High Speed Data Acquisition
-
product
CC15010X, 10 MHz, 150 A Current Oscilloscope Probe
786849-01
The CC15010X, or Hioki 3274, is a clamp-on current probe that offers a wide DC to 10 MHz bandwidth and 150 A of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
product
Brute High Current Probe
P4301-1R
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
product
4AO/4DI Modbus RTU Remote I/O
ND-6124
The NuDAM modules provide direct communications with a wide variety of sensors; perform signal conditioning, scaling, linearization and conversion; can acquire measurements of temperature, pressure, flow, voltage, current; and handle multiple digital signal types broadly used in IoT and other industrial applications, such as facility monitoring, environment monitoring, and industrial process control. The new ND-6117, ND-6124, ND-6150, and ND-6160 modules feature Modbus/RTU as the best remote data transmission protocol, which provides customers a comprehensive product offering.
-
product
Standard 3.06 (86.70) - 4.00 (113.40) RF Probe For SMA Connectors
CSP-30ES-013
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Return Loss @ -20dB (GHz): 22.00Test Center (mil): 328Test Center (mm): 8.33Recommended Travel (mil): 100Recommended Travel (mm): 2.54Full Travel (mil): 200Full Travel (mm): 5.08Overall Length (mil): 1,033Overall Length (mm): 26.24Rec. Mounting Hole Size (mil): 297Rec. Mounting Hole Size (mm): 7.54
-
product
Active Differential Probe, 100 kHz to 7 GHz
U1818A
The Keysight U1818A 100 kHz to 7 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818A allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
product
Standard- 27.20 (771.00) - 64.00 (1814.00) Godzilla High Current Probe
HC375F-4
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
product
High-Voltage Differential Probe, 200 MHz
N2805A
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.
-
product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40G-021
Your product description goes here.
-
product
CC30100X, 100 MHz, 30 Arms Current Oscilloscope Probe
785562-01
The CC30100X, or Hioki 3276, is a clamp-on current probe that offers a wide DC to 100 MHz bandwidth and 30 Arms of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
product
Data Acquisition System - 3U 1-Slot
DAQ-31CP0G
The DAQ-31CP0G is a preconfigured rugged system with a high-performance, low power ARM® Cortex®-A9 processor. It is ideally suited to support a multitude of data acquisition applications that require high-density, multichannel, programmable communications consisting of: ARINC 429/575; Dual-Redundant, Quad Channel MIL-STD-1553B; CANBus (CAN 2.0 A&B or J1939) and Dual-Port Gig-E Ethernet.
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
Dual Function Slot MOSA Data Concentrator Unit (DCU)
NIU2A-DCU-01
NIU2A-DCU-01 is a Modular Open Systems Approach (MOSA) Data Concentrator Unit with low power high performance ARM Cortex -A9 processing. 512 MB RAM, 32 GB SATA Flash, 2 x 10/100/1000Base-T Ethernet and optional Fiber Optic Ethernet support
-
product
High-Voltage Differential Probe, 70 MHz
N2891A
Use the N2891A 70-MHz high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2891A differential probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to ±7000 V of differential and common mode voltage.
-
product
15-CH Isolated Digital Input Module
ND-6054
- Channels: 15- Isolation Voltage: 5000 VRMS- Switching Level: with 24 V common power. Low (0): 22 V min.; High (1): 0-22 V- Programmable input polarity
-
product
CC05120X, 120 MHz, 5 Arms Current Oscilloscope Probe
786847-01
The CC05120X, or Hioki CT6701, is a clamp-on current probe that offers a wide DC to 120 MHz bandwidth and 5 Arms of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
product
Low-Cost 16-Bit Multi-Function DAQ Card with 2-CH Encoder Input
PCI-9221
The ADLINK PCI-9221 is a 16-bit high-resolution and low-cost multi-function DAQ card, with 16-CH singleended or 8-CH differential input capable of up to 250 kS/s sampling rate. In addition, the PCI-9221 comes with a 2-CH 16-bit static analog output and programmable function I/O. The software-programmable function I/O supports a variety of applications, including TTL digital I/O, general-purpose timer/counter, encoder input, and PWM output. The flexible function I/O makes the PCI-9221 the best single-board solution for combined data acquisition and simple motion control functionalities. Ideal for manufacturing, laboratory research, and factory automation, the PCI-9221 comes with all the functions you need at an affordable price.
