Calibrators
ascertain instrument graduation deviation and rectify to precision known values.
See Also: Calibration, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
Product
ISA Bus Dual Redundant MIL-STD-1553 A/B Simulator / Analyzer / Tester
CIC101-4
-
Price: Request QuoteMIL-STD-1553 A, B Simulator/Analyzer/Tester ISA BUS Interface Card. The CIC101 can be used for Validation Testing,Production Testing, full bus simulation and monitoring, as ageneral purpose 1553 interface or a stand alone bus Analyzer. It provides precise message scheduling andmeasurements. Major and minor frame times areindependent of message sequences or retransmissions onerrors. The start of all command messages may be set to beindependent of message length, response time or length ofresponse. The CIC101 features a calibrated Message timingand low jitter RT responses.
-
Product
Chlorophyll Concentration
-
Linear OutputThe Apogee chlorophyll concentration meter is calibrated to measure chlorophyll concentration in leaves with units of mol of chlorophyll per m2. This eliminates the problems with relative indexes of chlorophyll concentration.For reference and comparison purposes, the Apogee meter also outputs relative units [CCI or SPAD] if desired.For details see: Parry, C., Blonquist Jr., J.M., & Bugbee, B. 2014. In situ measurement of leaf chlorophyll concentration: analysis of the optical/absolute relationship. Plant, Cell and Environment 37:2508-2502.
-
Product
PXI Strain Gauge Simulator Module 2-Channel, 1K
40-265-202
Strain Gauge Simulator
The 40-265 is a strain gauge simulator that simulates the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. It provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance that is easy to calibrate and use.
-
Product
Low Phase Noise Reference Source
96270A
-
The 96270A RF Reference Source is the simplest, most accurate and cost-effective single instrument for calibrating spectrum analyzers and RF power sensors and more, up to 27 GHz.
-
Product
Universal OTP Functional Test System for the Production of Level and Fluid Sensors
Functional Test
Multifunctional function tester with parallel test function based on the LXinstruments OTP2 system platform. The system is used for assembly, final test and calibration of liquid and level sensors for commercial vehicles, construction machinery and shipbuilding in a high mix / medium volume environment.
-
Product
ACCUplace Position Grid
AP-P Series
-
The AP-P is a unique calibration target that is designed to test the position and/or recognition ability of a vision system. The matrix of small scales, precisely positioned in a grid matrix format, makes testing for subject recognition and system positioning simple.The overall target is comprised of a matrix consisting of 6.0mm x 6.0mm square individual components each having a 5.0mm x 5.0mm X & Y Scale with 0.100 divisions. The scale has pitch accuracy of 1μm. The AP-P is available on two standard materials; Chrome on Glass (CG) and Chrome on Opal (OP).
-
Product
Calibration Kit
N1.2
-
*N1.2 Calibration Kit, * Frequency Range: up to 1.5 GHz, Impedance: 50 Ohm, * Connector Type: N-type.
-
Product
Switch Amp
-
One of many potential designs, Teledyne RF & Microwave's switched amplifier covers 100 to 2000 MHz, providing 18 dB gain, phase matched to within ±1.0 degree. The primary RF input and a secondary calibration signal input are switched, then amplified, and split to two outputs. Gain balance between any of the two outputs is ± 0.5 dB. Output power at 1 dB compression is +14 dBm and input/output VSWR is 2.0:1 maximum.
-
Product
High Voltage Pulse Attenuators
-
Barth High Voltage Pulse Attenuators are matched impedance coaxial attenuators for use primarily in pulsed 50 ohm systems, or where occasional transients would damage ordinary units. The attenuator design closely matches the impedance around each resistor, to that resistor. These attenuators feature an input impedance very close to 50 ohms, with characteristics as good or better than most microwave attenuators. These units are ideal for use in nuclear and high energy experiments. Extensive testing during manufacturing insures very high reliability for single-shot experiments. A voltage coefficient of the resistive film of less than .0001 %/V allows low voltage calibration of most systems.
-
Product
MIPI Receiver Test Solution
M8085A
-
The M8085A is a software plug-in for M8070A Bit Error Ratio Test system software within the M8000 series of BER test solutions. The M8085A software plug-in controls either the M8190A or the M8195A Arbitrary Waveform Generators to create C-PHY or D-PHY standard compliant test signals. In addition it provides routines for calibration of all signal parameters and for all tests specified in the applicable Conformance Test Suite. Together with the additional available DUT control interface it is possible to read the BER of the receiver under test from the M8070A software and display the BER dependency from test parameters within the M8070A user interface.
