Multiplexers
Combine multiple signals into one signal.
See Also: Switching, Switching Matrix, High Voltage Switching, Switching Matrices, General Purpose Switch
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 18 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-785C-523-TE
-
The 40-785C-523-TE (PXI) and 42-785C-523-TE (PXIe) are triple failsafe SP6T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 10-Bank 6GHz SMA
60-801-010
-
The 60-801-010 is a 6-channel, 10-bank RF multiplexer suitable for switching 50Ω signals up to 6GHz. It is part of a range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for between 1 and 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI-2548, 2.7 GHz, 50 Ω, Quad SPDT PXI RF Relay Module
778572-48
-
2.7 GHz, 50 Ω, Quad SPDT PXI RF Relay Module - The PXI‑2548 is a general-purpose single‑pole double‑throw (SPDT) switch module. You can use it to add flexibility to your switch network or to maintain uniform signal paths across multiple channels when building high-channel-count multiplexers. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use its onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
Product
PXI Dual SP6T Multiplexer 6GHz 50 SMA
40-784A-002
-
Pickering Interfaces' range of 40-784A PXI Microwave Multiplexer Modules have a characteristic impedance of 50 and are capable of switching signalsup to 40GHz. Available in single, dual or triple, SP6T or SP4T formats, they are suitable for constructing complex microwaveswitching networks and provide a range of switching configurations to suit most applications. Connection is by high performancefront panel mounted SMA or SMA-2.9 connectors
-
Product
PXI 3A Power MUX BRIC, 3-Channel, 48-Pole
40-571-003
-
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
Product
PXI/PXIe MIL-STD-1553 Multiplexer, Single 8-Channel, 2-Pole
40-739-003
-
The 40-739-003 (PXI) and 42-739-003 (PXIe) are single 8-channel 2-pole multiplexers designed specifically for physical layer multiplexing or demultiplexing differential signals that conform to the MIL-STD-1553 specification. The module can be supplied as a single or dual 16-channel 2-pole multiplexer with each signal pair having a controlled 78 Ohm differential impedance.
-
Product
PXI 2A Multiplexer, 1-Bank, 64-Channel, 2-Pole
40-614C-016
-
This 1-bank, 64-channel, 2 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 4-Bank 6GHz SMA
60-801-004
-
The 60-801-004 is a 6-channel, 4-bank RF multiplexer suitable for switching 50Ω signals up to 6GHz. It is part of a range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for between 1 and 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI High Density Multiplexer, 47-Channel, 2-Pole
40-640A-022-47/2
-
The 40-640A-022-47/2 is a 47-channel, 2-pole MUX and is part of a series of high density multiplexer modules featuring a choice of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI Single 2 x 2 Fibre Optic (M Mode) ST M50
40-860-512-M50
-
Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.
-
Product
LXI Microwave Multiplexer, SP6T, 13-Bank, 18GHz, 50Ω, SMA
60-800-113
-
Our 60-800-113 is a 13 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 18GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP4T, 18 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-785C-421-TE
-
The 40-785C-421-TE (PXI) and 42-785C-421-TE (PXIe) are single failsafe SP4T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI Dual 2 x 2 Fibre Optic (M Mode) STM62.5
40-860-522-M62.5
-
Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 50 GHz, 50 Ω, SMA-2.4, Remote Mount, Failsafe
42-785C-553-E
-
The 40-785C-553-E (PXI) and 42-785C-553-E (PXIe) are triple failsafe SP6T 50 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI Source Switching Module
40-618-001
-
The 40-618 PXI Source Switching Module consists of 12 separate 4-channel multiplexers and 44 uncommitted SPST relay contacts in a single width PXI module. Typical applications include signal routing for avionics test systems that conform to the ARINC 608A specification.
-
Product
PXI 4 Banks Of 20 Chan Screened 1 Pole MUX
40-615-021-S-4/20/1
-
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI/PXIe MEMS RF Multiplexer, Single 4-Channel, 4GHz, 50Ω, SMB
42-878-211
-
The module is based on the latest micro-electromechanical system (MEMS) switching technology and has low insertion loss and VSWR. In addition, MEMS devices have a long operational life of >3 billion operations and benefit from an operating time of <20 μs allowing greater test system throughput. The multiplexers have excellent and repeatable RF characteristics beyond 4 GHz with each path having a nominally equal insertion loss.
-
Product
PXI Single SP4T MUX 6GHz 50Ω SMA
40-784-101
-
Pickering Interfaces’ 40-784 PXI Microwave Multiplexer Modules have a characteristic impedance of 50 Ohm and are capable of switching signals up to 40GHz. Available in single or dual SP6T or SP4T formats, they are suitable for constructing complex microwave switching networks and provide a range of switching configurations to suit most applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
16-bank, 4-channel, 2 pole version is part of the 40-614C High Density 2A Multiplexer
40-614C-002
-
This 16-bank, 4-channel, 2 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI Very High Density Multiplexer, 198-Channel, 1-Pole
40-675A-002-198/1
-
The 40-675A-002-198/1 is a 198-channel, 1-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
Product
LXI Microwave Multiplexer, SP6T, 5-Bank, 18GHz, 50Ω, SMA
60-800-105
-
Our 60-800-105 is a 5 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 18GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
LXI Microwave Multiplexer, 50Ω 4-Channel 15-Bank 18GHz SMA
60-802-215
-
The 60-802-215 is a 4-channel, 15-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
LXI High Voltage Switching - 8-Bank, 1-Pole, 6:1 Multiplexer Plugin Module
65-231-712-HI
-
The 65-231-712-HI plug-in module is part of a scalable high voltage multiplexer platform that provides a high voltage switching solution with capability up to 7 kV. Multiplexers are created by populating the 65-200-002 scalable chassis with multiplexer plug-in modules that provide access to the Channel and Common signals on 51-pin front panel connectors.
-
Product
PXI 3A Power MUX BRIC, 15-Channel, 16-Pole
40-571-205
-
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP8T, 40 GHz, 50 Ω, SMA 2.9, Terminated, Remote Mount
40-788-051-TE
-
The 40-788-051-TE (PXI) and 42-788-051-TE (PXIe) are single SP8T 40 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays.
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Single 12-Channel, 2-Pole
40-514-105
-
The 40-514-105 (PXI) and 42-514-105 (PXIe) are low density multiplexers in single 12-channel, 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
LXI Microwave Multiplexer, SP6T, 11-Bank, 18GHz, 50Ω, SMA
60-800-111
-
Our 60-800-111 is a 11 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 18GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI 8-slot BRIC Power Multiplexer, 9-Channel, 16-Pole (5 Sub-cards)
40-571A-203
-
The 40-571A-203 is a 9-channel, 16-pole 3 Amp Power Multiplexer and is part of our BRIC family. The 40-571A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
Product
Synchro to Digital-Resolver to Digital Converters
MSI MRI MX
-
Computer Conversions Corporation
Computer Conversions MX Series are low cost multiplexed synchro or resolver to digital converter sets designed for Military or Industrial diagnostic and control applicatioms requiring 3-128 axis per control.
-
Product
PXI 8x SPST High Voltage Reed Relays
40-310-001
-
The 40-310/320 range of high voltage switching modules will hot switch up to 750V peak and cold switch up to 1000V peak in either general purpose relay (40-310) or multiplexer (40-320) configurations. These modules contain high-quality reed relays with switching ratings comfortably higher than the 40-310/320 specification. Applications include; circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.




























