2-wire
resistance measurement method.
-
Product
TB-2636, Screw Terminal, 4x32, 2-Wire PXI Module Matrix Terminal Block
196762-01
Terminal Block
The TB-2636 provides the necessary routing to configure the PXI-2529 PXI Matrix Switch Module as a 2-wire 4×32 matrix. You can directly connect the TB-2636 to the front panel I/O connectors of the PXI-2529. The TB-2636 includes screw terminals that provide access to the rows and columns of the matrix.
-
Product
PXI High-Density Multiplexer: 64-ch, 2-Wire, 100Vrms/1A, Reed Relays
M9101A
Multiplexer Module
The M9101A, a high-density, 64-channel PXI multiplexer routes many different channels to a single point. The switches operate in a break-before-make mode that ensures no two points are connected at the same time or, if needed multiple channels can connect simultaneously. Ideal for routing multiple analog signals to a measurement device in automated test environment (ATE) or data acquisition systems. Each channel switches a high and a low for 2-wire switching up to 100Vrms, with up to 10W of power. Connection options include the durable connector block or the standard cable connections.
-
Product
SWB-2813, 4x21, 1 A, 2-Wire Reed Matrix Module for SwitchBlock
781420-13
Matrix Switch Module
4x21, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2813 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
Product
PXI High Density Multiplexer: 99-ch, 2-Wire, 100Vrms/1A, Armature Relays
M9103A
Multiplexer Module
The M9103A, a high-density, high-power 99-channel multiplexer routes many different channels to a single point. The switches operate in a break-before-make mode that ensures no two points are connected at the same time, or multiple channels can simultaneously connect if needed. This module is ideal for routing multiple analog signals to a measurement device in an automated test environment (ATE) or data acquisition systems. Each channel switch has a high and low for 2-wire switching. The high-quality armature relays are capable of switching up to 100Vrms, with up to 60W of power. Choose from the durable connector block or standard cable connections.
-
Product
PXIe-2739 , 256-Crosspoint, 16x16, 2-Wire PXI Matrix Switch Module
782835-39
Matrix Switch Module
256-Crosspoint, 2-Wire PXI Matrix Switch Module—The PXIe‑2739 is a high‐density 16x16 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.
-
Product
Banana-Triax Adapter For 2‑Wire (Non-Kelvin) Connection
N1297A
-
The N1297 Series is a collection of banana-triax adapters for the Keysight B2900 Series precision source measure unit (SMU). It consists of both 2-wire as well as 4-wire connection requirements.
-
Product
PXI-2529, 128-Crosspoint, 2-Wire PXI Matrix Switch Module
778739-01
Matrix Switch Module
The PXI‑2529 is a high‐density PXI matrix switch module that you can configure as either a 4x32 or 8x16 2‑wire matrix by using different terminal block accessories. It uses electromechanical relays that offer excellent performance for high-power signals and low thermal offset for accurate measurements at low-voltage levels. The PXI‑2529 also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
Product
PXI-2576, 64‐Channel, 2-Wire, Multibank PXI Multiplexer Switch Module
778572-76
Multiplexer Module
64‐Channel, 2-Wire, Multibank PXI Multiplexer Switch Module —The PXI‑2576 is a multibank PXI multiplexer switch module with 16 banks of 4x1 2‑wire multiplexers. With the flexible architecture of the PXI‐2576, you can configure it in a variety of topologies that make it suitable for parallel measurement operations requiring low‐channel counts, or you can combine all multiplexer banks to form a single high‐channel‐count multiplexer featuring 64 2‑wire channels. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
Product
SWB-2814, 8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock
781420-14
Matrix Switch Module
8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2814 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
Product
SWB-2814, 8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock
781421-14
Matrix Switch Module
8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2814 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
Product
NI TB-2645B Terminal Block for NI 2532B as 1-Wire Dual 16x16 Matrix or 2-Wire 16×16 Matrix topology With Column Protection Resistors
782385-12
Terminal Block
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
VXI 16-Channel, 2-Wire LVDT/RVDT Simulation
65DL1
Simulator
NAI’s 65DL1 is a 16-channel, 2-wire, LVDT/RVDT Simulation Instrument on a VXI board. This single-slot, message-based board provides 16 independent, transformer-isolated, LVDT/RVDT, programmable 2-wire outputs (up to 34 V), wrap-around self-test, and an onboard programmable excitation supply.
-
Product
Isolated RS-485
-
Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications. The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus.
-
Product
Legacy Liquid Detection Rope Sensor
ENVIROMUX-LDSx-y
-
For warning of flooding. Detects liquid depth >0.1" (2.5 mm). Minimum puddle: 0.6" (15 mm) diameter. 100% waterproof electronics. Detects any liquid or moisture, except deionized water. RJ45 connector. Voltage Supply: 12VDC. Current Consumption: 20mA. Supports CAT5/5e/6 cable up to 1,000 ft. (305 m). Available water sensor cable (x) lengths: 1/10/50/100/200/400/600/800/1000 feet. Plenum rating: CL2P (UL). Available 2-wire cable (y) lengths: 5/10/20/50/100 feet. Powered by ENVIROMUX-SEMS-16U and SERIMUX-S-x. Regulatory approvals: CE, RoHS. Requires the ENVIROMUX-SEMS-16U and SERIMUX-S-x to operate. Use self-adhesive clips (ENVIROMUX-CLP10-LD) to prevent sensor rope cable from shifing after installation. ENVIROMUX-CLP10-LD includes 10 clips.