-
Product
Humidity
-
ACI humidity sensors are durable, accurate, reliable, and backed by a five-year warranty on the entire device. They can be field calibrated to reduce operating costs and paired with a temperature sensor(s) to reduce installation costs.
-
Product
PCI Strain Gauge Simulator Card, 2-Channel, 1k
50-265-202
Strain Gauge Simulator
These cards simulates the operation of a range of strain gauges making them ideal for testing strain gauge meters and a wide variety of industrial control systems. They provide a simple way of replacing in house developed sensors with a low cost simulator having excellent performance that is easy to calibrate and use.
-
Product
Four Channel Load Cell Tester
LCIC-4HS
-
Industrial Measurement Systems Ltd.
Four Channel Load Cell Interface Card Model LCIC-4HS The LCIC-4HS is a four channel load-cell interface board for the IBM PC/AT and compatible computers (ISA Bus). This board was especially designed to fit very fast and real-time weighing applications such as multi-head fillers. It supports up to four channels with one load-cell on each. All the necessary filters and the batching control functions are built on the board and are easily accessible by the user. Direct communication with the PC bus and high-frequency sampling enables the LCIC-4HS to handle all real-time applications and to achieve very high accuracy. The LCIC-4HS is memory-mapped. Up to 32 boards (128 channels) may be installed in a single PC. It comes with a detailed user manual and software utilities for easy installation and calibration as well as full examples for the programmer (including Win 95/98 drivers).
-
Product
MPI Testing Solution
-
Since 2008, MPI’s LED tester has provided optical and electrical measurements. With mass production experience, tester functions include flexible recipe management, accurate calibration, and statistical analysis. Flexible configurations allow the customer to choose test equipment configurations from the spectrum meter, photo detector and source measurement unit in accordance with your specific requirements. With accurate controlling of each instrument and intelligent data analysis, our testers offer the most accurate measurement result for a wide variety of optical devices.
-
Product
Frequency Calibrator
VCH-313
-
The frequency calibrator VCH-313 is designed to determine the frequency error and calibrate frequency standards of various types based on the signals of the NSC SNS GLONASS/GPS .
-
Product
High Line Pressure Variable Reluctance Pressure Sensor to 10,000 psid
DP360/DP363
-
The DP360 can be calibrated for a full scale as low as ±50 psid while withstanding high static line pressure. Low differential pressure may be measured at static pressures as high as 10,000 psig with a maximum 3% FS zero shift error.
-
Product
GFS Primary Gravimetric Flow Standard
-
The GFS dynamic gravimetric mass flow calibration system allows users to maintain the accuracy and traceability of molblocs or other high precision devices using the same primary reference used by Fluke Calibration. GFS is a true mass flow reference suitable for use in premier measurement institutes who require the lowest measurement uncertainty.
-
Product
IEC Standard Burden Sets (Current)
IEC Burden Sets
-
Testing and calibrating current transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. These burden sets have been carefully designed to meet these requirements. They also provide the standard burdens required for the testing of current transformers for metering service, and for the testing (within the current rating provided by the sets) of current transformers for relaying applications, all as called for by IEC (International Electrotechnical Commission) Publication 185: 1987.
-
Product
NanoCD Standards (NCD)
-
The NanoCD™ (NCD) is the first commercially available standard to provide line width accuracy calibration at the 45 nm, 65 nm, 90 nm and 130 nm nodes. Use these standards for tool matching, calibrating the width of a CD-AFM tip, or CD-SEM diagnostics.
-
Product
Trace Level Chemiluminescence NO-NOy Analyzer
Model T200U NOY
-
Teledyne Advanced Pollution Instrumentation
The Model T200U NOy analyzer has been developed and refined specifically to address the challenges of NOy monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is coupled with a remote NOy converter via umbilical to allow measurements with a lower detectable limit of 50 ppt.The Model T200U NOy analyzer combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer. The remote NOy converter is provided with a stainless steel, NEMA 4X (IP65) enclosure and custom sample umbilical to allow a mounting height of 10 meters. In addition, the converter features a unique purge circuit designed to remove residual calibration gas.
-
Product
Calibration Services
-
Trescal US is accredited to ISO/IEC 17025, ANSI/NCSL Z450-1 and ANSI/NCSL Z540.3 through A2LA. Trescal has one of the largest scopes of accreditation in the country for electronic, physical and dimensional domains as well as being a factory-authorized service center for many International manufacturers.
