Showing results: 1411 - 1425 of 1566 items found.
-
Virginia Panel Corporation
Our customers have shared a long history of using printed circuit boards (PCB) in the interchangeable test adapters (ITAs) of their automated test equipment (ATE) stations. Whether you are designing a self-test fixture, looking to save space, improve signal integrity, or reduce cable management concerns, Virginia Panel Corpoation has a team of engineers to help you design, manufacture, and integrate PCBs into your ATE system.
-
Extech 380396 -
Extech Instruments Corporation
With the 380396 measure Insulation Resistance to 60GΩ with test voltages of 500V, 1000V, 2500V, and 5000V. Featuring polarization Index measurement (PI), Dielectric Absorption Ratio measurement (DAR), AC/DC Voltage measurement to 600V with Min/Max, Peak and Relative functions, and 1 to 15 minute timer function for IR measurements. Comes with test leads, eight C batteries, 220V AC adaptor, heavy duty carrying case, and user manual.
-
Extech 380395 -
Extech Instruments Corporation
With the 380395 measure Insulation Resistance to 60GΩ with test voltages of 500V, 1000V, 2500V, and 5000V. Featuring polarization Index measurement (PI), Dielectric Absorption Ratio measurement (DAR), AC/DC Voltage measurement to 600V with Min/Max, Peak and Relative functions, and 1 to 15 minute timer function for IR measurements. Comes with test leads, eight C batteries, 120V AC adaptor, heavy duty carrying case, and user manual.
-
33900 -
S & G Tool Aid Corp
Test gasoline fuel pump pressure on most domestic and imported fuel injection equipped vehicles.Kit contains adapters to test all GM vehicles with Multi-port and some Throttle Body Injection (TBI). Test all Chrysler cars with Multi-port turbos and some TBI.Use on older Ford TBI systems not equipped with small Schrader test valve.Includes Large Gage with hang-up hook calibrated from 1-100 PSI (0-7.0 BAR).
-
LXinstruments GmbH
The modular OTP system (Open Test Platform) is based on a flexible instrumentation matrix plus LXI-based sources and measurement instruments in combination with a high-quality transfer interface for test adapter connections. This system can be easily enhanced with customer- and application-specific functions. This enables us to build systems which exactly fit your requirements, and are at the same time economical due to standardization.The OTP² system platform is now available in a PXI as well as an LXI variant.
-
UTP 9011 RF -
NOFFZ Computer Technik GmbH
Circuit boards are the heart of all electronic devices. To ensure the reliable function of these boards, detailed tests are essential.Our board-level tester UTP 9011 RF works safely, quickly and cost-optimized at circuit board level. Our interchangeable adapters are particularly efficient in this system, with which you can even test different test items at the same time. The shielded NOFFZ HF test chamber always ensures consistently good results.
-
In-Phase Technologies, Inc.
Our analog and digital automated test system experience covers a wide variety of applicationsfrom multiple path resistance, capacitance, and inductance testing using various Interface Test Adapters (ITA)to inter-connect multiple customer units under test (UUT). Other systems have included: equipment to monitor and record telemetry, digital data streams, and systems that evaluate packet data using a variety of VME, VXI, PXI, and LXI equipment.
-
Voltstik -
SensorLink
The Voltstik is a distribution voltage voltmeter designed for use on lines and in substations. This meter is employed onto a line by using a hot stick and universal chuck adapter. It is capable of measuring voltage phase to phase, and phase to ground. This high impedance instrument is an excellent choice for solving multiple problems associated with operating a medium voltage system. Its key applications are defined under three groups, safety confirmation of the voltage present, troubleshooting voltage problems, and phasing.
-
ES-9810/xx -
Excalibur Systems, Inc.
The ES-9810/xx is a rugged ethernet system supporting up to four independent 8000 family avionics communication modules, allowing multiple different protocols to be mixed and matched in a single system. Modules available include MIL-STD-1553, MIL-STD-1760, MMSI, ARINC-429, ARINC-708, ARINC-717, Serial, Discrete and CAN bus.The ES-9810/xx is supplied with C drivers, including source code. Mating connectors and cable adapters for I/O connection can be purchased seperately.
-
53900 -
S & G Tool Aid Corp
Quick couplers provide for fast and easy hook-up. Kit contains adapters to test all GM vehicles with Multi-port and some Throttle Body Injection (TBI). Tests all Chrysler cars with Multi-port turbos and some TBI. Use on Ford older TBI systems not equipped with small Schrader test valve. Includes Large Gage with hang-up hook calibrated from 1-100 PSI (0-7.0 BAR). Supplied with instructions in a vinyl pouch.
-
DEL-101 -
Standard Electric Works Co., Ltd
● Mains wiring polarity check.● ELCB/RCD testing.● Measuring ear for line current.● Measuring ear for leakage current.● Helps calculate insulation resistance.● Helps calculate power consumption.● Helps fault finding of standing earth fault.● Fused main adapter.● Appliance testing (with the aid of a clamp meter).● Fused appliance socket.● No batteries required.● HRC fuse inside.● Fused, color-coded universal test sockets.● Universal mains IEC Lead.
-
Analog Discovery 2 -
Digilent Inc.
Digilent Analog Discovery 2, developed in conjunction with Analog Devices and supported by Xilinx University Program, is a multi-function instrument that allows users to measure, visualize, generate, record, and control mixed signal circuits of all kinds. The low-cost Analog Discovery 2 is small enough to fit in your pocket, but powerful enough to replace a stack of lab equipment, providing engineering students, hobbyists, and electronics enthusiasts the freedom to work with analog and digital circuits in virtually any environment, in or out of the lab. The analog and digital inputs and outputs can be connected to a circuit using simple wire probes; alternatively, the Analog Discovery BNC Adapter and BNC probes can be used to connect and utilize the inputs and outputs. Driven by the free WaveForms 2015 (Mac, Linux and Windows Compatible) software, Analog Discovery 2 can be configured to work as any one of several traditional instruments.
-
bsw TestSystems & Consulting AG
The complexity of DC Parametric Characterisations has significantly increased with the level of miniaturisation in the semiconductor industry. The demand is not only on the precision of the measurements. New measurement methods have emerged to gain insight into phenomena previously unknown or only of marginal relevance. One example is "Pulsed IV" which is now widely in use. The modular concept of the Keysight B1500A allows users to tailor their instrument exactly to their needs. Flexible upgrades ensure the investment for many years. Together with bsw AG you will get an optimum solution for your application. Our experts provide not only support for the instrument itself but have also working knowledge of all the solutions surrounding it. This includes Cabeling and Adapters, Fixturing for packaged Parts and of course Wafer Probing. We help customers from replacements of broken or worn-out parts to planning and deployment of turn-key-systems.
-
32645 -
LINDY-Elektronik GmbH
This compact desktop pattern generator allows you to test a range of different display devices ranging from HDMI/DVI-D capable monitors up to HD 3D Plasma, LCD TVs and projectors. Its capable of outputting a wide range of test patterns, screen resolutions and refresh rates. Ideal for use in testing environments, service departments, broadcasting and video production applications, it's also compatible with DVI-D capable displays when using a suitable adapter.
-
WIKA Alexander Wiegand SE & Co. KG
WIKA's robust and modular calibration systems are designed for checking the SF6 gas density and pressure measuring instruments. The test item is connected to the calibration system via an adapter and, by pressure generation with a hand pump, makes it possible to exactly approach the measuring points. A subsequent comparison of the displayed values of the test item and reference instrument allows assessing the instrument's suitability for on-site use. The instrument is always protected and ready for use with the robust service case and an additional foam insert.