Showing results: 106 - 120 of 439 items found.
-
ІТ-09Т -
Ecotest
Display of measurement results of ambient dose equivalent rate(DER) of gamma radiation obtained from the BDBG-09 detecting unit of gamma radiation;Real time display;Air temperature display;Audio and light alarm when threshold levels of gamma radiation DER exceeded.
-
MRC ltd.
The preferred method of infrared spectroscopy. When IR radiation is passed through a sample, some radiation is absorbed by the sample and some passes through (is transmitted).
-
Electronic Specialties Inc.
An infrared thermometer is a thermometer which infers temperature from a portion of the thermal radiation sometimes called black-body radiation emitted by the object being measured.
-
-
Atomtex
Control of X-ray and gamma radiation personal dose equivalent.The dosimeter together with the PC reader and the software forms an efficient automatic system for staff radiation exposure control.
-
-
LPPYRA10… Series -
Delta OHM S.r.L.
The pyranometers LPPYRA10 measure the irradiance on a flat surface (Watt/m²). Range 0-2000W/m² or 0-4000W/m². The radiation measured is the sum of direct solar irradiance and diffuse irradiance (global radiation).
-
SPECTRA Pro -
Ametek Power Instruments
The SPECTRA PRO's frequency discrimination feature allows it to filter out background radiation from hot, glowing boiler walls and also radiation interference from neighboring burners or pilots. This discrimination capability ensures that when a flame is extinguished, the relay trips immediately because there are no background radiation effects that could provide a false flame on condition.
-
Hukseflux Thermal Sensors B.V.
SRA01 albedometer is an instrument that measures the solar albedo, or solar reflectance, and net solar radiation. It is composed of two second class pyranometers with thermopile sensors, the upper one measuring global radiation, the lower one measuring reflected solar radiation. It complies with the latest ISO and WMO standards. SRA01 can be connected directly to commonly used datalogging systems.
-
Lisun Electronics Inc.
Photobiological Safety of Lamps and Lamp System and IEC TR62471-2(2009) Guidance on Manufacturing Requirements Relating to Non-laser Optical Radiation Safety have be published addressing hazard to human (mostly eye and skin), and are completely suitable to assess the optical radiation safety of non-laser sources, such as LED products, UV radiation in general lighting products and etc.
-
Renesas Electronics Corp.
Renesas' radiation hardened linear regulators (LDOs) are optimized for fast transient response and single event effects (SEE). These LDOs are designed to provide highly reliable performance in harsh radiation environments.
-
PCE Instruments
A geiger counter detects nuclear radiation by measuring the emission of ionizing radiation of alpha particles, beta particles and gamma rays. Also referred to as a radiation detector, a geiger counter consists of two main elements: the processing electronics and the geiger tube. The geiger tube is filled with low-pressure inert gas like helium, argon or neon. If radioactive radiation occurs, the inert gas is ionized. An anode within the geiger tube registers the quantity of ionized particles numerically correlating with the strength of the radioactive radiation. The radioactivity measurement is then displayed on the LCD screen of the geiger counter or radiation detector.It is very important to measure radioactivity as well as to classify radioactivity values. For example, terrestrial gamma radiation is measured according to general values from 0.03 - 0.3 µSv/h (microsievert / hour). This "normal" oscillation range is conditioned by natural radioactive elements in the ground such as uranium and potassium. To calculate this factor, one must take into consideration cosmic radiation. For example, when considering cosmic radiation, the maximum radioactivity content at Schneefernerhaus, the highest-located German environmental research station, is approximately equal to 110 µSv/h.At PCE Instruments, you will find three types of geiger counter or raditation detection devices to help you measure radioactivity: 1) alpha radioactivity meters, 2) meters for detecting alpha, beta and gamma radioactivity and 3) radioactivity meters for human beings.
-
CMP 21 -
Kipp & Zonen B.V.
The CMP 21 pyranometer is designed for measuring the irradiance (radiant flux, Watt/m) on a plane surface, which results from the direct solar radiation and from the diffuse radiation incident from the hemisphere above.
-
MKS-05 Terra -
Ecotest
Measurement of gamma and X-ray radiation ambient dose equivalent rate.Measurement of gamma and X-ray radiation ambient dose equivalent.Measurement of surface beta-particles flux density.Measurement of dose equivalent accumulation time.Real time measurement (clock).
-
IR-762 -
Infrared Systems Development Corp.
The IR-762 Energy Modulator is a variable speed rotating disk chopper designed for use with radiation sources, including blackbody, tungsten filament, mercury lamps, Nernst glowers and as part of instruments where modulated radiation is needed.