Display Calibrators
reference a test pattern to adjust by.
-
Product
Electro Magnetic Flow Meter With Remote Display
MFI-013
-
Aarohi Embedded Systems Pvt. Ltd
MFI-013 electromagnetic flow meter is manufactured with state of the art technology. Micro controller based design provide precise measurement. A magnetic flow meter (mag meter, electromagnetic flow meter) is a transducer that measures fluid flow by the voltage induced across the liquid by its flow through a magnetic field.The physical principle at work is electromagnetic induction.
-
Product
Calibrator, Calibrated, Current, 185 mm, 78 mm, 38 mm, ± (0.25% FS +1 digit), ± (0.5%FS + 1 digit)
72-6694 CAL
-
The 72-6694 CAL from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
15.6" FHD Industrial Display Kit
IDK-1115W
-
15.6" LCD supports 1920 x 1080 resolution, LCD Brightness 450 cd/m2 with LED backlight, Projected Capacitive touch solution with Anti-Finger Print surface treatment.
-
Product
LCD Display Optical Measurement System
-
RayClouds Photoelectric Technology Co.,Ltd.
LCD display optical characteristics automatic measurement system is mainly used in LCD, LED screen, OLED screen, FPD, Mini LED, Micro LED and various new luminous materials.LCD display optical characteristic automatic measurement system supports the test of optical performance parameters such as viewing angle, luminance, uniformity, contrast, chrominance, response time, flicker, and refresh rate, etc.
-
Product
Decade Box, Calibrated W/D & U, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL DU
-
The 72-7265 CAL DU from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Portable Analyzer and Calibrator
-
ECD’s portable analyzer and calibrator product lines are a simple convenient way to obtain fast, accurate pH and ORP measurements. They provide a milliVolt output signal for fast field analysis of samples, calibration verification, or trouble-shooting of installed sensors.
-
Product
Power Calibrator And Protection Relay Test Set
CP11B
-
Calmet Smart Calibration Devices
Single phase, class 0.02 and 0.05 power quality calibrator up to 120A and 560VAC with programmable power quality parameters. It makes possible to make automatic test of electricity meters, measurement transducers, current transformers and protection relays.
-
Product
Acoustic Calibrators
-
When you're ready to take noise measurements, it's strongly recommended that you perform a field calibration using an Acoustic Calibrator. You should calibrate your sound meter before you start to measure, and then once you've finished you should perform a reference check against the calibrator and make note of any drift that has occured. You can find out more about performing Field Calibrators by reading this post and watching a short video.
-
Product
Calibration Services
-
Tempsens Calibration Centre is an independent unit of Tempsens instruments (I) Pvt. Ltd. We have calibration laboratories at Vadodara (Temperature Range for Contact Type Sensors -196 to 1600 deg C and for Non-Contact Type Sensors 50 to 1700 deg C) and Bangalore (Temperature Range for Contact Type Sensors -35 to 1600 deg C and for Non-Contact Type Sensors 50 to 1700 deg C).
-
Product
Color Calibration & Profiling
-
For both amateurs and professionals photographers, filmmakers, designers, premedia and printing operators achieving predictable results from capture to output can be a challenge. Color Perfectionists turn to X-Rite for affordable, professional, quality calibrating and profiling solutions that make sure all of your devices monitors, projectors, cameras, scanners, printers and mobile devices are speaking the same language.
-
Product
Calibration Kit
S2611
-
*S2611 Calibration Kit, * Frequency Range: up to 26.5 GHz, * Impedance: 50 Ohm, * Connector type: 3.5 mm female.
-
Product
Transducer Calibration
-
When it comes to finding the perfect transducer calibration system, look no further than MB Dynamics. Our Calibration Systems offer an extensive range, from the Win475-Basic, the trusted calibration solution for the United States Air Force; to the first of its kind Win475-TS, which measures a transducer’s transverse sensitivity. No matter what your needs, you’ll find the calibration equipment that works for you.
-
Product
Automatic Calibration Module
ACM4520
-
ACM4520 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 20 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process.
-
Product
Calibration & Demag.
Model 8515-D
-
The Model 8515-D is a medium-energy, high voltage, and capacitor discharge type ringing demagnetizer capable of desaturating Ceramic and Rare Earth magnetic materials. The Model 8515-D is easily adapted to a wide range of production and laboratory demagnetizing requirements. A modern solid-state electronic control circuit, coupled with a rugged, heavy-duty discharge SCR and fixture, make this demagnetizer a highly reliable, low maintenance unit. The electronic voltage control circuit prevents the Model 8515-D from being discharged before the preset energy level has been reached, avoiding incomplete magnet desaturation. An easy to read front panel meter monitors the capacitor voltage. The energy storage level can be easily changed in the field. Integral electrical interlock and fail-safe circuitry provide a high degree of operator safety.
