  • Test & Measurement Products

    Cole-Parmer Instrument

    We offer a broad range of test and measurement devices for your scientific, educational, industrial, and process applications. We carry the test and measurements tools you need to analyze, validate, and verify measurements in your electronic and mechanical systems, ensuring compliance to quality assurance and quality control programs. Our selection features portable and bench oscilloscopes, multimeters (DMMs), clamp meters, megohmmeters, stroboscopes and tachometers, power transformers, along with precision meters for humidity, moisture, light, airflow, weather, and vibration.

  • Resonance Dip Meter

    NRM-2 - National RF, Inc

    National RF’s Resonance Dip Meter is a test instrument used to determine the resonant frequency of a tuned circuit or resonant network, such as an antenna system. In addition, the unit may function as an RF detector, or a secondary frequency source. The instrument is analogous to the older vacuum tube “grid dip meter,” once popular in every electronic laboratory or radio station. Unique to this updated version is a buffered output that may drive a digital frequency counter for exact measurement of resonant frequency, or connected to an oscilloscope to be used as an RF detector and waveform/modulation monitor.

  • 2.92mm to ProBus Probe Adapter

    L2.92A-PBUS - Teledyne LeCroy

    The Teledyne LeCroy LabMaster 10 Zi oscilloscope utilizes precision 2.92mm input connectors to achieve up to 36GHz of input bandwidth. But some applications may require the use of lower-bandwidth probes for performance and cost reasons.The L2.92A-PBUS adapter converts the 2.92mm interface to a ProBus interface. This brings the benefits of a wider selection of probes to the LabMaster 10 Zi from high-impedance ZS active probes to the high-bandwidth WaveLink differential probing system. Full probe power and control is provided through a built-in LEMO interface.

  • Optical Modulation Analyzer

    OMA - Quantifi Photonics Inc.

    In partnership with Tektronix, we bring you a high-performing and flexible OMA system that will meet your requirements today and into the future.With the market-leading performance of Quantifi Photonics’ IQRX coherent receiver and the scalable architecture of Tektronix’s high-performing oscilloscopes, you’ll get the most out of your investment. Use the stack as a single 70GHz OMA system, or use it as four independent oscilloscopes.Whether you are working with 100G coherent transceivers or 1 Terabit long haul communication systems, our OMA can be configured to suit your exact requirements.

  • EMC Test Equipment

    TDEMI G series - Gauss Instruments

    TDEMI stands for a novel generation of EMI measurement systems providing real-time analysis and enabling the user to perform high-quality emission measurements in a fractional amount of time compared to conventional EMI receiver technology. Ultra-fast Analog-to-Digital Conversion as well as real-time signal processing allows to emulate the behavior of instruments like oscilloscopes, receivers and spectrum analyzers. Due to the TDEMI's powerful signal processing hardware platform, corresponding to a computation power of approx. 80 conventional. PCs, such measurements are extremely fast in comparison to state of the art solutions.

  • VirtualBench All-in-One Instrument

    NI

    The VirtualBench All-in-One Instrument combines a mixed-signal oscilloscope with protocol analysis, an arbitrary waveform generator, a digital multimeter, a programmable DC power supply, and digital I/O. The all-in-one features are simple, convenient, and provide more efficient circuit design, debugging, and validation. The included software lets you view all measurements on a single screen and can be updated with free software releases to add functionality and value. The VirtualBench All-in-One Instrument easily integrates with LabVIEW software to provide programmatic control and automated test sequences.

  • PXI Dual 4 to 1 RF Multiplexer 2GHz 50 Ohm SMB

    40-746-511 - Pickering Interfaces Ltd.

    40-740, 40-745 and 40-746 RF Multiplexers are a range of Bi-Directional Multiplexers with bandwidth up to 2000MHz.They are arranged as Single 8 to 1, Dual 4 to 1 or Single 4 to 1 configurations, all with excellent Insertion Loss, VSWR and Isolation, in 50 Ohm or 75 Ohm versions with a wide choice of connectors.Applications include routing high frequency signals to and from oscilloscopes, analyzers, signal generators and synthesizers, telecoms tributary switching (from 2MBit/s to 155MBit/s), video/audio switching and switching high frequency logic signals.

  • Current Probes

    Tektronix, Inc.

