Filter Results By:

Products

Applications

Manufacturers

EMC

equipments, immunity from or emissions amicability of EMI. AKA: Electromagnetic Compatability

See Also: EMC Analyzers, EMC Probes, EMC Software, EMC Testing Services, EMC Test, Immunity, EMI


Showing results: 286 - 300 of 350 items found.

  • Line Impedance Stabilization Networks

    LISN - Com-Power Corporation

    LISN stands for 'Line Impedance Stabilization Network'. Com-Power offers a line of LISNs developed for conducted emission testing according to the most commonly adopted EMC specifications like CISPR, FCC, ISO, EN, RTCA DO-160 and MIL-STD 461D. The LISN circuit is designed and constructed to meet the performance criteria given by these standards.

  • Dual-ridge Horn Antenna 1 to 18 GHz

    EH118 - MVG EMC

    EH118, a dual-ridge horn antenna that will operate from 1 to 18 GHz. This antenna has a balanced, smooth antenna factor curve that extends all the way to 18 GHz, a reduction of higher order modes on the aperture, and low return loss (SVSWR). The EH118 is applicable for commercial, military and automotive test standards and will include applicable calibrations. The EMC dual-ridge horn antenna offers these key features: single linear polarization, smooth/balanced gain with frequency, low return loss /VSWR, and ultrawide bandwidth (18:1).

  • Near Field Probes

    Com-Power Corporation

    A typical emi emission test is performed using broadband EMC antennas such as biconical, log periodics, Combilogs and horns. These antennas usually placed at 1, 3 or 10 meter distance as required by the test specification. These is considered far field measurements and the emission limits are given for the specific distance by the specification. During EMI compliance measurements, the emissions levels from products are compared with these limits. If the product exceeds these limits it is considered failing. These tests are typically conducted in a open area test site IOATS) or inside an anechoic chamber.

  • Antenna Masts

    innco systems GmbH

    Antenna Masts are an integral part of EMC and RF measurement systems. Innco system masts are renowned worldwide as the standard benchmark. Available in manual or automatic, using either pneumatic and or electric driven, the antenna mast design has the capacity to carry antennas of 6kg (MM) and 10kgs (MA) as standard. Higher loads are available upon request.

  • RF Amplifiers up to 1000 MHz

    Empower RF Systems, Inc.

    Narrow and Broad band high power RF modules and rack mount amplifier systems using solid state devices including LDMOS and GaAs in Class A and Class A/B topologies for Pulse, AM, FM, continuous wave and digital modulation applications that include EW, Radar, Jamming, EMI and EMC radiated immunity, and wireless communications testing.

  • Spectrum Analyzer

    WaVue™ - Consultix

    RF Spectrum Analyzer is an invaluable tool for the test, design and maintenance of radio frequency signals, circuitry and equipment.Engineers have been widely using spectrum analyzers to measure frequency response, noise, and distortion characteristics of all kind of radio frequency circuitry. Also in EMC testing, wireless spectrum analyzer is used for basic pre-compliance testing.

  • MP CI set

    Langer EMV-Technik GmbH

    The MP CI set up to measure coupling impedance is used to determine EMC characteristics of connectors and cables. The coupling inductivity defines the coupling inductance of external disturbance on the shield or on the ground with the desired signals. If the coupling inductivity is considered in the construction set-up and the pin or wire assignment of connectors or cables, then the connectors or cables will be more interference-resistant. The MP CI set-up for measuring coupling impedance can be used for following measurements at connectors or cables: 1. measurement of a single signal (common mode) 2. measurement of a symmetrical signal (common mode) 3. measurement of a symmetrical signal (differential mode)

  • Voltage Variation Simulator

    KES7400A - Kikusui Electronics Corp.

    The KES7400A Series comes in a single cabinet that consists of a Signal Generator module (including an arbitrary pulse generator), which combines our power supply technology and EMC technology, and a high-speed bipolar power supply module. Many automotive electronic devices have long wire harnesses and inductive load characteristics, as do motors, or capacitive load characteristics with a large-capacity capacitor connected between the input and ground. In the case of these devices, general DC power supplies exceed the linear operation range, potentially making it impossible to obtain the desired waveform output.

  • Medical Device Testing and Evaluation

    Washington Laboratories LTD.

    Medical devices are subject to many regulatory standards from general requirements for basic safety and essential performance (60601-1) with inclusion of several collateral standards dealing with operational characteristics (e.g. 60601-1-2 for EMC; 60601-1-11 for home medical, etc.) and vertical standards dealing with specific aspects of the device (particular standards often referred to as -2 standards). Test and evaluation of the applicable requirements stem from Edition 3 (currently in effect for most regions) with a risk based review to assess applicability of the standard and to identify areas not covered by the standards.

  • FCC Testing & Certification

    F-Squared Laboratories

    F2 Labs can provide you with Federal Communications Commission (FCC) Certification in our EMC Testing Lab, Supplier’s Declaration of Conformity (SDoC), formerly Verification and Declaration of Conformity, testing. Manufacturers who sell electrical and/or digital products in the United States must have their products tested by an accredited lab certified by the FCC. F2 Labs is accredited by the FCC as a Conformity Assessment Body (CAB). We partner with a Telecommunication Certification Body (TCB) in order to provide our clients with FCC Part 15 certification and compliance testing & approvals.

  • Pre-compliance Testing

    Silent Solutions LLC

    SILENT offers pre-compliance testing for products with planned distribution to commercial and industrial markets in the US and overseas. This includes testing to ensure that emissions, immunity, and circuit-to-circuit interference problems are discovered early and immediately brought under control. We use the most advanced EMC and RF test & measurement equipment and diagnostic software available from leading suppliers.

  • Transient Limiters

    Com-Power Corporation

    Transient limiter LIT-153A and LIT-930A protects a spectrum analyzer input from high-level transients from the line impedance stabilization networks during EMC conducted emissions testing. It has a combined frequency range of 9 kHz to 30 MHz. The built in high pass filter helps reduce 50/60 Hz line feed through. (see application notes)

  • ESD Generators

    Hilo Test

    The ESD Simulators ESD suitable for performing EMC tests of systems and equipment according to the standards IEC / EN 61000-4-2 and ISO / TR 10605. It can far beyond the standard boundaries higher test levels are adjusted. Depending on the device under test and the test setup are two test method shall be: Air discharge (AIR) and contact discharge (CON).

  • High-end Transmission Electron Microscope

    CryoARM - JEOL Ltd.

    JEOL announces the latest member in its family of high-end transmission electron microscopes, the CryoARM. This highly automated TEM is designed for unattended operation and high throughput imaging of cryo-EM specimens. The CryoARM was initially introduced to a select audience at the 2016 Gordon Research Conference in Hong Kong, M&M 2016 in Columbus, OH and EMC 2016 in Lyon, France. The CryoARM is a dedicated cryo-TEM, based on the highly successful JEOL ARM (Atomic Resolution Microscope) series, an ultrahigh performance, highly stable platform considered to be the "best-in-class" TEMs. The development of the CryoARM was accomplished in collaboration with leading Life Science researchers.

  • Instrumentation HPAs

    Communications & Power Industries

    CPI SMP Division provides a complete line of high-powered continuous wave (CW) and pulsed instrumentation amplifiers for EMC testing, available in octave and multi-octave bandwidths from 1.0 GHz to 95.0 GHz and power levels exceeding 2.0 kW to meet the new military and automotive standards. CPI is the only supplier that manufactures both the traveling wave tube (TWT) and the TWT amplifier.

Get Help