-
Product
Automated Probe Calibration
AutoClock
-
Metrology Software Products Ltd
AutoClock is the first product in history which makes it possible to fully automate the probe calibration process. It provides fast, accurate and automated tool axis setting. It takes seconds to automatically set the tool axis offset to microns. This enables the probe to complete the automatic calibration process without human intervention.
-
Product
Horizontal Calibration Instruments (Lab)
THV
-
The horizontal THV instrument has been designed for calibration and certification of gauging equipment of small dimension. It allows easy and precise checking of plug gauges, ring gauges, thread plug gauges, test and dial indicators as well as measuring of high precision production parts.
-
Product
Calibration
-
General purpose calibration/diagnostic tool.Built in precision resistors.Simple manual contact/routing/resistor selection.4mm terminal posts on key device connections.In line mode to aid fixture wiring/DUT debugging.Comprehensive documentation including circuit schematics.Connecting cables.
-
Product
Standard Voltage 37 Pin D-Type Cables - Calibration Cables for Pickering
-
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 37-pin D-type calibration port connector.
-
Product
OTDR Training & Calibration Solution
-
In addition to network simulation applications, the Fiber Lab 800HE from M2 Optics is a professional optical fiber platform that enables technicians to practice using an OTDR to find splices, faults, or bad connections in a length of optical fiber. In addition to training, it can also be used by equipment servicing teams to calibrate OTDRs with fiber that includes pre-determined events at known points.
-
Product
15” XGA 1,200cd/m2 Ultra High Brightness Industrial Display Kit
IDK-2115
-
15” LCD supports 1024 x 768 pixels, Ultra-high brightness of 1200cd/m2 with external LED backlight, -20℃~+70℃ wide operating temperature support, High contrast ratio of 2500:1.
-
Product
Insulation & Multifunction Tester (LCD Display)
4153 IN
-
Standard Electric Works Co., Ltd
Microprocessor-controlled. Measures Insulation Resistance, voltage (AC-DC) measurements with automatic hold facility, diode, ohm, and continuity with a short circuit current of minimum 220mA. Auto-off function. Energy conservation feature. Ener-Save™ limit the test duration to about 10 Seconds. Quick Test and EnerSave™ are unique features. Both saves energy. No moving parts. All calibration are saved internally in a non volatile memory. Easy calibration at any facility around the world. Operates with rechargeable batteries, alkaline or low cost general purpose batteries. Low cost maintenance, calibration, and ownership. Complies to all the latest regulations, including UK.
-
Product
Phasor Measurement Unit Calibration System
6135A/PMUCAL
-
The 6135A/PMUCAL system is the only fully automated and traceable PMU calibration system available today. It fully complies to the IEEE C37.118.1™-2011 and section 7 of IEEE C37.242:2013 standards for PMU operation and verification.
-
Product
Broadband Horn Antenna (4GHz - 40GHz (calibrated from 18GHz))
PowerLOG® 40400
-
• Extremely wide frequency range from 4GHz to 40GHz (calibrated from 18GHz to 40GHz) • Supports high input levels up to 300W (peak) or 150W (CW) • High gain up to 17dBi • Delivered including specific calibration data • Perfect for EMC and immunity tests with Spectrum Analyzer.
-
Product
Current Probe Calibration Fixtures
-
Calibration fixtures are used for calibration of Coupling Loss/Transfer Impedance of current probes and BCI probes, as well as for the calibration of test levels for conducted immunity/susceptibility tests using BCI probes.
-
Product
2", 4", 6", 8" or 11" Large-Digit Displays
Grand Series
-
Available with 57 mm (2.2"), 102 mm (4.0"), 144 mm (5.7"), 200 mm (7.9"), or 280 mm (11.0") digit height for clock, timer, totalizer, frequency and rate inputs. RS-422 and dual-relay output options.
-
Product
Hand Calibrators
-
Portable, highly accurate electronic test tools used to measure, simulate, and calibrate electrical signals and temperature sensors in industrial and laboratory settings.
-
Product
Surface Display Unit
Multigauge 3100
-
Used with the Multigauge 3000 to provide displayed measurements on the surface. Two way communication to the Multigauge 3000. Ideal for class surveys or when visibility is poor.
-
Product
Automatic Calibration Module
ACM2509
-
ACM2509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full two-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to seven connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.





























