Current Transformers
transfers accurately proportional levels of current to multiple circuits.
-
Product
Instrument Transformer Test Systems
-
Our systems for testing voltage (VT) and current (CT) instrument transformers are conceived among other things for testing accuracy and insulation.
-
Product
Transformer Turn Ratio Instrument
ART-3D
-
The ART-3D is high precision instrument designed to measure ratios, magnetization currents, phase-shifting in power transformers, distribution transformers, potential and current transformers, in conformity to IEEE C57.12.90 and CEI/IEC 60076.
-
Product
Surge Tester (Impulse Winding Tester)
SS6815 / SS6815F
-
Surge testers (impulse winding tester) is used for testing and check the insulation grade of turns between turns, insulation grade of layers between layers, insulation grade of windings between turns. It is used widely for transformer, current sensor, voltage sensor, relay, contactor, inductor, motor, generator, valve coil, voice coil, etc.
-
Product
Current Transformers
-
National Meter Industries Inc.
Is an instrument transformer, used along with measuring or protective devices, in which the secondary current is proportional to the primary current (under normal conditions of operation) and differs from it by an angle that is approximately zero.
-
Product
Split type AC Current Transformer
CTS-200
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*1A output for metering application.*Short circuit switch for secondary output is provided for safe operation.*High accurate transformer for the application of first class meter.*Easy installation by metal fitting.
-
Product
Primary Injection Kit
Prima Series
-
Prima Series is designed for Primary Current Injection Testing of Current Transformers, Protection Relays & Circuit Breakers during their Factory Test, Commissioning and Routine Testing.
-
Product
Current Transformer
-
Nippen Electrical Instruments Co.
DIGITAL METERS NIPPEN electronic energy meters are panel mounting type innovative energy monitoring devices ,having state of the art electronic microcontroller circuitry for reliability and accuracy. They can be used for 1Ø / 3Ø balanced and unbalanced loads.
-
Product
Test Switches and Accessories
-
Test switches are designed and manufactured to allow quick and easy multi-circuit testing of switchboard relays, meters and instruments by any conventional system.These test switches and related test plugs have the features necessary for applications involving the measurement of individual currents and voltages associated with substation instrumentation and protection devices. They have been especially designed for the measurement of potential elements, current elements, and make-before-break short-circuit elements related to Current Transformer (CT) circuits.
-
Product
Primary Current Injection Testers
-
Primary current injection tests are carried out during commissioning and certification of various types of switchgear and current transformers (CT), as well as during diagnostics of grounding circuits, testing circuit breakers and other devices. Primary current injection testers can also be used for determining the terminals polarity and transformation ratio of current transformers, thermal testing of electrical devices, testing automatic reclosers and sectional disconnectors.
-
Product
Real-Time Online Monitoring to Detect and Analyze Potential Partial Discharge (PD) Signals and Insulation Faults using UHF, AE, and HFCT
PDMonitor
-
Power Monitoring and Diagnostic Technology Ltd.
The PDMonitor, which utilizes Ultra High Frequency (UHF), Acoustic Emission (AE) and High Frequency Current Transformer (HFCT) sensors and is designed to conduct real time online monitoring to detect and analyze potential Partial Discharge (PD) signals and insulation faults before they lead to breakdown or catastrophic failure in power assets. The system provides the developing trend of the PD, when occurring, as alarms in real time, thus helping to predict the insulation degradation status of the asset, prevent sudden accidents, and provide an effective database for Condition-Based Maintenance (CBM) of power assets.
-
Product
H/L Voltage Clamp Meters
-
High Voltage Current Transformation Ratio Tester breaks traditional structure, specially designed for high and low voltage first and secondary loop current, variable ratio, and current leakage test; apply the latest CT technology and mask digital integration technology, composed of special high-voltage clamp, low voltage clamp, host, high voltage insulation rod and monitoring software, etc; its wireless transmission test data can penetrate multiple building obstacles with a straight-line distance of 30 meters.
-
Product
MCB Magnetic (Instantaneous) Trip Test Bench
-
The test bench is specially built for low voltage- B, C & D curve MCBs. Specially designed custom built jigs are able to accommodate single, double, three and four pole MCBs. Decades of experience has helped us to design current source (transformer) in a special way such that good current regulation and high accuracy is ensured with a variable range without the use of any variable transformer in the system. The product is better than the competition with conventional technology at a lesser price!
