Phantom Loads
generate different current values based upon the current rating of the energy meter under test. 2) standby power of a device turned off.
See Also: Parasitic Drain
-
Product
High Current Electronic Load (600W-1200W)
ELCH600 & ELCH1200
-
- Low lead resistance <5m Ohm for Fuel-cell- Battery Testing- VFD display- High resolution 0.1mA/1mV- Voltage range 0V to 500V- Working mode CV/CC/CW/CR- OV/OC/OP/OT protection- Communication: USB/RS232/GPIB
-
Product
LOADpro Load Testers
-
LoadPro is an external Web load testing service. A LoadPro test simulates actual user traffic from outside your network, stressing your entire infrastructure in order to discover bottlenecks that impact performance under peak traffic.
-
Product
Hand-Held/Digital Load Tester
6030DV
-
• Full 125 Amp load Tests 12 Volt and 24 Volt batteries (DUAL LOAD) alternators and starters on all types of vehicles• PATENTED• Made in USA of US and Global Components
-
Product
Structural Load Monitoring
SLM
-
Since 2001 ITM has installed structural strain based monitoring systems in the pulp & paper and energy generation industries. For these systems, our engineers and field service technicians turn structures into measurement instruments (load cells). Load outputs from the structural load cells are monitored and published by a realtime controller to its local interface or network historians and HMIs.
-
Product
JD Edwards Load Testing
Dimension LoadTest
-
Dimension LoadTest™ is a powerful yet easy to use load testing tool for JD Edwards EnterpriseOne applications. DWS have designed Dimension LoadTest such that any experienced System Administrator/CNC should be able to setup, create, run and monitor load tests to effectively stress test JD Edwards EnterpriseOne applications.
-
Product
DC Electronic Load
EE30140A
-
The EE30140A DC Electronic Load / Works @ 0.0 Volts Input & real time I/O control. attach the electronic load block to a heat- sink and your up and running used them with D to A's, A to D's, Pots, PLC's to control the current. These Electronic Loads can be used for both Discharge & Charging Batteries & Devices
-
Product
Miniature S-Beam Load Cell
500 Series
-
The Miniature S-Beam Load Cell is a bi-directional Aluminium strain gage based transducer with high performance and builtin temperature compensation. This design provides better than ±0.1% (full scale) non-linearity and includes overload protection in both tension and compression directions. Options include IEEE1451.4 TEDS capability.
-
Product
LED Test Programmable DC Electronic Load
IT8912E Series
-
IT8900 series high accuracy LED specific testing electronic loads can simulate the real output of LED lights with different characteristics.Their specific circuit can realize CR-LED mode, adjustable frequency, duty ratio PWM dimming output port (frequency: 20Hz-2KHz), I-pp/I-max measurement function can test current ripple and start up surge current of LED constant flow source. Voltage and current testing speed can reach 50KHz. IT8900 series provides CR-LED / CC / CV + CC / CR /CW and other working modes, built-in USB / RS232 / GPIB communication interface. Widely used in LED driver power dimming test.
-
Product
Large Compressive Load Cell
CCLG-3.0
-
DLM’s range of Large Compressive load cells can be used independently or in combination as part of weighing platforms.
-
Product
Bottle Vertical Load Testers
-
Bottle Vertical Load Tester measures the vertical load strength of glass containers, simulating capping and stacking loads.
-
Product
Load Pull Test Fixtures
-
Low Insertion Loss for High VSWR TuningMultiple Connector Configurations50Ω and Transformers (Klopfenstein, Quarter-wave) AvailableHeatsinks and Fans AvailableCooling (Water cooling, Forced air cooling) AvailableIntegrated Biasing Available
-
Product
Heavy Load Ball Screw with Caged Ball Structur
HBN
-
Heavy Load Ball Screw with Caged Ball Structure. Heavy load ball screws with the caged ball structure (HBN model) drastically improve the rated load compared to the conventional products by utilizing the optimum internal structure for use in heavy load condition. In this model, the caged ball structure is adopted between balls to eliminate collisions and mutual frictions of the balls and improve the lubricant maintenance. This modification brings about a longer lifetime under heavy load conditions.
-
Product
Battery Load Bank
-
Foresight Electronics Co., Ltd.
Utility is used for battery systems range from 21-30V, if higher current is needed, two or more FST-24V units can be linked together. Discharge to Battery string voltage as 24V, Cell voltage as 1.2V/2V/6V/12V adjustable stop points and multiple alarm designs to control the discharge process intelligently 7inch LCD touch screen for easy operation and showing various parameters real time Support RS232 real time monitoring by PC or SD Card download data after discharge
-
Product
cPCI Load Boards
-
VECTOR Electronics and Technology, Inc.
Vector Electronics & Technology, Inc. cPCI resistive load boards provide a means to test power generated and cooling capability of cPCI systems.
-
Product
Battery Extra Load Units
BXL Series
-
BXL is an extra load unit designed to be used with DV Power’s BLU series battery testers. However, this unit is a universal add-on device. Because of that, it is compatible, as an additional load, with any other discharge/capacity tester in the market.In case when discharge current exceeds the capacity of a single BLU device, BXL can increase the discharge capacity. There are no limitations on the number of extra load units that can be connected in parallel to the main battery tester.A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way. Also, all instruments are in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.These units can be used on any type of battery string, such as lead-acid, Li-Ion, Ni-Cd, etc. They test battery strings with voltages in the range of 5,25 – 500 V DC. On the other hand, current up to 250 A can be discharged through the BXL internal structure.The instrument simulates a constant resistance load during the discharge test. Several resistances can be set for different battery nominal voltage levels. This makes BXL extremely flexible in selecting its load capabilities.
