Microwave Meters
Measure microwaves - electromagnetic waves having a wavelength from 300 mm to 10 mm (1 GHz to 30 GHz).
-
product
Single Phase Meter Test Bench
Supreme Instrument Laboratories
Single phase meter test bench suitable for calibration & testing of AC Ammeters, AC Volt Meters, AC Single phase Energy Meters, Power Factor Meters & Watt Meters. Other Technical Specifications are as under
-
product
1000A AC/DC Clamp Meter
CM84
The CM84 is a high specification 1000A clamp meter, packed full of functions for the installation, testing and maintenance of domestic and industrial installations. It is light enough for easy one handed operation but still robust enough for use in harsh environments.
This compact meter provides accurate measurement of AC voltage to 750V, DC voltage to 1000V and AC current to 1000A. It has the same test functions you would find on a high specification multimeter making this clamp a comprehensive testing solution for electricians, maintenance and service engineers. This has the added benefit of DC current measurement to 1000A and has a useful DC current zero function.
-
product
Meter With Conductivity/ATC Probe
CON 700
The economy Eutech CON 700 offers years of reliable, accurate and consistent performance. User-friendly features make the instrument an ideal research partner in laboratories, productions plants and schools.
-
product
5-in-1 Intelligent Cell Meter
#01444
Number of Cells: NiMH/NiCd: 4-7 cells; LiPo/Li-ion/LiFePO4: 1-7 cells
-
product
High Resistance Meters
Measurements International Ltd.
Direct or Substitution Measurements, Automatic and Manual Operation, No Temperature Coefficient, Multiple Modes of Operation.
-
product
20J3 SHEET RESISTANCE METER
Non-contact measurement of Ohms/sq, Ohms-cm, resistivity, thickness, and moreMeasures nearly all thin conductive materials or coatingsChoose a sensor in one of four ranges, from .005 Ohms/sq to 100,000 Ohms/sqadd other sensors laterFor benchtop or inline applicationsSimple one-button operationSmall footprint with detached sensor probeOptions include vacuum-ready probe, PC-based productivity software, Ethernet connectivity, stage, and more
-
product
CWDM Optical Power Meter
JW3226A
Shanghai Joinwit Optoelectronic Tech,co.,Ltd
JW3226A CWDM Power Meter is specially designed for CWDM system, covering wavelength from 1270~1610nm.It measures and monitors optical power and attenuation value of 18 channels from wavelength 1270nm to 1610nm wavelength.
-
product
High-Power Detector Laser Power Meters
11PMK-W5
11PMK-W5 power detectors surface absorber stands up to average power densities of 100 kW/cm². That is the best in the world for average power density. 11PMK-W5 high-power detectors come ready to mount on a rod, a bracket and the square case even lets you set them right on the optical table.
-
product
4 2/3 Digital Resistance Meter
CS2-RS
CS2-RS Resistance Indicator has been designed with high accuracy measurement, display and communication of Ohm (2 wire) as like as Coil of motor or transformer.The meter supports Field Calibration function. It can be calibrated with sensor (Resistance) to meet machinery structure.We build flexible function as like as 3 bank (for multi-range scaling and set point) and 3 external control inputs meet to various testing equipment inquiry.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipments applications.
-
product
Turbidity Meters
Turbidity meters are needed in order to conveniently test the quality of various different areas of water that can be drinking water, including food processing and beverage manufacturing and many applications where fluid clarity is crucial.
-
product
Handheld Water Quality Meters
LAQUA EC210
- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Automatic / manual temperature compensation and temperature calibration function- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- °C & °F temperature readings- Auto log data; built-in memory can store up to 500 data - Auto stable, auto hold, and real-time measurement modes- Auto shut-off (programmable: up to 30 minutes)- Monochrome LCD with white LED backlight: 50 x 50 mm- Powered by 2 x AA batteries - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Packaged with electrode and calibration solutions in carrying case- 3 years meter warranty
-
product
RF And Microwave Accessory Kit
N9311X
N9311X RF and Microwave Accessory Kit complements Keysight's low-cost handheld and benchtop solutions. These accessories provide you with a complete solution when using Keysight handheld and low-cost benchtop solutions for your measurement needs.
-
product
Clamp Meters
Rishabh Instruments Pvt. Ltd.,
Measures, calculates and displays power parameters of single phase or three phase systems. It features bluetooth communication with Android Mobile App. and software for PC for Data Logging, report Generation & Analysis
-
product
Digital Sound Level Meter
732A
Whether you are testing for OSHA compliance, quieting equipment, or monitoring the roar of a stadium crowd, B&K Precision's Sound Level Meters can get the job done. The model 732A Sound Level Meter provides 30~130 dB capability in three convenient measurement ranges Low, Med and Hi with an accuracy of ±1.5 dB. The meter meets the IEC 651 Type II and includes frequency weighting A & C and fast and slow time weighting.
-
product
Infrared / UV Power Meter
In consideration of ergonomics, this mini optical power meter with its compact,portable and easy operating features is specially designed for pros who amount,maintain the fiber optic network. This unit is widely applied with its 6 wave length selection.
