Magnet
Attract iron and are surrounded by a magnetic field.
-
product
Demagnetize Bar Tube Or Wire Material Ranging Up To 8.5” (215mm) Diameter During Production
Demagnetizers
*Offers effective demagnetizing even for problem alloys.*Used in metal manufacturing plants to eliminate residual magnetism in test material after the eddy current test (ECT) is completed.*Can also be used for similar applications where high-speed reduction of residual magnetism is required.*Several models are available to meet your unique production needs.*Experienced MAC® Field Engineers can recommend the most appropriate demagnetizing equipment for your applications.
-
product
Handheld Gaussmeter
HGM09
Data storage on a personal computer via keystroke. The HGM09s is easy to use and has a good price/performance ratio. The handheld gaussmeter HGM09s is used to measure magnetic DC and AC fields. The measurands are flux density in Tesla or Gauss and the field strength in Amps per meter.
-
product
Quantum Hall Resistance System
Measurements International Ltd.
Quantum Hall System, System Accuracy to < 0.003 ppm with CCC Model 6200A, System Accuracy to < 0.015 ppm with DCC Model 6020Q, 5 Tesla Standard System Magnet, Stable Controlled Sample Environment, Base Temperature < 3.6 K, Low Operating Costs, Direct Transfer to 100 Ω, 1 kΩ, 10 kΩ, and 100 Ω Standards, System Range 0.1 Ω to 100 kΩ, Graphene Device Values 1 kΩ, 10 kΩ, 12.9064037 kΩ and 100 kΩ, Triple Sample Device Mounting.
-
product
Soft Magnetic Tester
Model SMT-700
KJS Associates/Magnetic Instrumentation offers the Model SMT-700 computer-automated magnetic test station for measuring the DC and AC magnetization curves, coercive field strength, and core-loss characteristics of magnetically soft materials, including: Si-Fe, Fe-Co, Fe, stainless steel, Ni-Fe alloys, soft ferrites and others. This modern line of laboratory instruments is designed specifically for accuracy, reliability, and ease-of-use.
-
product
Level Measurement
Displacer level gauge for liquids from KOBOLD Instruments operates on the Archimedes principle. The level gauge's displacer tube rests inside the tank and is connected to the measuring unit via a spring. As liquid level increases, the buoyant forces of the liquid act on the displacer tube to reduce spring tension, allowing the spring to expand. The spring connects to a magnetic actuator, and the motion of the actuator is picked up by a magnetically linked indicator to yield the tank level measurement. The displacer level gauge is calibrated at the factory for the user's specified liquid density. Special designs with higher pressure or temperature ratings, as well as those made of exotic materials, are always available on request.
-
product
Magnetic Field Cancelling System
MR-3
3-axis magnetic field cancelling system for electron microscopes (SEM and TEM), electron and ion beam experiments, nanotechnology, biomagnetic investigations, etc. High reliability through rugged analog design. No tedious programming, no chrashs. More than 1000 MR-3 systems sold worldwide.
-
product
Power Inductor
Is a passive two-terminal electrical component that stores energy in a magnetic field when electric current flows through it.
-
product
Eddy Current Testing
Shanghai Xianda Denshijiki Industry Co.,Ltd
And the eddy current generated on the specimen by the specimen by the action of the magnetic field can not be detected (defect) and the change due to the influence of the material is detected.
-
product
3 Axis Digital Fluxgate Vector Magnetometer
WFG-D-120A
The Model WFG-D-120 magnetometer is a tri-axial vector magnetometer system with a high-speed digital interface that can transmit XYZ magnetic field values at up to 140 times per second.
-
product
Single Axis AC Magnetic Field Sensor
MGC-1
Macintyre Electronic Design Associa
The MGC-1 is a low noise high sensitivity single axis AC magnetic field sensor used for the measurement of audio frequency fields. Because of its innovative design, the MGC-1 amplitude response is insensitive to the frequency of the field over its 5 Hz to 10 kHz frequency band. Accuracy at 1 kHz is ±1%, and the amplitude response stays within 2 dB peak-to-peak over the bandwidth.
