaces the workhorse “classical” Zephyr II in July 2020).