-
product
Meter With pH Electrode, ATC Probe
ION 2700
Intuitive, self-diagnostic and flexible with advanced set-up options for user-customization, the Eutech ION 2700 series comes with a large, one-glance-sees-all screen. View pH, ION or Redox reading together with temperature, electrode status, calibration points, date and time all at once!
-
product
Gas Meters
A specialized flow meter, used to measure the volume of fuel gases such as natural gas and liquefied petroleum gas.
-
product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 18GHz, 50Ω, SMA
40-784B-022
The 40-784B-022 (PXI) and 42-784B-022 (PXIe) are dual SP6T 18GHz unterminated microwave multiplexers. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
product
Meter Socket Logger
PM2000
The PM2000 Meter Logger (USA only) is a 5-channel data logging system built into an electric meter housing. It is ideal for responding to residential voltage complaints and power consumption problems.
-
product
Scanning Head For Energy Meter Test
PACB108
PACB08 is the accessory device to perform the energy meter test, which can work together with PONOVO’s relay test sets to test energy meter by using Energy Meter Module in Powertest software.
-
product
LED Car Audio Meters
VM-1 (For 12V systems)
*White LED Backlight*Mil spec FR4 circuit board*Regulated power supply*Constant LED current and brightness regardless of battery voltage (won’t dim with your beat)*20 bright surface mount LEDs*Designed for 12 Volt Systems
-
product
Clamp Meters
TES Electrical Electronic Corp.
Variable Frequency drive measurement. LoZ voltage measurement to drain ghost voltages. Check 3phase sequence. True RMS reading on AC and DC+AC mode. Inrush current measurement. A measurement for HAVAC flam sensors.
-
product
Clamp Meters
oltage DC 600V with basic accuracy ±(0.5%+5d)Voltage AC 600V with basic accuracy ±(0.8%+5d)Current AC 400V with basic accuracy ±(2.50%+6d)Slimline Electric Clamp Meter Resistance 20M ohms with basic accuracy ±(1.0%+4d)Continuity buzzer sound at 300 ohmsDiode test current 0.3mA; Open circuit voltage 1.5VAccessories: test leads, carrying case, 2(AAA) 1.5V batteriesSize:8-1/16"L x 2-3/4"W x 1-1/2"HSlimline Electric Clamp Meter Weight: 7oz.2000 LCD display countsDecimal Point ReadingsDisplay with backlightData holdMax holdAuto power offLow battery indication
-
product
PXI/PXIe Microwave Relay, Dual SPDT, 18GHz, 50Ω, SMA
40-780B-522
The 40-780B-522 (PXI) and 42-780B-522 (PXIe) are dual SPDT 18GHz unterminated microwave relay modules. The 40/42-780B range is available with one, two, three or four SPDT switches capable of switching frequencies up to 67GHz in 50Ω or 2.5GHz in 75Ω. Connections are made via front panel mounted high quality RF coaxial connectors, SMA or N-Type for 50Ω and 1.6/5.6 in 75Ω versions. Remote versions are also available which can support up to three SPDT relays in a single slot.
-
product
Portable Electricity Meter Testers
EE-120A-3S
The EE-120A-3S unit consists of a three-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types of electricity meters using the voltages of the network. The meter error can be measured for active, reactive or apparent energy in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Maximum Demand Test, Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the three-phase network – with direct measurement or with optional current clamps.
-
product
Electro Magnetic Flow Meter With Remote Display
MFI-013
Aarohi Embedded Systems Pvt. Ltd
MFI-013 electromagnetic flow meter is manufactured with state of the art technology. Micro controller based design provide precise measurement. A magnetic flow meter (mag meter, electromagnetic flow meter) is a transducer that measures fluid flow by the voltage induced across the liquid by its flow through a magnetic field.The physical principle at work is electromagnetic induction.
-
product
LXI Microwave Multiplexer, SP4T, 3-Bank, 50GHz, 50Ω, SMA-2.4
60-803-703
Our 60-803-703 is a 3 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 50GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
Microwave Wideband APD-TIA Receivers
MR12 (40KHz~18GHz)
Hangzhou Huatai Optic Tech. Co., Ltd.
MR12 series microwave wideband optical receiver, adopts high Sensitivity APD diode and limiting amplifier, within bandwidth of 40KHz~18GHz, they are featured with excellent linearity, high responsibility and superior flatness of the RF response in both, power and phase. They provide an outstanding linearity fiber optical communication for analogue wideband microwave application. Due to avoidance of using expensive coaxial cable or wave-guide, there will be no limitation in transmission distance, which improves the signal quality and reliability of the microwave communication. They can be widely applied in microwave communication system such as remote wireless, timing and reference signal distribution, telemetry, measurement and delay line etc as well as 10Gb/s high speed communication system.
-
product
3.5 Digit Handheld Clamp Meters
U1210 Series
Measurements of electrical distribution cables can be challenging and risky. For cables up to 2 inches in diameter, the Keysight U1210 Series (U1211A, U1212A, U1213A) handheld amp clamp meters (also known as clamp-on ammeters) enable high-current measurements without breaking the circuit. Plus, they provide an extra layer of protection with CAT IV 600 V and CAT III 1000 V safety ratings and include full digital multimeter (DMM) measurement features.