-
product
Coating Thickness Gauge
CM8855
It meets the standards of both ISO2178 and ISO 2361 as well as DIN, ASTMand BS. It can be used both in the laboratory and in harsh field conditions. The F probes measure the thickness of non-magnetic materials (e.g. paint,plastic, porcelain enamel, copper, zinc, aluminum , chrome etc.) on magneticmaterials (e.g. iron, nickel etc.) . often used to measure the thickness ofgalvanizing layer, lacquer layer,porcelain enamel layer, phosphidelayer, copper tile, aluminum tile, some alloy tile, paper etc. The N probes measure the thickness of non - magnetic coatings on non-magnetic metals .It is used on anodizing, varnish, paint, enamel,plastic coatings, powder, etc. appliedto aluminum, brass, non-magnetic stainless steel, etc. Automatic substrate recognition. Manual or automatic shut down. Two measurement mode: Single and Continuous Wide measuring range and high resolution. Metric/Imperial conversion. Digital backlit display gives exact reading with no guessing or errors. Can communicate with PC computer for statistics and printing by the optional cable. Can store 99 groups of measurements. Statistics is available.2.SPECIFICATIONSDisplay: 4 digits LCD, backlitRange: 0~1250 μm/0~50mil (other ranges can be specified )Min.radius workpiece: F: Convex 1.5mm/Concave 25mmN: Convex 3mm/ Concave 50mmMin. measuring area: 6mmMin.Sample thickness : 0.3mmResolution: 0.1 μm (0~99.9μm);1 μm (over 100μm)Accuracy: ±1~3%n or 2.5 μm or 0.1mil(Whichever is the greater)Bttery Indicator: Low batter indicator.PC interface: with RS-232C interfacePower supply: 2x1.5 AAA(UM-4) batteryOperating condition: Temp. 0~50℃ .Humidity <95% .Size: 126x65x35 mm; 5.0x2.6x1.6 inchWeight: about 81g(not including batteries)Standard accessories:Carrying case ...................1 pc.Operation manual ............ 1 pc.F probe in built .................1 pc.NF probe in built...............1 pc.Calibration foils ..............1set.Substrate (Iron) ................1 pc.Substrate (Aluminium)......1 pc.Optional accessories: RS-232C cable & software:1.USB adaptor for RS-232C2.Bluetooth interface
-
product
Coating Thickness Meter for Automobiles - Ferrous and Non-Ferrous Substrates
CM8828FN
- Operating principle: magnetic induction/eddy current (F/NF)- Measuring range:0-1250um/0-50mil- Resolution; 0.1/1- Accuracy: 卤1-3%n or 卤2.5um- Min. measuring area: 6mm - Min. sample thickness: 0.3mm- Battery indicator: low battery indicator- Metric/ imperial: convertible- Power supply: 4x1.5V AAA(UM-4)battery- Auto power off- Operating conditions:0-+45鈩?/span>(32鈩?/span>-104鈩?/span>),鈮?0%RH- Dimensions: 126x65x27mm- weight: 81g(not including battery)- Optional accessories: other range 0-200um to 15000um
-
product
Three Loop Antenna
VVLA-30M
The three loop antenna VVLA-30M is a standard measurement antenna according to CISPR15-2005/GB17743-2007 standard
, it can work with LISUN EMI-9KA / EMI- 9KB EMI Receiver System for EUT magnetic field radiation measurement between X, Y and Z planes. The antenna measurement is accurate, switch conveniently and it can completely replace imported products. -
product
Neon Transmitter
Shanghai Yiya Electronic Instrument Co., Ltd.
Asphalt resin filled and vacuum potted. Patented magnetic core at low consumption. Heavey duty metal box and coated power. User Friendly-Adapts to most grounding situations.
-
product
Wideband EMF Measuring Equipment
Measuring equipment for electromagnetic fields (EMF) for demonstrating safety and environmental compatibility. The devices measure the total electric and/or magnetic field strength and automatically compare it with limit values specified by national and international bodies in standards or directives.
-
product
Land Platform Inertial Navigation Unit
Epsilon™
Versatile, Epsilon™ family provides advanced applications, even in GNSS denied environment: navigation (position & heading), aiming aid, driving aid. It covers all tactical applications from logistic to infantry fighting vehicles, as well as main battle tank.- Can be integrated with small artillery caliber to provide precision pointing- Connectable to any Battle Management system- Immune to magnetic disturbances
-
product
Magnetic Particle Inspection(MPI)
Magnetic particle inspection is an inspection method used to identify defects on the surface of ferromagnetic materials by running a magnetic current through it.
