Filter Results By:

Products

Applications

Manufacturers

Chassis

Infrastructure housing for instrument cards typically containing a power supply, cooling fans and emi shielding.

See Also: PXI Chassis, Modular Instruments


Showing results: 1471 - 1485 of 1598 items found.

  • RF Matrix Switch for Wireless Technologies up to 4 GHz

    NEXUS-4 - Quintech Electronics and Communications Inc.

    The NEXUS-4 is a bi-directional fully non-blocking 3232 RF matrix switching system that can route any input ports to any outputs in a 6 RU chassis. With the frequency range of 700 MHz to 4 GHz and the capability of expanding to 256256, it enables large scale wireless testing that involves many MIMO base stations and devices. The built-in programmable attenuators and efficient automation interface provide ease-of-use testing of signal fade and emulation of mobility scenarios. It can dramatically increase lab efficiency by eliminating manual patch panel and cabling as it can be remotely reconfigured for different test setups consistently in seconds.

  • Switch Modules - 32 Single Pole Relays Arranged as a 16x2 Matrix

    JX32/AB-1 - Cytec Corp.

    This module has 32 single pole relays arranged as a 16x2 matrix as shown in the figure to the left. The matrix may be operated and wired individually for up to 16 16x2's per chassis, or jumpered to the backplane to form up to a 256x2 matrix. It is available with Type S or M reed relays for high speed, long life application. These modules are usually used for 2 wire testing where high and low meter leads must be switched between any two points. Often used for 2 wire LCR meter measurements, cable testing, or open / short testing in a variety of applications.

  • Switch Modules - 16 Single Pole Relays Arranged as an 8x2 Matrix

    JX16/AB-1 - Cytec Corp.

    This module has 16 single pole relays arranged as an 8x2 matrix as shown in the figure to the left. The matrix may be operated and wired individually for up to 16 8x2's per chassis, or jumpered to the backplane to form up to a 128x2 matrix. It is available with Type S or M reed relays for high speed, long life application. These modules are usually used for 2 wire testing where high and low meter leads must be switched between any two points. Often used for 2 wire LCR meter measurements, cable testing, or open / short testing in a variety of applications.

  • Surface Insulation Resistance Testing

    AutoSIR2™ - Gen3 Systems Limited

    One AutoSIR chassis can hold between 1 to 16 measurement cards and can monitor up to 256 x 2-point test patterns or 78 x 5-point test patterns, or 32 x 9-point test patterns at selectable intervals from minutes to days. Each channel is current limited (1 M Ω), ensuring that dendrites are preserved for failure analysis. The frequent monitoring capability provides a full picture of the electrochemical reactions taking place on a circuit assembly, and provides early trend analysis enabling tests to be curtailed, thus saving considerable test time and money.

  • NI-9861, 1-Port, Low-Speed/Fault Tolerant C Series CAN Interface Module

    781962-01 - NI

    1-Port, Low-Speed/Fault Tolerant C Series CAN Interface Module—The NI‑9861 is a fault-tolerant Controller Area Network (CAN) interface for developing applications with the NI‑XNET driver. The NI‑9861 is ideal for applications requiring real-time, high-speed manipulation of hundreds of CAN frames and signals, such as hardware‑in‑the‑loop simulation, rapid control prototyping, bus monitoring, automation control, and more. You can perform this manipulation while taking other data acquisition measurements in the same NI CompactDAQ hardware platform or while performing low-level FPGA control and embedded monitoring in the same NI CompactRIO chassis.

  • Astronics PXIe-3352, Rubidium PXI Synchronization Module

    785034-01 - NI

    PXIe, Rubidium PXI Synchronization Module - The PXIe-3352 generates high-stability clock signals for PXI or third-party instrumentation. It provides a high-accuracy sine wave, square wave, or 1 pps output, and it includes a built-in GPS receiver (external antenna required) to discipline the rubidium oscillator for long-term stability. The front panel DC power input maintains power to the rubidium oscillator if the PXI chassis is powered off, keeping the rubidium oscillator stable over time and eliminating the effects of retrace. The GPS receiver also maintains its location information during power off for fast system bring up.

  • sbRIO-9866, Non-Enclosed, 1-Port C Series LIN Interface Module

    785965-01 - NI

    Non-Enclosed, 1-Port C Series LIN Interface Module—The sbRIO‑9866 is a Local Interconnect Network (LIN) interface for developing applications with the NI‑XNET driver. The sbRIO‑9866 excels in applications requiring real-time, high-speed manipulation of hundreds of LIN frames and signals such as hardware‑in‑the‑loop (HIL) simulation, rapid control prototyping, bus monitoring, automation control, and more. You can perform this manipulation while taking other DAQ measurements in the same CompactDAQ hardware platform or while performing low-level FPGA control and embedded monitoring in the same CompactRIO Chassis. Non-enclosed modules are designed for OEM applications.

