Product
14-Bit AWQ, 2 GSPS Waveform Generator
SDR14TX
Waveform Generator
The SDR14TX is a dual-channel flexible arbitrary waveform generator (AWG). It offers an outstanding combination of high bandwidth and dynamic range which enables generation of wideband signals.
-
Product
PXIe-5633, 26.5 GHz PXI Vector Network Analyzer
788182-18
Vector Network Analyzer
The PXIe-5633 is a single-slot PXIe Vector Network Analyzer (VNA) that helps you streamline your production test applications. This VNA supports automatic and manual precision calibration, full vector analysis, de-embedding, and pulsed S-parameter capabilities, making it ideal for validation and production operations without the high costs and large footprints associated with traditional benchtop VNAs. The PXIe-5633 also integrates into NI RFmx and Instrument Studio software to provide automated control for test program development. Additionally, the PXIe-5633 features a hardware pass-through path that you can use for PXI Vector Signal Transceivers (VSTs) testing directly at the VNA ports. With combined modulated and S-parameter measurements on a single connection, you can cover both VST and VNA tests on a single device.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3G
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Signal, Patchcord, Receiver, 36", TriPaddle, 24 AWG White, Single Ended (3 Amp)
7-104924000-036
Signal Patchcord
Signal, Patchcord, Receiver, 36", TriPaddle, 24 AWG White, Single Ended (3 Amp).
-
Product
Signal, Patchcord, ITA, 36", QuadraPaddle, 24 AWG Twisted Pair Shielded, White/White-Blue, Single Ended
7-121425000-036
Signal Patchcord
Signal, Patchcord, ITA, 36", QuadraPaddle, 24 AWG Twisted Pair Shielded, White/White-Blue, Single Ended.
-
Product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-F
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
Product
Standard 2.00 (57.00) - 6.00 (170.00) Non Replaceable General Purpose Probe
F-S-R
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
Product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-W
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
Product
Astronics PXIe-1209 , 2-Channel, 100 MHz PXI Pulse Generator
785033-01
Pulse Generator
2-Channel, 100 MHz PXI Pulse Generator - The Astronics PXIe-1209 provides dual independent pulse generation with full control of all timing parameters with extremely high resolution. Both channels are fully independent, and you can configure pulse delay, double pulse spacing, pulse width, and period. Each channel offers front panel trigger inputs with software-programmable thresholds and PXI backplane triggering.
-
Product
Signal, Contact, Receiver, QuadraPaddle, 5 Amp, Male Adapter, .025" Round Post (Adapter Pin)
610138117
Signal Contact (Receiver)
Primary mating contact 610138100. (May mate with other Twin Female contacts, as well.)
-
Product
Alternate 2.52 (71.00) - 6.50 (184.00) General Purpose Probe
EPA-3G-1
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
250 MS/s, Two Channel, Arbitrary Waveform Function Generator PXI Card
GX1120
Waveform Generator
The GX1120 is a high performance, two-channel PXI arbitrary waveform generator that offers function generator and arbitrary waveform generator functionality within one instrument. Built-in waveforms are available for use with both the DDS or AWG modes of operation and include Sine, Triangle, Ramp, Noise, and pulse waveform generation.
-
Product
Streamline Vector Network Analyzer, 9 KHz To 4.5 GHz, 2-port
P5000B
Vector Network Analyzer
Compact, faceless, vector network analyzer (VNA). Flexible two-port VNA dramatically reduces your size of test. Up to 4.5 GHz.