-
Product
Phantom Vent Tube Metal Detector
-
The Phantom Vent Tube metal detector is primarily designed to detect and track a fallen vent tube nozzle inside a bottle that is conveyed through bottle-processing equipment. The convenient retrofit design allows for easy installation into existing bottling lines. Built from stainless steel (304) material and totally enclosed for washdown purposes, the detector phases out the conveyor belt and maintains a steady sensitivity.
-
Product
130 AMP Battery Load Tester
MD4370
-
Compact, ergonomically designed tester determines a battery's charge and tests batteries, starting, and charging systems.Powerful 130 amp load capacity provides more accurate test results.Uniquely designed clamps assure a positive connection on any style battery.
-
Product
Load Testing
-
Load Testing, Simplified. We sort out the infrastructure, so you can spend more time testing. Tool Agnostic - We support JMeter, Gatling, Capybara and Selenium. Unfettered Testing - No limits on how you test, run as many users for as many tests, for as long as you like. Third-party Integration - Send results to Slack, Hipchat, Flowdock, or your own services using our API.
-
Product
Thermal Load Boards
-
Thermal Engineering Associates, Inc.
A Thermal Load Board (TLB) is used to simulate an application printed circuit assembly (PCA) either before all the heat-producing components are available for mounting on the application PCA or if the heat-producing components require complex electronic circuitry to create heat within the components. The TLB is typically designed to be as mechanically and thermally equivalent to the application PCA and usually offers a way to vary the power dissipation of the elements that simulate the heat-producing components.
-
Product
LED Load Simulator
63110A/ 63113A/63115A
Simulator
As shown on the V-I curve in figure 1, the LED has a forward voltage VF and a operating resistance (Rd). When using a resistor as loading, the V-I curve of the resistor is not able to simulate the V-I curve of the LED as shown in blue on figure 1. This may cause the LED driver to not start up due to the difference in V-I characteristic between the resistors and the LEDs. When using Electronic Loads, the CR and CV mode settings are set for when the LED is under stable operation and therefore, is unable to simulate turn on or PWM brightness control characteristics. This may cause the LED driver to function improperly or trigger it’s protection circuits. These testing requirements can be achieved when using a LEDs as a load; however, issues regarding the LED aging as well as different LED drivers may require different types of LEDs or a number of LEDs. This makes it inconvenient for mass production testing.
-
Product
Load Cells for Weighing
-
HBM provides the optimal Load Cell or Load Sensor for your application. Beam Load Cells: The All-Rounders For Weighing Technology. Ring-Torsion Load Cells: Low Profile And Powerful. Canister Load Cells: Maximum Capacities Up To 400 t. Single Point Load Cells: The Standard in Scales Manufacturing. Digital Load Cells: Ideal For Dynamic Weighing. Weighing Modules: Pre-assembled For Tank And Silo Weighing.
-
Product
Medium Capacity Single Point Bending Beam Load Cells
SPL SERIES
-
The SPL Series single point load cell simplifies scale designs, packaging machinery and other industrial weighing equipment. Their single point design eliminates the need for multiple load cells and summing boxes, and thus, simplifies the design and reduces the cost. All SPL Series load cells employ 100% aluminum construction and features a moisture proof sealant which also makes them suitable for damp environments.
-
Product
Digital Panel Mount Load Cell Meter
MODEL DPM-3
-
The DPM-3 is a smart Plug & Play TEDS IEEE 1451.4 compliant Digital Panel Mount Load Cell meter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the DPM-3 will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the DPM-3 can be set up by simple front panel push buttons. The DPM-3 can be scaled to a full 5 digit display from 0 to 99,999 counts to read directly in engineering units such as grams, ounces, pounds, etc. The DPM-3 samples 60 readings per second (50 for 50Hz operation) for fast control response and true peak/valley reading capability. The meter has an adaptive digital filter that can automatically select the best time constant for minimum noise, yet respond rapidly to an actual change in signal level. The peak and valley values can be displayed by a push of a button on the front panel. Auto-tare allows the meter to be set to zero for any input signal level. Available options include dual relays, analog output, serial communications, and low voltage power supply.
-
Product
AC Load Simulating Inductors
-
Osborne designs our AC Inductors to provide the desired inductance and to perform effectively with the dissipation characteristics presented to the circuit. Dissipation characteristics depend on circuit current and operating frequency. The Osborne design approach is unique to the extent that we design for frequency effects. The resulting inductors deliver superior performance.
-
Product
Load Cell Power Supply Module
MODEL PSM-F10
-
The PSM-F10 is a chassis mountable power supply package. They are ideal for use with dedicated microprocessor systems, instrument design and test equipment. The PSM-F10 can also be used as a supplemental bench or laboratory power supply. The special "Cclamp" type barrier strip secures the wire without twisting. Note the protected recessed barrier strip facing the top of the case. This allows connections to be made in tight areas while protecting the barrier strip from physical damage. Nothing else offers this combination of ruggedness, flexibility and convenience.
-
Product
Load Termination
-
A process of ending a transmission line or cable to either dissipate energy as heat or prepare it for connection to a device.
-
Product
Low Capacity Single Point Bending Beam Load Cells
LSP SERIES
-
The LSP Series is a low capacity, low cost, high accurate single point bending beam load cell. It is ideal for OEM applications such as electronic scales and weighing machines. The single point design is highly resistant to eccentric loading allowing direct mounting to the scale base and weighing platform. The LSP Series features a moisture proof sealant.
-
Product
Battery Load Banks
-
Kongter Test & Measurement Co., Limited
Kongter offers many different models of battery load units for real capacity test in various industries. With our customized solution, users of different applications will find their exact models as per their needs. With its optional DAC (Data Acquisition Case), you could easily monitor voltage of each cell on PC during battery discharge test.