-
product
Electromagnetic Flow Meters
Magnetic flow meters, also known as electromagnetic flow meters or mag meters, are often selected because they are obstruction less, cost-effective, bi-directional, and highly accurate flow meters.
-
product
Portable Thickness Gauge
Magna-Mike 8600
The Magna-Mike® 8600 is a portable thickness gauge that uses a simple magnetic method to make reliable and repeatable measurements on nonferrous materials. Operation of the Magna-Mike is very simple. Measurements are made when its magnetic probe is held or scanned on one side of the test material and a small target ball (or disk or wire) is placed on the opposite side or dropped inside a container.
-
product
Precision Helmholtz Coils
A precision Helmholtz coil set is suitable for use with all types of permanent magnets. Constructed out of aluminum and brass with fully shielded coils, the HCP is a hand-operated, sample rotation mechanism with precise 180-degree rotation built in.
-
product
EMC Near Field Probes
TBPS01
The TBPS01 EMC near field probes H20, H10, H5 and E5 are magnetic field (H) and electric field (E) probes for radiated emissions EMC pre-compliance measurements. The probes are used in the near field of sources of electromagnetic radiation.
-
product
Magnetic Particle Inspection Systems for Non-Destructive Testing (NDT)
VERIFY SURFACE AND SUBSURFACE STRUCTURAL INTEGRITY IN: Industrial Crankshafts, Ferrous Parts, Aircraft Components, Landing Gear Components.
-
product
Zero Gauss Chamber
IDR-800
Integrity Design and Reseach Corp.
Two cylindrical tubes are equal in length (12"), one is inside the other, both of them are closed at one end. At the other end, the inner tube is open (Radius=1").The cylindrical tubes are made from high permeability material.The magnetic field inside the inner tube is almost annulled.Optional use with the Geomagnetometer IDR-321 to provide a zero gauss (magnetic field-free environment) reference, enabling you to take absolute readings of the ambient magnetic field (the Earth's magnetic field is typically around 500 mG)
-
product
L.V.D.T Products
Columbia Research Laboratories
Columbia's L.V.D.T.'s are designed for the most demanding high temperature military and industrial applications where maximum life under adverse conditions is required. The corrosion resistant stainless steel housing provides effective shielding to contain the magnetic flux within the transformer, as well as providing protection against external magnetic fields. Conservative design permits the use of these transducers well beyond their specific linear range with minimum loss of accuracy.
-
product
Through Hole type DC Current Sensor/for DC Leakage Current Measurements
DCZCT-20M
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement for solar power system*Least affection from the magnetization of core and temperature fluctuation*DC leakage current measurements*Current measurements for small DC motor*Convenient +5V single polarity power supply
-
product
Level Monitoring
Magnetic level switches are used for the monitoring and control of liquid level in tanks. These level switches are specifically manufactured to customer specifications. The float switches are manufactured with a hermetically sealed contact which is located within the guide tube. The float sliding on the tube contains a ring magnet which activates the sealed contact in a non-contacting fashion. The sealed contacts are available as SPST (N/O or N/C) or SPDT (N/O + N/C). The float sliding up and down on the guide tube is the only moving part on the M-series magnetic float switches.
-
product
Partial Discharge Testing Of Transformer & Localization System
AE-150™
The is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors' data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors.
-
product
Recording Ammeter
Amcorder
The Amcorder uses the same sensor technology as the original Ampstik. The True RMS inductive sensor does not use magnetic materials and has no moving parts. The opening of the sensor is electronically closed and external currents are electronically rejected. The accuracy, external current reject, and range of currents measured by the patented amp sensor substantially exceed the performance of the best clamp-on sensors. The key feature of the unit is the ability to leave it deployed on the line to record average current readings every 15 minutes for 30+ days. It easily attaches to the line with a standard shotgun style hot-stick. Once on the line, it immediately begins to collect and record the current load on the line.
-
product
AC/DC Clamp Milliammeter (CE)
M-700
MULTI MEASURING INSTRUMENTS Co., Ltd.
*High sensitive for low range leakage current.*Suitable for measurement of 4-20mA DC controlled circuit.*DC mV analog signal output.*Lowest influence from Magnetization and Terrestrial magnetism.*Wide measuring ranges up to DC 1000mA and AC 10A.