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Non Replaceable General Purpose Probe
MEP-20U
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
Product
Alternate 1.00 (28.00) - 2.00 (57.00) General Purpose Probe
P2663G-1V2S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
Product
Alternate 1.30 (37.00) - 4.50 (128.00) General Purpose Probe
HPA-1B-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2F
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
PXIe-5654, 250 kHz to 20 GHz, PXI RF Analog Signal Generator
784777-02
Signal Module
PXIe, 250 kHz to 20 GHz, PXI RF Analog Signal Generator - The PXIe-5654 features a combination of exceptional phase noise and frequency tuning time. These features address applications such as blocker test/receiver desensitization, high-performance intermodulation distortion measurements, and various electronic warfare applications. The PXIe-5654 is designed to meet the challenging requirements of RFIC characterization, satellite test, and radar applications. Some PXIe-5654 options include a PXIe-5696 Amplitude Extender Module. The PXIe-5696 supports a frequency range of 250 kHz to 20 GHz and an extended amplitude range up to 27 dBm.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T135
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
FieldFox Handheld RF Vector Network Analyzer
N9923A
Vector Network Analyzer
4/6 GHz max frequency Carry the world's most accurate handheld RF T/R VNA analyzer Expand capabilities with optional 2-port VNA, time-domain, vector voltmeter, cable and antenna analyzer and more Save time by simultaneously measuring all four S-parameters (S11, S21, S12, S22) with a single connection Perform accurate testing with QuickCal, full 2-port unknown thru Cal, TRL Easily measure average and puls
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4G
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
High 4.00 (113.00) - 6.70 (190.00) General Purpose Probe
P2550-0-8
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
Product
PXI Breadboard Module, 2-Slot, No Connector
40-220A-102
Signal Module
The 40-220A series of breadboard modules allow the user to construct their own circuit in situations where a suitable PXI module is not available. For example when it is required to integrate a non-switching function into a PXI chassis. Typical applications include: Creating custom circuitry that can be housed in on a 3U board, or to build special one-off switching modules.
-
Product
PXI-5421, 43 MHz Bandwidth, 16-Bit PXI Waveform Generator
778697-02
Waveform Generator
43 MHz Bandwidth, 16-Bit PXI Waveform Generator—The PXI‑5421 is a 43 MHz arbitrary waveform generator capable of generating user-defined, arbitrary waveforms and standard functions including sine, square, triangle, and ramp. This arbitrary waveform generator can generate signals from -6 V to +6 V and uses direct digital synthesis (DDS) to precisely generate waveforms. The PXI‑5421 also features advanced synchronization and data streaming capabilities.
-
Product
Alternate 2.64 (75.00) - 6.50 (184.00) General Purpose Probe
EPA-2F-1
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Ethernet/LXI generatorNETBOX 16 Bit Arbitrary Waveform Generator - up to 40 MS/s on 16 Channels
DN2.653-16
Arbitrary Waveform Generator
The generatorNETBOX DN2.65x arbitrary waveform generators (AWG) is a general purpose multi-channel AWG with outstanding dynamic performance. The series includes LXI units with either four, eight or 16 synchronous channels. The large onboard memory can be segmented to replay different waveform sequences.
-
Product
Keysight Streamline USB Vector Network Analyzer, 6.5 GHz
P9371A
Vector Network Analyzer
Compact, faceless, USB vector network analyzer (VNA). Affordable full two-port VNA which dramatically reduces your size of test. Up to 6.5 GHz.
-
Product
SSA Signal Source Analyzer, 10 MHz to 7 GHz, 26.5 GHz, or 110 GHz
E5052B
Signal Analyzer
RF Input frequency range: 10 MHz to 110 GHz Analysis offset frequency range: 1 Hz to 100 MHz Phase noise measurement with ultra low noise floor and a cross-correlation method Frequency transient capture range: up to 80 MHz in narrow band, up to 4.8 GHz in wide band
-
Product
Streamline USB Vector Network Analyzer, 32 GHz
P5026A
Vector Network Analyzer
Compact, faceless, USB vector network analyzer (VNA). Flexible two-port VNA which dramatically reduces your size of test. Up to 32 GHz.
-
Product
Signal, Patchcord, ITA, 36", TriPaddle, 22 AWG White, Single Ended ( 5 Amps)
7-103922000-036
Signal Patchcord
Signal, Patchcord, ITA, 36", TriPaddle, 22 AWG White, Single Ended ( 5 Amps).