Passive Oscilloscope Probes
5900 SERIES
-
Probe Master's new 5900 series passive oscilloscope probes are available in 400 MHz & 500 MHz bandwidths. Probes are also available with readout actuators for oscilloscopes with the readout feature. The "GOLD PROBE" has been designed specifically for use with Tektronix, Hewlett Packard and other high performance oscilloscopes. This new slim design along with a host of versatile accessories, allows you to reach the most difficult test point in today's highly complex circuitry. The gold plated Probe Tips, Sprung Hook, Ground Lead, Alligator Tip and other critical interconnect points within the Gold Probe, provide excellent contacts for probing low level analog signals and high speed digital data. Unlike most "off shore" commodity probes, Probe Master guarantees quality and continuing domestic support for our "Made in America" Gold Probe.The probe body is made of high impact ABS. Soft molded strain reliefs at all stress points assure long cable life. In short it has been designed to offer you high performance coupled with high quality.
-
Product
÷10, 500 MHz, 10 MΩ, Passive Probe (Total of 1 Per Channel)
PP008-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
500 MHz, 1.0 pF Active Differential Probe
ZD500
-
With the ProBus interface, the ZD500, 1000, and 1500 becomes an integral part of the oscilloscope. All probe gain and offset controls are transparent to the user, making it easier to probe the circuit without concern for which gain setting to choose. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
Product
Digital Oscilloscopes
-
Fujian Lilliput Optoelectronics Technology Co., Ltd.
We are one of the leading and professional digital oscilloscopes manufacturers and suppliers in China. Thanks to our highly qualified experts and advanced technology, we are also one of the world's leading brands. Welcome to buy the quality, cheap and durable dso, oscope, digital storage oscilloscope, oscilloscope probe, scope probe in stock from us. Check the quotation with us now.
-
Product
÷10, 500 MHz, 10 MΩ, Passive Probe
PP009-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP021-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
SA2500X, 2.5 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784257-01
Oscilloscope Probe
The SA2500X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
Product
ProBus Probe Adapter for TekProbe-BNC Probes
TPA10
-
- Allows TekProbe interface level II probes to work with any ProBus-equipped Teledyne LeCroy oscilloscope- Automatic probe detection- Provides all necessary power and offset control to the attached probe- Supports probes up to 4 GHz- Easy firmware updates- Wide variety of probes supported including: Preamplifiers, Current Probes, Single-Ended Active Probes and Differential Active Probes
-
Product
Passive Probe, 10:1, 75 MHz, 2-Pack
N2142A
Oscilloscope Probe
The Keysight N2142A is an extremely low-cost passive probe that provides a switchable 10:1 / 1:1 attenuation and up to 75 MHz bandwidth. It features a high input resistance of 10 MΩ (switchable to 1 MΩ) to address a wide range of measurement needs with low probe loading. The probe can be adjusted for both low-frequency compensation and high-frequency compensation. For the best measurements, you should compensate your probe to match its characteristics to the oscilloscope. This probe is compatible with Keysight InfiniiVision Series oscilloscopes with 1 MΩ input.
-
Product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP026-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Aeroscope Wireless Oscilloscope Probe
-
A wireless, ultra-portable oscilloscope with impressive specs – debug circuits in their natural environment.
-
Product
DC-to-250MHz 1:10 Oscilloscope Probe Kit (HP-9250)
PRB-HP-9250
-
Up to 250MHz, Includes a handy storage pouch and includes an IC test-hook adapter for the probe., The BNC connector rotates to avoid cable tangle or kink., Cable length is 1.4 meters.
-
Product
Isolated Hall Effect Current Sensors
-
Isolated Hall Effect current sensors provide accurate high bandwidth current sensing. Vektrex offers models to 320A. For use, the 50-ohm voltage output is connected directly to an oscilloscope or data acquisition system. VCS sensors are magnetically isolated like clamp-on oscilloscope probes. With secure cable attachment, repeatability is ensured.
-
Product
Oscilloscopes And Probes
-
An oscilloscope is quite possibly the most used piece of test equipment on an engineer’s bench. They are used by electrical engineers or anyone else wishing to measure electrical characteristics of electronic devices. However, you need more than just an oscilloscope to complete your job - you also need one or more oscilloscope probes to make accurate measurements.