    Tektronix current probe solutions offer:*The broadest range of AC/DC and AC-only current probes*Measurement accuracy from uAs to 2000 A*Best-in-class bandwidth up to 120 MHz*Best-in-class current clamp sensitivity down to 1 mA*The only products with 3rd Party Safety Certification (UL, CSA, ETL)*The only products with bare wire voltage ratings*Automatic readout and scaling when used with Tektronix oscilloscopes so you don’t have to convert volts to amps or manually set the scaling

  • Optical Receiver Stress Test Solution

    N4917B - Keysight Technologies

    The N4917B software provides an automated standard compliant stressed receiver sensitivity test according to 100GBASE-LR4, ER4 and SR4 test specification. In order to do this kind of test, several test instruments such as a bit error ratio tester, digital sampling oscilloscope, optical reference transmitter and tunable laser source are required to operate together to achieve a compliant, repeatable optical stressed eye. This stressed eye is then fed to the receiver under test, where bit error ratio is measured under the stress conditions as defined in the standard.

  • Fiber-coupled Polarimeter

    Apex Technologies

    The new AP6051A stand-alone benchtop fiber-coupled polarimeter enables real time monitoring of the SOP, DOP, and power of a light signal in fiber. It can display SOP data information either on a Poincaré sphere, a Jones diagram or on a virtual oscilloscope. Covering the operating wavelength range from 1520 to 1610nm, it offers excellent performance, fast sampling rate,  high SOP accuracy, and wide dynamic input optical power range. Optionally, it can be used in combination with an internal Optical Filter to measure the SOP as a function of frequency. Intuitive software and touch screen allows an easy manipulation of the device.

  • Telephone Line Monitor

    AI-5120 - Advent Instruments Inc.

    The AI-5120 is a compact device designed for monitoring and analyzing signals present on the telephone line. By sensing the voltage present on the telephone line it detects and measures ringing, DTMF & pulse dialing, FSK (Bell 202 and V.23) signals, line polarity reversals, and open switching intervals (OSI). Working in conjunction with the TRsSim software on a PC, the AI-5120 becomes a valuable tool in analyzing and debugging Caller ID and SMS (Short Message Service) data transmission. Like an oscilloscope, it can capture and display waveforms showing various signals present on the telephone line.

  • High-Voltage Differential Probe, 200 MHz

    N2805A - Keysight Technologies

    The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.

  • HDMI Electrical Performance, Validation and Compliance Test Software

    D9021HDMC - Keysight Technologies

    The D9021HDMC HDMI electrical performance validation and compliance software for Infiniium V, Z and UXR-Series oscilloscopes gives you a fast and easy way to verify and debug your High Definition Multi-media Interface (HDMI) designs for set-top boxes, Digital Video Recorders, DVD players, and motherboard systems. The HDMI compliance test software lets you automatically execute HDMI electrical checklist tests and displays the results in a comprehensive report format. In addition to the measurement data, the report provides a margin analysis that shows how closely your device passed or failed each test.

  • AC Electronic Load

    IT8600 Series - I-TECH Electronic Co., Ltd

    IT8600 is ITECH latest series of AC/DC electronic loads with power range 0~14.4 kVA and adjustable frequency 45 Hz ~ 450 Hz. The unique oscilloscope waveform display function of IT8600's can display input voltage & current as waveform. It is equipped with measurement modes for different parameters such as inrush current, peak value, effective value, PF (power factor). Voltage harmonics measurement capacity is up to 50th. The built-in RS232, GPIB, LAN and USB communication interfaces are for reliable and fast control. IT8600 is the perfect solution for testing UPS, inverters, AC power supplies and relevant AC electronic components etc.

  • *Divergent Light Measurement

    mks Ophir

    The IS1.5-VIS-FPD-800 & IS1.5-IRG-FPD-800 contain 2 photodiodes: a calibrated photodiode for precise power measurement using Ophir meters and a fast photodiode with integral reverse bias circuit for temporal characterization using third-party instrumentation such as oscilloscopes and spectrum analyzers. Their small, 1.5" internal diameter preserves the temporal shape of pulses down to 3.5 nsec for VIS and 6 nsec for IRG. An SMA fiber optic connector is provided for connection to a spectrometer. The large, 20 mm input aperture allows for wide acceptance angles and long working distances, making these spheres well suited for testing VCSELs and other types of laser.