-
Product
Testwave Calibration
-
Testwave® LLC calibrates electronic, physical, & dimensional test equipment. Our Sparks facility includes a state-of-the-art temperature controlled calibration laboratory, which holds the temperature to within +/- 0.5°C. We send you recall notices before your equipment calibration expires, and if we don’t hear from you, we will call, to make sure you stay in compliance with your calibration requirements. Calibrations are performed at your facility, or at our Sparks Nevada laboratory.
-
Product
Cable Length Meters
CLM-1000
-
*Measures these AWG wire gages: 18, 16, 14, 12, 10, 8, 6,4, 2 , 1/0, 2/0, 3/0, 4/0*Measures these kcmil wire sizes: 250, 350, 400, 500, 600, 750, 1000*Eight user-programmable settings for other gages*Powered by (6) 1.5V AA batteries*Replacement calibration rods (pair) available as CLM-ROD, UPC 02721*Replacement Kelvin clips (pair) available as CLM-CLIPS, UPC 02722*Feet
-
Product
Gas Measurement Device
Gascoseeker 2-500
-
Teledyne Gas & Flame Detection
Built on the success of the robust and reliable Gascoseeker MK2, the Gascoseeker 2-500 is the UK gas industry standard instrument for measuring % LEL and % volume flammable hydrocarbons, with over 20,000 instruments in use in the UK gas industry.The two-button operation means the Gascoseeker 2-500 is easy to use and operator training can be conducted quickly. The rugged design allows the Gascoseeker 2-500 to be used in harsh environments. The Gascoseeker 2-500 is also fully compatible with our range of calibration software and equipment.
-
Product
Individual UPC Bar Code Standards
-
The UPC Verification Calibration standards are a unique set of symbols that assures an exact and reliable primary bar code standard exists for UPC codes based on ANSI X3.182/ISO 15416 methodology. These standards assures that manufactures of verification equipment, scanners, QC labs and end users now have an accurate basis for checking the measurement capabilities of their equipment. These standards are intended as a fundamental calibration tool for an QC program, providing a continuous scale from best to worse case characteristics of each parameter. With complete NIST traceable data supplied, it is ideally suited to those requiring traceability, such as ISO certification. Each symbol is individually calibrated to ANSI X3.182/ISO 15416 standards using a custom built microdensitometer. These cards are supplied calibrated for use with a 6 mil scan aperture and 660nm wavelength. (calibration wit other aperture sizes or wavelengths is available)
-
Product
PXI RTD Simulator Module 6-Channel PT100
40-262-101
Simulator
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
Product
Gasmet Calibrator
-
Gasmet portable calibrator is one of the most important tools in generating new applications for the Gasmet FTIR gas analyzer. The calibrator incorporates a syringe pump, a manual needle valve, a mass flow meter, and a stainless-steel injection chamber. The syringe pump injects precise amounts of liquid or gas into a hot nitrogen gas flow, thus producing a continuous flow of a known concentration calibration gas.
-
Product
CALKIT
612 IBT
-
This CALKIT enables you to recalibrate your ACT 612 Intelligent Battery Tester. Each CALKIT consists of replacement calibrated plug-in test leads, new replacement labels and instructions.
-
Product
pHTestr® 50 Waterproof Pocket pH Tester,
Premium 50 Series
-
The Oakton pHTestr 50 has a replaceable double junction sensor for longer life, an expanded number of applications, and easy maintenance. Double-junction electrode sensor handles wastewater and solutions containing sulfides, heavy metals, and TRIS. Electrode sensor offers a clog-resistant Kynar® junction and a recessed, glass pH bulb to protect against breakage. Valox sensor housing resists most chemicals. The keypad clicks to confirm operation, and allows access to a variety of functions. Calibrate up to three pH points with the auto-buffer recognition at both USA and NIST standard buffers. Additional features include an automatic temperature compensation (ATC), hold function, auto-off function, self-diagnostic error messages, and a three-segment battery-life indicator.
-
Product
Humidity calibration with humidity calibrator
HUMOR 20
-
The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. The humidity calibrator HUMOR 20 developed by E+E is the ideal reference instrument for these requirements and is traceable to international standards. The HUMOR 20 can be used in the humidity range of 10-95% RH both for monitoring cylindrical sensors and also for monitoring instruments with cubic dimensions.





