-
Product
250 MHz Passive Probe for WaveSurfer3000, 10:1, 10 MOhm
PP019-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
DC-to-60MHz 1:10 Oscilloscope Probe Kit (HP-9060 Or HP-3060)
PRB-HP-9060
-
Up to 60MHz, Includes a handy storage pouch and includes an IC test-hook adapter for the probe., The BNC connector rotates to avoid cable tangle or kink., Cable length is 1.4 meters.
-
Product
250 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP017-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
USB Oscilloscope Probes
-
High-performance, passive accessories designed for use with their PC-based oscilloscopes.
-
Product
1 GHz, 1.0 pF Active Differential probe
ZD1000
-
With the ProBus interface, the ZD500, 1000, and 1500 becomes an integral part of the oscilloscope. All probe gain and offset controls are transparent to the user, making it easier to probe the circuit without concern for which gain setting to choose. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
Product
Oscilloscope Probe Kit
6HP-9060
-
Switchable X1/X10/X100 attenuation with reference switch positions. Break-resistant center conductor & wide compensation range. Flatter response, sharper leading edges. Faster rise time and replaceable cable probe head tip and ground lead. Max. input voltage: 600V/1200V (DC-peak AC). Includes BNC adapter, IC tip, insulating tip & trimming tool.
-
Product
2.92mm to ProLink Adapter with Probe Power and Communication Pass Through
L2.92A-PLINK
-
The Teledyne LeCroy LabMaster 10 Zi oscilloscope utilizes precision 2.92mm input connectors to achieve up to 36GHz of input bandwidth. But some applications may require the use of lower-bandwidth probes for performance and cost reasons.The L2.92A-PLINK adapter converts the 2.92mm interface to a ProLink interface. This brings the benefits of a wider selection of probes to the LabMaster 10 Zi such as Dx10/Dx20/Dx00A-AT 4-6 GHz differential probes and DH Series 8 to 20 GHz differential probes using the ProLink oscilloscope probe connection. Full probe power and control is provided through a built-in LEMO interface.
-
Product
SA1000X, 1 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784255-01
Oscilloscope Probe
1 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe - The SA1000X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
Product
1.5 GHz, 1.0 pF Active Differential probe
ZD1500
-
With the ProBus interface, the ZD500, 1000, and 1500 becomes an integral part of the oscilloscope. All probe gain and offset controls are transparent to the user, making it easier to probe the circuit without concern for which gain setting to choose. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
Product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP024-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Passive Probe, 10:1, 500 MHz, 1.5 M
10073D
Oscilloscope Probe
The Keysight 10073D passive probe is our most rugged 500 MHz probe. With a 10:1 attenuation ratio and high 2.2 M ohm input impedance, it is ideal as a general purpose, high bandwidth passive probe for the Keysight 300 MHz - 1 GHz 6000 series, 7000, 8000 and 9000 Series oscilloscopes. The probe identification feature automatically configures the oscilloscope for the probe attenuation.
-
Product
CP400X, 400 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784254-01
High Current Probe
The CP400X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 2 meters in length. The CP400X attaches to BNC connections on both the signal input and instrument sides.
-
Product
10 KV High-Voltage Oscilloscope Probe, CTUVus Listed
CT4432
-
Because an oscilloscope has limits to the input voltage it can accept, measuring higher voltages may sometimes require the use of an attenuating high-voltage probe. The CT4432, with an improved dual-resistor design, can accurately and safely step-down higher voltages to an acceptable level.
-
Product
200 MHz, 3.5 pF, 1 MOhm Active Differential probe
ZD200
-
With the ProBus interface, the ZD200 becomes an integral part of the oscilloscope. The probe sensitivity and offset are automatically optimized based on the oscilloscope gain settings, so control is transparent to the user. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
Product
SP500X , 500 MHz, ±300 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
783629-01
Oscilloscope Probe
The SP500X, or Multi-Contact Isoprobe IV - 10:1, is a standard passive probe with fixed 10x attenuation for oscilloscopes that provide 1 MΩ input impedance.
-
Product
Dual Trace Analog Oscilloscope With Probes
2120C
-
B&K Precision's model 2120C is a dual trace oscilloscope that offers high performance at a low price. Most competitor's entry level oscilloscopes have a 20 MHz bandwidth, while B&K Precision's models 2120C has a bandwidth of 30 MHz. This oscilloscope is built by and backed by B&K Precision, a company that has been selling reliable, durable, value priced test instruments for over 60 years.