Oscilloscope Probes
probe with lead for single-ended measurements connected to ground.
See Also: Oscilloscopes, Analog Oscilloscopes, Digital Storage Oscilloscopes
-
Product
Passive Oscilloscope Probes
5900 SERIES
-
Probe Master's new 5900 series passive oscilloscope probes are available in 400 MHz & 500 MHz bandwidths. Probes are also available with readout actuators for oscilloscopes with the readout feature. The "GOLD PROBE" has been designed specifically for use with Tektronix, Hewlett Packard and other high performance oscilloscopes. This new slim design along with a host of versatile accessories, allows you to reach the most difficult test point in today's highly complex circuitry. The gold plated Probe Tips, Sprung Hook, Ground Lead, Alligator Tip and other critical interconnect points within the Gold Probe, provide excellent contacts for probing low level analog signals and high speed digital data. Unlike most "off shore" commodity probes, Probe Master guarantees quality and continuing domestic support for our "Made in America" Gold Probe.The probe body is made of high impact ABS. Soft molded strain reliefs at all stress points assure long cable life. In short it has been designed to offer you high performance coupled with high quality.
-
Product
Oscilloscope Probes and Accessories
-
Teledyne LeCroy has a wide variety of world class probes and amplifiers to complement its product line. From the ZS high impedance active probes to the DH Series Differential High-bandwidth Probes which offers bandwidths up to 30 GHz, Teledyne LeCroy probes and probe accessories provide optimum mechanical connections for signal measurement.
-
Product
Oscilloscope Probes
-
Connections to the ground of Oscilloscope Probes with the mini PCM Parrot Clip provide improved accessibility , reliability and accuracy. Ground clips for the oscilloscope probe were usually alligator clips but they have poor accessibility in narrow places due to the large jaws.
-
Product
NI-5191, 800 MHz, ±30 V, 10X Attenuation, Differential Active Oscilloscope Probe
781785-01
Oscilloscope
The NI-5191 is a differential, active voltage probe that offers 800 MHz of input bandwidth with a 10:1 attenuation ratio. You can use it with oscilloscopes that provide 50 Ω input impedance. You can power the probe using a Type-N barrel power connector from a USB port or using a 9 V alkaline battery.
-
Product
Probes And Accessories
-
Choose from a broad portfolio of Tektronix probes and accessories, all perfectly matched to our industry-leading oscilloscopes. With over 100 choices available, select the oscilloscope probe you need for your specific testing application. Download our Probe Selector Guide here.
-
Product
200 MHz, 3.5 pF, 1 MOhm Active Differential probe
ZD200
Differential Probe
With the ProBus interface, the ZD200 becomes an integral part of the oscilloscope. The probe sensitivity and offset are automatically optimized based on the oscilloscope gain settings, so control is transparent to the user. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
Product
500 MHz, 1.0 pF Active Differential Probe
ZD500
Differential Probe
With the ProBus interface, the ZD500, 1000, and 1500 becomes an integral part of the oscilloscope. All probe gain and offset controls are transparent to the user, making it easier to probe the circuit without concern for which gain setting to choose. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
Product
DDR4 BGA Interposers, DDR4 DRAM X16 Packages
N2115A
Interposer
The N2115A DDR4 BGA Interposers are soldered in between the DRAM and PC board or DIMM raw card where the DRAM would normally be soldered. They are designed with the PCB or DIMM foot print on the bottom side and the DRAM footprint on the top side. The signals from the memory controller chip and DRAM are then passed directly to the top side of the BGA probe adapter where they can be accessed with the oscilloscope probes.
-
Product
250 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP017-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP021-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP022-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
T3DSO Passive Probe, 350 MHz, 1X/10X, 1 MOhm/10 MOhm, 300V/600V
T3PP350
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
Passive Probe, 10:1, 200 MHz, 2-Pack
N2140A
Oscilloscope Probe
The Keysight N2140A is an extremely low-cost passive probe that provides a switchable 10:1 / 1:1 attenuation and up to 200 MHz bandwidth. It features a high input resistance of 10 MΩ (switchable to 1 MΩ) to address a wide range of measurement needs with low probe loading. The probe can be adjusted for both low-frequency compensation and high-frequency compensation. For the best measurements, you should compensate your probe to match its characteristics to the oscilloscope. This probe is compatible with Keysight InfiniiVision Series oscilloscopes with 1 MΩ input.
-
Product
T3DSO Passive Probe, 350 MHz, 10X, 10 MOhm, 300V/600V
T3PP350A
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
Isolated Hall Effect Current Sensors
-
Isolated Hall Effect current sensors provide accurate high bandwidth current sensing. Vektrex offers models to 320A. For use, the 50-ohm voltage output is connected directly to an oscilloscope or data acquisition system. VCS sensors are magnetically isolated like clamp-on oscilloscope probes. With secure cable attachment, repeatability is ensured.