-
Product
High Frequency Transformers
-
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
Product
Split type AC Current Transformer
CTS-100
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*1A output for metering application.*Short circuit switch for secondary output is provided for safe operation.*High accurate transformer for the application of first class meter.*Easy installation by metal fitting.
-
Product
Toroid Core Coil Turns Testers
SS107A
-
The magnetic torrid ring core winding coil turns tester (SS107A) adopts the high speed center microprocessing unit circuits and precise measurement A/D circuits. This coil turns tester is used to count the coil turns of various torrid core winding coils. Like as: torrid core inductors, torrid core transformers, torrid core sensors, wate meter sensors, torrid current transformers, torrid core choke coils, etc. The tone tester is named magnetic ring core coil turn tester also.
-
Product
Auxiliary Current Transformers
-
Osborne Auxiliary Current Transformers are often used to reduce system currents to lower values appropriate for instrumentation and/or protection circuits. The Aux CT’s are designed for specific current ratios and burden impedance with a known transformation error. Osborne’s units are built for high performance and longevity in the most demanding environments.
-
Product
Current Transformer
LTTJ
-
Love Controls LTTJ Series Current Transformers allow easy monitoring of the current flowing to your load. This easy to use device provides a 0 to 10 VDC signal into both low and high impedance circuits, and is easily scalable to your needs
-
Product
Power Factor Correction
HV/MV
-
Power Capacitors for medium voltage network:Ducati Energia proposal includes range of single and three-phase capacitors up to 800 kVAr with max HSV of 36kV.Upon request,we provide them with internal fuses stainless steel cases,inrush reactors,expulsion fuses as well.System is designed according to the specific application and it is composed by current transformers (CT),voltage transformers (VT) and relais.
-
Product
Transformer Turns Ratio Tester
CX-BY
-
Shenzhen Chuangxin Instruments Co., Ltd.
It is to test voltage ratio, vector, polarity, ratio error of current transformer and voltage transformer.
-
Product
400/5A CHEAP SPLIT CORE CAST RESIN CURRENT TRANSFORMER
LZCK310-10
-
Beijing GFUVE Electronics Co.,Ltd.
LZCK series outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the characteristics of Small magnetic circuit loss and can be split, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case(ABS or PC) which is flame retardance anti-moisture, stable performance, no maintenance.
-
Product
Instrument Transformers Tester
TE30
-
Calmet Smart Calibration Devices
Electricity meters tester class 0.05 and 0.1. Three phase tester of current transformers and analyser of power network quality. It makes possible electricity meters testing on the site or in the laboratory.
-
Product
Primary Current Injection Testers
-
Primary Current Injection Tester is designed for testing protective relay and circuit breakers and also testing the turns ratio of current transformers at high variable currents. A test current is injected into the primary side of a system to determine how the system behaves at particular levels of current. This test makes it possible to determine whether the relay will trip and how long the current needs to flow before the trip is initiated.
-
Product
Single-phase Electricity Meters
-
Single-phase static electricity meters AMS B1x-SAx are determined for direct and indirect measurement of active energy displaying value on mechanical register with stepping motor. In the case of CT (current transformer) operated meters (x/5A) it is necessary value of register to multiply by the current transformer ratio.
-
Product
Brute Hight Current Probes
P4301
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Brute High Current Probe
P4301-1R
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Brute High Current Probe
P4301-2F
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Godzilla High Current Probe, 100 Amp
HC375
High Current Probe
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
Product
NI-9203, 200 kS/s, ±20 mA, 8-Channel C Series Current Input Module
783731-01
Current Input Module
200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 … includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.
-
Product
NI-9227, 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module
781099-02
Current Input Module
50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module - The NI‑9227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications. It includes built-in anti-aliasing filters. When used with a C Series Voltage Input Module, the NI‑9227 can measure power and energy consumption for applications such as appliance and electronic device test. You can not only measure and meter current and power but also look at quality factors such as noise, frequency, and harmonics.
-
Product
Brute High Current Probe
P4301-1Z
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45