Techimp HQ S.r.L
Horn antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in electric assets like GIS and GIL or MV and HV power transformers. It is a broadband antenna with a flat response which makes Horn antenna suitable in a number of different applications. It has been optimized to operate in a frequency range suitable for PD activity monitoring and it was designed to provide maximum sensitivity and high gain.
-
YDSW Series -
Shanghai Jiuzhi Electric Co., Ltd.
SF6 insulated Test Transformers are especially designed for testing metal-clad switchgear (GIS) in the factory and in the field, and for testing the other substation equipment. It is also the portable and easy maintenance solution. The SF6 test transformers can be flanged directly to the GIS for testing which make the partial discharge test easy and quick. These systems are particularly suited for on-site tests of GIS after installation. In the factory, they are used to test sub-assemblies and components directly in the manufacturing line.
-
Power Diagnostix Systems GmbH
Partial discharge testing – well established for high voltage equipment – becomes increasingly important for insulation systems of a lower voltage level. Changing to switching power supply and to IGBT control of induction motors, for instance, raise demands and testing needs for the insulation system. The modular concept of Power Diagnostix’ instruments allows offering customized solutions for automated and semi-automated testing.
-
Kikusui Electronics Corp.
a high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.
-
FMC -
Techimp HQ S.r.L
The FMC (Flexible Magnetic Coupler) is a partial discharge sensor whose working principle is based on a direct magnetic coupling with the cable conductor and shield.It picks up a magnetic signal given by PD activity. His compact and robust design makes the FMC the optimal sensor for direct installation on cables and accessories such as joints and termination.This sensor has a sensitive side which has to face to the object under test, while the other side (shielded) reject the noise from the environment.
-
Soken Electric Co. Ltd
Insulation materials in electrical equipment are used between a pair of electrodes; therefore it can be expressed as capacitors. Applying AC voltage to a capacitor with insulation materials causes an energy loss due to the leak current, the dielectric polarization, and the partial discharge. Because of this, the phase of the capacitor current is more delayed than that of a zero-loss current (reactive current) flowing in an ideal insulation material. The delay angle is called "Dielectric Loss Angle", and the tangent is "Dielectric Loss Tangent" (tanδ). Please refer to the technical guide explained in detail.
-
Weshine Electric Manufacturing Co., Ltd
High-voltage Dividers (High Potential Divider) are used to measure voltages and decouple partial discharges in high-voltage test systems. Depending on the specific type, they are used to measure alternating voltage (AC), direct voltage (DC), lightning impulse voltage (LI), and switching impulse voltage (SI) systems. High-voltage dividers by HIGHVOLT comply with the relevant IEC standards. The systems are available for both indoor and outdoor use.
-
Spark P3 -
Manta Test Systems
Doble Spark P3 is a universal partial discharge (PD) and electromagnetic interference (EMI) analyzer that uses a software defined radio signal detector to identify characteristics of insulation system deterioration that could lead to the failure of high voltage equipment. It detects signals from suitable sensors in a frequency range between 9 kHz to 2 GHz for PD and EMI, and DC to 500k Hz for acoustic and reference voltage measurements.
-
Chroma 11210 -
Chroma Systems Solutions, Inc.
Chroma 11210 battery cell insulation tester is an instrument used for accurately measuring leakage current (LC) and insulation resistance(IR) of battery jelly-roll/dry-cell as well as other insulation materials. In addition to standard LC/IR measurement, the 11210 has a unique function that detects partial discharge (PD) or flashover that may have occurred inside the insulation material during the high voltage insulation testing process.
-
SonaVuTM -
SDT Ultrasound Solutions
SonaVu™ is an acoustic imaging camera. Using its 112 ultrasound sensors and optical camera, it can detect sources of airborne ultrasound and transmit them into a visual image on its touch screen. Defects such as compressed air system leaks, compressed gas system leaks, vacuum leaks, the presence of partial discharge on electrical assets, and failed/working steam traps all create turbulence. And when there is turbulent flow present, there is airborne ultrasound. SonaVu™ makes the superhuman hearing capabilities of SDT Ultrasound Devices visible to the human eye.
-
Techimp HQ S.r.L
TEV sensor is a partial discharge sensor whose working principle is based on a direct Capacitive coupling with a Switchgears earthed metal case. The two ends of TEV sensor can be coupled magnetically to virtually any opening on a metal Surface. It picks up the electric signal given by PD activity onto the two metallic surfaces. Thanks to its special design has high sensitivity, larger than other single ended TEV sensors. His compact and robust design (passive sensor) makes the TEV the optimal sensor for direct installation on medium voltage Switchgears.
-
Premier Electrosystems
The typical use of high voltage testing is to confirm performance. The high voltage tests are included in type and routine tests to meet the required IS standards, quality and reliability. Some of them are insulation resistance tests, dielectric type tests, lightning and switching impulse tests, partial discharge measurement, etc. Premier's high voltage tester checks the insulation between line to earth, neutral to earth, primary to earth, secondary to earth and between primary & secondary.
-
HFCT Ø 140mm -
Techimp HQ S.r.L
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
Power Monitoring and Diagnostic Technology Ltd.
PMDT is the only manufacturer to utilize all 5 types of online partial discharge sensor technology. Using multiple sensing methods ensures that PD activity is always discovered, located, and characterized. PMDT's handheld PDetector and PDStar units have more capability than the high-end diagnostic equipment of the past. The small handheld, battery powered unit can completely perform the test and analysis without the need of a PC. PDetector, PDStar, and PDiagnostic instruments feature high-resolution phase-resolved analysis of PD signals (PRPD and PRPS) in real time, so you get your test results instantly!
-
Techimp HQ S.r.L
UHF Spiral antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in the monitored asset. It is a broadband antenna with a flat response which makes Spiral antenna suitable in a number of different applications. It has been optimized to operate in a frequency range typical for PD activity and it was designed to provide maximum sensitivity and high gain. Its compact and robust design (passive sensor) makes Spiral antenna the optimal sensor for direct installation on high voltage Transformers. It can be virtually applied in any electrical equipment provided that it has apertures or EM transparent surfaces. Contact our sales department for consulting.