Thermocouple Simulators
-
product
Thermocouple Calibrators
Practical Instrument Electronics, Inc.
PIE has a thermocouple calibrator to fit your needs from the PIE 520B single type thermocouple simulator to the advanced troubleshooting capabilities of the PIE 422Plus. Have you had issues in the past where your thermocouple calibrator wouldn’t work with some of the instruments in your plant? Our thermocouple calibrators are guaranteed to be compatible with all process thermocouple inputs including all brands of smart temperature transmitters, PLC input cards, DCS systems and multichannel recorders.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 32 Channel
41-761-001
The 41-761-001 is a low voltage 32-channel output module ideal for simulating theoperation of a thermocouple, also available with 24, 16 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 8 Channel
41-761-004
The use of two wire outputs and isolation from ground ensures that the 41-761 can be used to accurately simulate low voltages even in the presence of common mode voltages in the system. Each Vcold connection is independent permitting the 41-761 to be connected to multiple cold junctions.
-
product
PXI Millivolt Thermocouple Simulator Module - 8 Channel
41-760-004
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 26 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
product
16-Channel VME Analog Output/Thermocouple Simulator Module
V470
The V470 is a 6U VME module that provides sixteen independent, isolated analog outputs that may be user-programmed to operate as voltage outputs or thermocouple simulators. Users may write temperature or voltage values at VMEbus speed, and the microprocessor will transparently do all necessary calculations and update the channel electronics.
-
product
Thermocouple Simulator Module for SLSC
Bloomy’s 8-Channel Thermocouple Simulator Module provides eight channels of galvanically-isolated thermocouple simulation and simulates types E, J, K, M, N, and T thermocouples. High-precision digital-to-analog converters which are isolated from each other and from system power provide sub-microvolt resolution and accuracy. Built-in switching provides open-circuit faults as well as switching to system calibration resources.
-
product
PXI Millivolt Thermocouple Simulator Module - 16 Channel
41-760-003
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 24 Channel
41-761-002
The 41-761-002 is a low voltage 24-channel output module ideal for simulating theoperation of a thermocouple, also available with 32, 16 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
product
PXI Millivolt Thermocouple Simulator Module - 32 Channel
41-760-001
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 16 Channel
41-761-003
The 41-761-003 is a low voltage 16-channel output module ideal for simulating theoperation of a thermocouple, also available with 32, 24 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
product
PXI Simulation Modules For Sensor Simulation
PXI simulation solutions for sensor simulation, including PXI Programmable Resistors—ideal for the simulation of resistive sensors and PXI Thermocouple Simulators—these provide multiple low-voltage sources ideal for simulating the operation of a thermocouple. Take a look below for all of our PXI Simulation Solutions, we also offer some of these in PCI format as well . All of our PXI simulation cards are supplied with comprehensive software drivers for Windows® XP/Vista/7/8, Lab Windows / CVI and LabView. The Pickering IVI drivers also fully support National Instruments' Switch Executive.
-
product
PXI Thermocouple Simulators
Our PXI Millivolt Thermocouple Simulator modules provide 32, 24, 16 or 8 channels of accurate low sources. They are ideal for the simulation of thermocouples and can be used for sensor emulation in ECU testing. The channels can be operated with one of three voltage ranges covering most thermocouple types. We can also supply connection solutions allowing the easy integration of the Thermocouple Simulator into your test system.
-
product
Compensation Block for Thermocouple Simulator Modules
40-965-912
The Compensation Block is a accessory specifically designed for the 41-760 and 41-761 Millivolt Thermocouple Simulator modules. This block will give the user the temperature of the front panel junction of the module to cabling. This data can then be combined with other factors, temperature on the other end of the cable for example, to compensate the thermocouple hence increase the accuracy.
-
product
PXI Millivolt Thermocouple Simulators
Series 41-760
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channelseach channel providing a low-voltage output across two connector pins capable of providing 20mV with 0.7V resolution, 50mV with 1.7V resolution and 100mV with 3.3V resolution, covering most thermocouple types. These thermocouple simulators use two wire outputs with a remote output reference sense to ensure the modules deliver accurate low-level voltages, even if the system has common mode voltages present. In addition, each simulation channel is also able to provide an open circuit setting to simulate faulty wiring connections to a sensor.
-
product
PXI Millivolt Thermocouple Simulator Module - 24 Channel
41-760-002
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
product
Calibration Cable, 78-pin D-type, Thermocouple Simulator Modules
40-975-078-1m
This cable assembly is specifically designed to connect to the 78-Pin D-Type port on the front panel of Pickering Interfaces Thermocouple Simulator Modules 41-760 and 41-761 enabling calibration via an external DMM.
