Current Transducers
-
Product
Current Measurement Board
MS 1814
-
*Maximum DC Voltage Rating: 15V to 75V*Maximum DC Current: 5A*Output Voltage per 1A: 1V*Maximum AC Current: 5A*Operating Temperature: 0°C to 55°C*Storage Temperature: -20°C to +65°C*90% Relative Humidity (Non-condensing)*No. of DC Current Channels: 9*No. of AC Current Channels: 4nos*Maximum AC Voltage Rating: 230VAC*Channel Selection: Through 16 CH Analog MUX*Measurement Error Over Full Temperature Range: 5%*Type of Output: Proportional voltages*Maximum Voltage Drop across Series Resistor Full Scale Measurement: 0.05VDC
-
Product
Compact Eddy Current Sensor System
eddyNCDT 3005
-
Compact and robust design. - Temperature compensation up to 180C. High precision measurement accuracy. High frequency response. Sensor for ferro- and non-ferromagnetic targets. Easy to use (plug & play). Perfect for machine integration.
-
Product
High Frequency Current Transformer
HFCT
-
The HFCT is a high frequency current transformer designed specifically for picking up partial discharge signals. It has a split core ferrite to allow retrospective fitting to earth straps without the need for disconnection. The durable body has a hinge and a quick release latch, making use quick and easy. The HFCT is constructed with an aluminium body to provide RF shielding and improved performance in noisy environments.
-
Product
Zero Phase Current Transformer
MZL-30
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
Split-core type for measuring zero phase current
-
Product
Electrical Power Transducers
-
Manufactured for utilities since 1969, TransData Power Transducers are used for measuring AC and DC power variables in Substation, Generation, Load Control and Industrial applications where ±1ma or 4-20mA analog signal are required by the SCADA/Energy Management System. Models are available for measuring Current, AC Voltage, DC Battery Voltage, Watts, VARs, Frequency and more.
-
Product
Current Caliper
KH23101
-
Beijing KeHuan Century EMC Technology Co,.LTD
The KH23101 current caliper is a toroidal transformer used to measure EMI current. When measuring, the caliper does not directly touch the electrical conductor or the cable under test. The conductor passing through the caliper window is used as the single-turn primary wire of the transformer, and the secondary is designed to be multi-turn. Use with 50 Ω receiving system (such as EMI electromagnetic interference field strength meter or spectrum analyzer). In order to facilitate installation and rapid measurement of EMI current, it is designed as a caliper that can be opened.
-
Product
Transducers and Probes
-
Olympus NDT probes and transducers are high-quality inspection equipment available in a range of frequencies, configurations, connection styles, and cable types. All our probes and transducers are lightweight but solidly constructed.
-
Product
Current Clamps and Sensors
-
Are designed for measuring leakage current diverted towards the earth. It enables the fault to be located or anticipated without disconnecting the equipment linked. It is specially designed to detect low fault currentson power circuits.
-
Product
Multi Circuit Leakage Current Monitor
MCM-8000
-
By connecting optional CT sensors, the instrument can measure and memorize leakage current of 8 circuits at the same time and the memorized data can be seen even during measurement.
-
Product
True RMS Current Clamps
-
PeakTech Prüf- und Messtechnik GmbH
Current clamps are ideal for current measurement in electrical systems and control cabinets, since only single wires are guided through the clamp jaws for contact-free current measurement and no electrical connections have to be disconnected. In addition, this model has extensive multimeter functions for voltage, resistance, frequency, capacitance and temperature measurement.
-
Product
High Frequency Current Transformer
HFCT Ø 140mm
-
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
Product
Integrated Two-Stage Current Sensors
-
If ultra-low noise performance is required, our integrated two stage devices are the number one choice. With input inductances from 24 nH to 1.8 µH and a flux-noise level as low as 0.8 µPhi0/sqrt(Hz) an energy resolution of about 45 h is attained. The devices consist of a 16 SQUID series array as amplifier stage and a single front-end SQUID.
-
Product
AC Current Transformers
-
CR Magnetics supplies an extensive line of toroidal current transformers for any need. Our offerings include measuring from 10,000 amps to a few milliamps. This includes ANSI, Commercial, Ground Fault, High Frequency, Wound Primary, DC Immune and Nano Alloy current transformers.