-
Product
Micro-Ohmmeter
3207
-
The Ballantine 4 Digit Micro-ohm Meter 3207 measures Low Resistance in Milli and micro-ohms with precise accuracy. It employs the proven 4-wire measurement technique and eliminates the lead resistance inherent in 2-wire technique to give accurate readings.
-
Product
NI TB-2646B Terminal Block for NI 2532B as 1-Wire Quad 4x32 or 2-Wire Dual 4×32 Matrix Matrix Topology Without Column Protection Resistors
782385-13
Terminal Block
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
Switch Mainframe
SW1002
-
Switch between voltmeter and battery tester while testing. 264 channels max. (2-wire) to 72 channels max. (4-terminal pair). Circuit design friendly for impedance measurements that minimize errors between channels (Effect: 0.01% f.s.*). For BT4560 100 mΩ range, R measurements, and a measurement frequency of 1 kHz. For OCV measurement, internal resistance measurement, and external potential measurement of battery cells. Measure battery modules up to 60 V DC.
-
Product
LVDT Signal Conditioner
NTC-6000
-
Quick and easy setup with front panel push buttons and LED indicatorsSelectable excitation frequency, analog outputs and bandwidthAutomatic excitation synchronization for multiple unit systemsSelf-diagnostics for LVDT failure, disconnect, or short circuitDigital communications via RS-485 2-wire multi-drop busHot swapability — setup can be saved and reloaded via RS-485 portCybersecurity lockout and tamper detectWorks with nearly any AC LVDT, RVDT, or LVRT half bridge
-
Product
Digital Power Recorder
MPR-601W-01
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Applicable for single phase 2wires and single phase 3wires and *3phase 3wires and 3phase 4wires system*Wide measuring range up to 0~500V/500A*Easy data logging by USB flash memory
-
Product
Weather Resistant Surge Protector for RS485 Control & 12VDC Power Lines
SP-RS485-12V-O
-
Ideal for applications such as video surveillance cameras and access control. Protects sensors running on 22 AWG 2-wire sensor cables or 12VDC power lines against the effects of electrostatic discharge, faulty wiring and lightning. RS485 protection: Stage 1 clamping voltage: ±90V; Stage 2 resistance: 3.3 Ohms; Stage 3 clamping voltage: ±7.5V. 12VDC power lines protection: Stage 1 clamping voltage: ±90V; Stage 2 current rating: 3A; Stage 3: 12V TVS (transient voltage suppression) diode. Screw terminal pairs for RS485 and 12VDC power lines protection. Will also protect two single ended data, analog or control lines. Impact and weather resistant enclosure with locking hinged cover.
-
Product
NI TB-2641B Terminal Block for NI 2532B as 1-Wire 8x64 Matrix Topology Without Column Protection Resistors
782385-03
Terminal Block
The TB-2641B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x128 matrix. You can directly connect the TB-2641B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2641B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
PXIe-2737, 256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module
782835-37
Matrix Switch Module
256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module—The PXIe‑2737 is a high‐density 4x64 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.
-
Product
Keysight Dual/Quad 4x8 Reed Matrix for 34980A
34933A
Matrix Switch Module
The Keysight 34933A module for the 34980A Multifunction Switch/Measure Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. Dual 4x8, 8x8, or 4x16 2-wire configurations 64 2-wire or 128 1-wire cross-points High-speed reed relays Connections to the internal DMM Expandable via four 2-wire analog buses Relay counter ±150 V peak, .5 A switch, 1.5 A carry current
-
Product
NI TB-2645B Terminal Block for NI 2532B as 1-Wire Dual 16x16 Matrix or 2-Wire 16×16 Matrix Topology Without Column Protection Resistors
782385-11
Terminal Block
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
LVDT/RVDT Simulation Board
75DL1
Simulator
The 75DL1 is a cPCI LVDT/RVDT Simulation Board that provides eight 2-wire or four 4-wire transformer isolated programmable outputs. It provides wrap-around self-test, PXI compatibility, optional Excitation Supply, and is available for Military or Commercial applications.
-
Product
PXI Serial Interface Module
Serial Interface
The PXI Serial Interface Module offers a number of options for connecting to serial hardware. You can choose from common serial protocols, such as RS232, RS422, and RS485. The PXI Serial Interface Module also offers various isolation, hyperthreading, and multiprocessor compatibility options as well as 4- and 2-wire transceiver modes for full- and half-duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
Product
External Temperature for PT100 Probe
TGP-4104
-
This data logger uses an external PT100 probe to record high temperatures. Probes are available to measure up to 300 and 600C. These are listed in the 'You will also need' section. The PT100 probes are of 3-wire construction and use class A elements, making them more accurate than their 2-wire predecessors.
-
Product
Speed Sensors Dust Ignition-Proof
ST420-LT / ST420-DI
-
Features • 2-wire, loop-powered 4-20 mA analog output • No user calibration – works right out of the box • Standard and custom measurement ranges available • Reverse-wiring protected Rugged stainless steel M18x1 housing with integral conduit attachment; FM approved, dust ignition-proof. Class II, Div I (E, F, G); NEMA 4X, IP65
-
Product
Cable and Harness Tester
CHT
-
The Cable and Harness Tester (CHT) provides multiple testing capabilities for up to 300 connector/harness test points. Test capabilities include DC Insulation Resistance (IR), DC and AC Dielectric Withstanding Voltage (DWV), and 2-Wire and 4-Wire Continuity.
-
Product
Interface
RAR-PCIE
Interface
Available in a range of configurations to match your needs, RAR-PCIE provides complete, integrated databus functionality for ARINC 429, ARINC 575 and selected 2-wire, 32-bit protocols.





