-
Product
SP200B, 200 MHz, ±60 V, 1X or 10X Attenuation, Single-Ended Passive Oscilloscope Probe
780284-01
Oscilloscope Probe
The SP200B is a standard switchable passive probe for oscilloscopes that provide 1 MΩ input impedance. Depending on the attenuation ratio, the probe has an analog bandwidth of 6 MHz in the 1x attenuation setting or 200 MHz in the 10x attenuation setting.
-
Product
CP500X, 500 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784253-01
High Current Probe
The CP500X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 1 meter in length. The CP500X attaches to BNC connections on both the signal input and instrument sides.
-
Product
Differential Voltage Probes
DP150/DP200pro
-
The DP differential isolation probes are an important accessory for any laboratory involved in power electronics and high voltage systems. These probes allow isolated and floating measurements with any oscilloscope or data recorder, whilst the oscilloscope can remain grounded. Using a DP150 or DP200pro probe, differential and floating measurements can be made on a variety of ac power systems like 230V/110V ac input power supplies, chopped and switching power supplies, thyristor controllers, variable speed motor drives (PWM signals), motor inrush current and measurement across current shunts. The isolated input is made via two 4mm/banana safety sockets. The BNC output allows easy connection to an oscilloscope. The DP probes can be powered from a 9V battery or external power supply.
-
Product
USB Oscilloscope Probes
-
High-performance, passive accessories designed for use with their PC-based oscilloscopes.
-
Product
Low Voltage Differential Oscilloscope Probes
-
Differential signaling used in high speed serial standards requires very accurate characterization. The industry-leading bandwidth and signal fidelity found in a Tektronix low voltage differential oscilloscope probe ensures that you see every possible detail. Tektronix offers TriMode™ architecture which streamlines measurement acquisition by enabling you to make differential, single-ended, and common mode measurements with a single connection!
-
Product
2.92mm to ProLink Adapter with Probe Power and Communication Pass Through
L2.92A-PLINK
-
The Teledyne LeCroy LabMaster 10 Zi oscilloscope utilizes precision 2.92mm input connectors to achieve up to 36GHz of input bandwidth. But some applications may require the use of lower-bandwidth probes for performance and cost reasons.The L2.92A-PLINK adapter converts the 2.92mm interface to a ProLink interface. This brings the benefits of a wider selection of probes to the LabMaster 10 Zi such as Dx10/Dx20/Dx00A-AT 4-6 GHz differential probes and DH Series 8 to 20 GHz differential probes using the ProLink oscilloscope probe connection. Full probe power and control is provided through a built-in LEMO interface.
-
Product
500 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP018-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
WiFi Oscilloscope Probe
IkaScope
-
IkaScope is a wireless oscilloscope probe. It fits perfectly in your hand and works with any connected screen, like a laptop, a tablet or smartphone. Thanks to ProbeClick® technology, IkaScope knows when to measure and when to hold. IkaScope transfers measured signals over high speed wifi connection. 200 MSa/S Sampling rate. 30 MHz Bandwidth. 80 Vpp Input range. AC/DC Coupling. 4000 ptsMemory. 200 FPS Max. refresh rate.
-
Product
SA1500X, 1.5 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784256-01
Oscilloscope Probe
The SA1500X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
Product
Oscilloscope Probe
Oscilloscope
Oscilloscope Probes can conduct signals up to 2.5 GHz, 300 V, or 500 Arms, even in extreme environments. They offer fixed attenuation of 10X or 100X or switchable attenuation between 1X and 10X. Oscilloscope Probes are offered in several types, including single-ended and differential, active and passive, voltage and current.
-
Product
Passive Probe, 500 MHz, 10:1, 1 MOhm/10 MOhm
PP020-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
SP500X , 500 MHz, ±300 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
783629-01
Oscilloscope Probe
The SP500X, or Multi-Contact Isoprobe IV - 10:1, is a standard passive probe with fixed 10x attenuation for oscilloscopes that provide 1 MΩ input impedance.
-
Product
Digital Oscilloscopes
-
Fujian Lilliput Optoelectronics Technology Co., Ltd.
We are one of the leading and professional digital oscilloscopes manufacturers and suppliers in China. Thanks to our highly qualified experts and advanced technology, we are also one of the world's leading brands. Welcome to buy the quality, cheap and durable dso, oscope, digital storage oscilloscope, oscilloscope probe, scope probe in stock from us. Check the quotation with us now.
-
Product
DMM Terminal Test Lead
U1580A
Accessory Kit
The Keysight U1580A test leads are compatible with the U1600A Series handheld digital oscilloscope probes and test leads. These test leads are used for the DMM terminal on the oscilloscopes.
-
Product
Oscilloscopes
-
Get your products to market faster with award-winning oscilloscopes that offer the fastest update rates, the deepest memory, the industry’s only capacitive touch screen, and the most oscilloscope software options Produce the highest-performing products with measurements you can trust thanks to oscilloscopes with industry-leading signal integrity and the largest selection of oscilloscope probes Achieve the lowest cost of ownership with multiple instruments in one mainframe and easy upgrades