-
Product
30A, 100MHz High Sensitivity Current Probe
CP031A
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Current Transformer Field Test Set
1043
-
The Catalog 1043 Current Transformer Field Test Set is a simple and inexpensive means whereby a current transformer installation may be quickly checked for many sources of trouble. The tests are made without interrupting the Customer's service and while the load is on.
-
Product
Current Sense Magnetics
-
Current sense magnetics are used as a low loss method for sensing AC current in a circuit and also provide electrical and safety isolation between the source of the current and the measurement circuit. The key parameters for a current sense transformer are the rms current rating (to ensure it does not overheat in the application) and the safety and voltage isolation (to ensure it conforms to the end-application requirements).
-
Product
2000 Amp DC / 1500 Amp AC Current Probe
DC2000
-
Our DC2000 Current Probe measures up to 2000 amps DC (as well as 1500 amps AC). Self-powered via our meter, so there are NO batteries that can run down during a measurement session.
-
Product
Current Measurements Of PWM Or Inverter, AC/DC 1~50A, Φ16mm
CTF-50DC-U24V
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 1~50A*Current measurements for PWM or inverter
-
Product
Contactless Torque Transducers
RS425
-
These contactless Torque Transducers are not limited by operational speeds, can fit any shaft and capable of measuring torque from 1nm and up to 500knm, providing highly accurate and reliable torque measurement in many applications.
-
Product
Sound Harmonics and Current Analyzer
H74050100
Audio Analyzer
This analyzer is used as end of line control for electro mechanic components with electric motors, with or without mechanical reduction. While the motor is running at nominal speed, a spectrum and temporal analysis of the sound as well as a current consumption test is performed. Statistical analysis of the data acquired is also performed real-time, expediting the PASS/FAIL decision of the DUT.
-
Product
Transducer Calibration
m+p SensCal
-
Regular transducer calibration is an essential requirement for maintaining the accuracy, reliability and repeatability of the results obtained from a measurement system. m+p international’s m+p SensCal program provides a quick and simple process for calibrating accelerometers (piezo-electric with charge output or IEPE, piezo-resistive, capacitive) in your laboratory, as well as velocity or displacement transducers.
-
Product
Current Transformer Tester
CT-T1
-
The CT-T1 is a microprocessor-based Current Transformer Tester that measures CT excitation current, turns ratio, and winding polarity tests, all without having to switch the leads during testing. The instrument has a fully automatic knee point detection (ASA 10/50, IEEE 30°, IEEE 45°). Although includes 5 low side taps and 1 high side tap.
-
Product
Suitable For Current Or Voltage Process Signals
SEM1600VI
-
The SEM1600VI is a “smart” powered isolator/conditioner that accepts any voltage signal between (-50 and 50) V dc or any current signal between (-50 and 50) mA
-
Product
SAFETY TESTERS ( CURRENT LEAKAGE TESTERS )
ST-05
-
Safety Tester Model ST-05 is a test set for testing small equipment powered by 120V 60 Hz, from an approved U-ground source. Test also can be run on double-insulated tools an on appliances with two-pin parallel plugs.
-
Product
Current Probes
-
PMI® introduces the convenience of flexible current probes (Flex CTs)! These 5,000A probes come in 12″, 24″, 36″, and 48″ lengths that allow you to easily surround multiple conductor bundles. They are available in sets of two, three, or four for use with different recorders. The Flex CTs are powered from recorder voltage and DO NOT require a battery pack for operation.
-
Product
AC and DC Non Inductive Current Shunt
Series A co-axial shunt and Option 02F/B shunt
-
Use with wattmeters, DMMs and power analyzers to extend current measurement ranges. Use with phase angle meters to enable phase angle measurements between voltage and current. Ultra low phase shift
-
Product
Portable Current Supply 10 AMP output
CS-10
-
The CS-10, Sure beats carrying around a rectifier and generator...
-
Product
Current Measurements Of PWM Or Inverter, AC/DC 10~200A, Φ24mm
CTF-200DC-U48V
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 10~200A*Current measurements for PWM or inverter
-
Product
Impulse Current Measuring Shunts
ICMS
-
The Impulse Current Measuring Shunts ICMS are new designed tubular shunt types with best response behavior to match the high performance of the TR-AS digital recorder for comparative current measurements. A 1st partial response time less than 10ns and a settling times less than 20ns show the advantage of these shunts. They show no initial overshoot peak, no oscillations and do not need compensation box to optimize the transient behavior as known from e.g. cage shunts.