  • PXIe-7915, KU060 FPGA, 4 GB DRAM, x8 Gen 3 PXI Coprocessor Module

    785174-01 - NI

    The PXIe-7915 provides a Xilinx Kintex UltraScale FPGA that you can program with LabVIEW or Xilinx Vivado to add signal-processing capabilities to PXI Express systems. Using the x8 Gen 3 PCI Express architecture and peer-to-peer streaming, PXI FlexRIO Coprocessor Modules can stream data to and from other modules in a PXI chassis at up to 7 GB/s without a host controller. You can pair these modules with another PXI instrument, such as a PXI Vector Signal Transceiver, to add functionality, such as running complex algorithms in real-time. The PXIe-7915 KU060 FPGA is ideal for RF applications that require a substantial amount of signal processing.

  • PXIe-7912, KU040 FPGA, 4 GB DRAM, x8 Gen 3 PXI Coprocessor Module

    785173-01 - NI

    The PXIe-7912 provides a Xilinx Kintex UltraScale FPGA that you can program with LabVIEW or Xilinx Vivado to add signal-processing capabilities to PXI Express systems. Using the x8 Gen 3 PCI Express architecture and peer-to-peer streaming, PXI FlexRIO Coprocessor Modules can stream data to and from other modules in a PXI chassis at up to 7 GB/s without a host controller. You can pair these modules with another PXI instrument, such as a PXI Vector Signal Transceiver, to add functionality, such as running complex algorithms in real-time. The PXIe-7912 KU040 FPGA is ideal for applications that require a moderate amount of signal processing.

  • PXIe-7911 , KU035 FPGA, x8 Gen 3 PXI Coprocessor Module

    785172-01 - NI

    The PXIe-7911 provides a Xilinx Kintex UltraScale FPGA that you can program with LabVIEW or Xilinx Vivado to add signal-processing capabilities to PXI Express systems. Using the x8 Gen 3 PCI Express architecture and peer-to-peer streaming, PXI FlexRIO Coprocessor Modules can stream data to and from other modules in a PXI chassis at up to 7 GB/s without a host controller. You can pair these modules with another PXI instrument, such as a PXI Vector Signal Transceiver, to add functionality, such as running complex algorithms in real-time. The PXIe-7911 KU035 FPGA is ideal for applications that require a moderate amount of signal processing.

  • PCI-6123, 8 AI (16-Bit, 500 kS/s/ch), 8 DIO, PCI Multifunction I/O DeviceMultifunction I/O Device

    779409-01 - NI

    8 AI (16-Bit, 500 kS/s/ch), 8 DIO, PCI Multifunction I/O Device - The PCI‑6123 is a simultaneous-sampling, multifunction DAQ device. It offers analog input, digital I/O, two 24‑bit counters, and digital triggering. The PCI‑6123 is ideal for a variety of applications, such as IF digitization; transient recording; ISDN, ADSL, and POTS manufacturing test in the telecom industry; ultrasound and sonar testing; and high-energy physics. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements. The PCI‑6123 dimensions require chassis slots that can accommodate full-length PCI modules.

  • PCI-6123, 8 AI (16-Bit, 500 kS/s/ch), 8 DIO, PCI Multifunction I/O Device

    779408-01 - NI

    8 AI (16-Bit, 500 kS/s/ch), 8 DIO, PCI Multifunction I/O Device - The PCI‑6123 is a simultaneous-sampling, multifunction DAQ device. It offers analog input, digital I/O, two 24‑bit counters, and digital triggering. The PCI‑6123 is ideal for a variety of applications, such as IF digitization; transient recording; ISDN, ADSL, and POTS manufacturing test in the telecom industry; ultrasound and sonar testing; and high-energy physics. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements. The PCI‑6123 dimensions require chassis slots that can accommodate full-length PCI modules.

  • NI-9381, 8 AI, 8 AO, 4 DIO, 0 V to 5 V, C Series Multifunction I/O Module

    782580-01 - NI

    8 AI, 8 AO, 4 DIO, 0 V to 5 V, C Series Multifunction I/O Module - The NI‑9381 is a single, cost-effective module for general-purpose system I/O. The NI‑9381 combines common I/O circuitry into a single module to help system designers fit more functionality into a single system. The analog circuitry on the NI‑9381 is a multiplexed architecture that shares a single timing engine. The maximum sample rate per channel is divided by the number of both analog input and analog output channels in use. The NI‑9381 is supported in only CompactRIO Chassis.

  • NI-9381, 8 AI, 8 AO, 4 DIO, 0 V to 5 V, C Series Multifunction I/O Module

    782580-02 - NI

    8 AI, 8 AO, 4 DIO, 0 V to 5 V, C Series Multifunction I/O Module - The NI‑9381 is a single, cost-effective module for general-purpose system I/O. The NI‑9381 combines common I/O circuitry into a single module to help system designers fit more functionality into a single system. The analog circuitry on the NI‑9381 is a multiplexed architecture that shares a single timing engine. The maximum sample rate per channel is divided by the number of both analog input and analog output channels in use. The NI‑9381 is supported in only CompactRIO Chassis.

  • NI-9220, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle

    865685-01 - NI

    NI-9220, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle - The USB Voltage Measurement Bundle with NI-9220, cDAQ-9171, and cRIO-9940 includes the NI-9220 C Series Voltage Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9220 features 16 channels and 16 simultaneous differential analog inputs with 250 Vrms CAT II or 60 VDC CAT I isolation. Additionally, you can use the NI-9220 to generate 3.2 MB/s of data at the maximum sampling rate.

Get Help