-
product
E-Type Thermocouple, 32°F to 900°F Temperature Sensor
745690-E001
E-Type Thermocouple, 32°F to 900°F Temperature Sensor - The E-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the E-Type Thermocouple and acquire synchronized temperature data in units of degrees. The E-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
product
RTD Simulator PCI Card 6-Channel PT1000
50-262-102
This RTD Simulator is a PCI card that supports 6 channels of RTD simulation. The card can provides a setting resolution of <90mΩ (also available in <8mΩ - PT100) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
product
Single Stream STANAG3910 Electrica lTest And Simulation Module – Rafale – for PCI
APXX3910-EN
Single Stream STANAG3910 Test and Simulation Module – Rafale – for PCI with 1 dual redundant HS/LS channel and onboard Electrical Front End. The APXX3910-EN is a functional replacement for model APX3910-EN.
-
product
Synchro/Resolver Simulator, Programmable
5330A
NAI's 5330A Synchro/Resolver Simulator is a rack-mount or bench-top instrument featuring integrated touch-screen controls and input terminals. This model represents a major step forward as it uses digital technology to produce Synchro and Resolver outputs. Improved flexibility is provided by two fully independent outputs that can be used to simulate two separate Synchro or Resolver signals simultaneously, or can be combined to operate as two-speed outputs. The versatility of this device has been substantially increased by incorporating dynamic modes that enable servo systems to be tested under various simulated stringent field conditions.
-
product
PXI RTD Simulator Module, 24 Channel, PT1000
40-263-003
The 40-263-003 is a 24-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
3U cPCI Synchro/Resolver Simulation Board
75DS2
NAI’s 75DS2 is a Synchro/Resolver Simulation Board with four independent, isolated channels. These channels can incorporate up to four Digital-to-Synchro/Resolver Simulation Converters with 1.5, 2.2, or 3 VA drive capability, or either two or four Digital-to-LVDT/RVDT Simulation Converters. One of the outputs on each channel can be grounded without affecting performance.
-
product
ARINC825 (CAN Bus) Test & Simulation Module for PCI With 2 Or 4 CAN Bus Nodes
ACP825-x
ARINC825 (CAN bus) Test & Simulation module for PCI with 2 or 4 electrically isolated CAN bus nodes operating concurrently at CAN bus high speed bit rate of up to 1Mbit/s. The ACP825-x PCI card can work either with full functionality as an active CAN node for testing and simulating or in Listening Only mode for monitoring and recording purposes.
-
product
PXI RTD Simulator Module, 16 Channel, PT500
40-263-202
The 40-263-202 is a 16-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
Thermocouple, Contact, Receiver, Alumel, Type K (°C)
610113132
Primary mating contact 610113134.Thermocouple contacts are manufactured from chromel or alumel alloys and color-coded for easy identification. Contacts are crimp terminated and easily inserted into the connector module. They can be readily removed from the connector module using a special removal tool.
-
product
Programmable S/R Standard & Simulator
5300
NAI’s 5300 Synchro/Resolver Standard & Simulator is a laboratory-grade, programmable instrument. This model can be used as a true Synchro/Resolver standard for calibrating and testing Automatic Test Equipment (ATE) for Calibration/Metrology Labs, and for Engineering Design and Production Test environments. It can also be used to measure Angle Position Indicators (API) and Synchro-to-Digital converters for static or dynamic characteristics. This model also may use an external reference waveform.
-
product
LED Load Simulator
63110A/ 63113A/63115A
As shown on the V-I curve in figure 1, the LED has a forward voltage VF and a operating resistance (Rd). When using a resistor as loading, the V-I curve of the resistor is not able to simulate the V-I curve of the LED as shown in blue on figure 1. This may cause the LED driver to not start up due to the difference in V-I characteristic between the resistors and the LEDs. When using Electronic Loads, the CR and CV mode settings are set for when the LED is under stable operation and therefore, is unable to simulate turn on or PWM brightness control characteristics. This may cause the LED driver to function improperly or trigger it’s protection circuits. These testing requirements can be achieved when using a LEDs as a load; however, issues regarding the LED aging as well as different LED drivers may require different types of LEDs or a number of LEDs. This makes it inconvenient for mass production testing.
-
product
Thermocouple, Contact, ITA, Alumel, Type K (°C)
610113134
Primary mating contact 610113132.Thermocouple contacts are manufactured from chromel or alumel alloys and color-coded for easy identification. Contacts are crimp terminated and easily inserted into the connector module. They can be readily removed from the connector module using a special removal tool.
-
product
Single Function MIL-STD-1553 Test & Simulation PCIe Card
ASE1553M-x
Single Function MIL-STD-1553 Test and Simulation module for PCIe with 1, 2 or 4 dual redundant streams.





