-
product
4-CH 24-Bit 128kS/s Dynamic Signal Acquisition USB 2.0 Module
USB-2405
The USB-2405 is a 24-bit high-performance dynamic signal acquisition USB module equipped with 4 analog input channels providing simultaneous-sampling at up to 128 kS/s per channel. The USB-2405 also features software selectable AC or DC coupling input configuration and built-in high precision 2 mA excitation current to measure integrated electronic piezoelectric (IEPE) sensors such as accelerometers and microphones.
-
product
Standard -1.44 ( 41.00) - 4.50 (128.00)High Current Probe
HCP-13B
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13P
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13A
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Industrial Data Acquisition Module for embedded systems with PCIe/104 OneBank expansion
PX1-I440-ADC
The PX1-I440-ADC is an industrial data acquisition module for embedded systems with PCIe/104 OneBank expansion. This module features eight differential ADC (analog-to-digital converter) inputs based on the Analog Devices LTC2335-16 ADC. Analog to digital inputs terminate to a single 20-pin box header connector.
-
product
Godzilla High Current Probe, 100 Amp
HC375
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03B-006
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Dielectric VTE Rating (k VAC): 1Nominal Impedance (Ohms): 50Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
product
Standard - 1.44 (41.00 - 4.50 (128.00) High Current Probe
HCP-13H
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Data Acquisition System
DAQ
Data Acquisition (DAQ) systems are used to collect information for the purpose of documenting or analyzing an electrical or physical phenomenon, for example: temperature or pressure. They serve as a focal point in tying a wide variety of sensors together that indicate temperature, flow, level or pressure. The sensors convert a physical occurrence into a measurable electrical signal, which can be factored into command and control decisions. These high-speed DAQ systems feature different analog and digital input and output modules that can be used with a wide range of signal types including 4-20 mA current, thermocouples, and RTDs.
-
product
8AI Modbus RS-485 Remote I/O
ND-6117
The NuDAM modules provide direct communications with a wide variety of sensors; perform signal conditioning, scaling, linearization and conversion; can acquire measurements of temperature, pressure, flow, voltage, current; and handle multiple digital signal types broadly used in IoT and other industrial applications, such as facility monitoring, environment monitoring, and industrial process control. The new ND-6117, ND-6124, ND-6150, and ND-6160 modules feature Modbus/RTU as the best remote data transmission protocol, which provides customers a comprehensive product offering.
-
product
64-Channel 500kSa/s USB Modular Multifunction Data Acquisition
U2356A
The U2356A offers multifunction capabilities in a module. It can be used like a digital multimeter in polling mode. It can be transformed to be a simple scope using the continuous mode with simple triggering capabilities. No matter if it is used as a standalone module or when plugged into a U2781A USB modular instrument chassis, the synchronization and triggering capabilities allow great flexibility in making the desired measurements. With the analog output being able to send out predefined or arbitrary waveforms make this a good tool when closed loop feedback or stimulus is required. The digital IO channels allows for closed loop control through connections to switches, relays and solenoids. The burst mode enables the U2356A to simulate simultaneous analog input acquisition.
-
product
Active Differential Probe, 100 kHz to 12 GHz
U1818B
The Keysight U1818B 100 kHz to 12 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818B allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
product
AC / DC Current Probe, 100 KHz, 100 A
1146B
The Keysight 1146B AC / DC probe provides accurate display and measurement of currents up to 100 A DC or peak AC / DC to 100 kHz without breaking the circuit. The 1146B AC / DC probe has hall-effect sensor technology to measure AC and DC signals. It is compatible with any Keysight oscilloscope with 0.2 to 0.5 V / div sensitivity and 1 MΩ BNC input.
-
product
Analog Output Module
ND-6021
- Voltage Output: 0 to 10 V- Current Output: 0 to 20 mA, 4 to 20 mA- Output Isolation: 5000 VRMS- Resolution: 12-bit resolution- Accuracy: ± 0.1% of FSR (current); ± 0.2% of FSR (voltage)