Rubidium Frequency Standards
See Also: Rubidium Standards
-
product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-W
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
product
Primary Standard Capacitors
GenRad 1404 Series
The GenRad 1404 Series standard capacitors are the standard of choice in metrology labs, and still used today by standards bodies around the world. These capacitors have been designed as primary reference standards of capacitance with which working standards can be compared.
-
product
Reflectance Standards
Diffuse reflectance calibration standards in white or different grey levels. Traceable calibration for the wavelength range from 250 nm to 2450 nm.
-
product
Frequency Extenders
A frequency extender is an electronic device that allows high-fidelity analog audio to be sent over regular POTS telephone lines, without the loss of higher audio frequencies. It is an extended concept of a telephone hybrid.
-
product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
product
Standard Current Transformer
HL / 640
Wuhan Huatian Electric Power Automation Co., Ltd.
It is used as the calibration standard of current transformer in the error test of transformer.
-
product
Standard 1.50 (42.00) - 3.30 (94.00) General Purpose Probe
P2663G-1W1S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
product
Frequency Large Display Indicator
Signals & Systems India Private Limited
Large Display indicator measures and displays frequency from the input like supply voltage, 4-20mA and data received from other equipment. It meets high accuracy of 0.1% to measure Frequency. The large display is for clear visibility of the frequency reading from long distance. It is equipped with high bright red color 7segment displays. These are commonly used in Power plants, Substations, Manufacturing units and Field environments to provide direct frequency measurements of various devices.
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25H-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62T1-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3G
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
AC Measurement Standard
5790B
The 5790B is a multi-purpose ac measurement and transfer standard designed for the most demanding calibration applications. It combines the accuracy you expect from a thermal transfer standard with the ease of use of a digital multimeter. Absolute ac voltage measurement uncertainties are as low as ± 24 ppm (one year, 23 °C ± 5 °C).
-
product
High Frequency Modules
Digital Signal Technology, Inc.
Modulators, frequency dividers, amplifiers, filters, etc.
-
product
WR5.1 Frequency Extension Solution, 140-220 GHz with VDI Extender Modules
CobaltFx 140 to 220 GHz
CobaltFx cost-effective millimeter wave frequency extension system allows you to build a scalable and affordable 5G testing solution.
-
product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62H-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3L5
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
HIGH FREQUENCY DC BIAS
6565 SERIES
The 6565 HF DC Bias Unit is intended to be used with a Wayne Kerr 6500 analyzer, either the 6500B Precision Impedance Analyzer or the 6500P HF LCR Meter. Its function is to provide a source of DC bias current through the Device Under Test (DUT) while the analyzer is making AC measurements. Each 6565 unit can provide up to 10 A of DC current, and up to six 6565 units can be connected in parallel to supply a maximum 60 A. A digital ammeter on the front panel allows the user to see the dc bias current value and an indicator LED shows when the bias current is enabled.
-
product
CANbus Controller Standard Interface
PCI360
The PCI360 CANbus controller PCI card is based on the SJA1000. The SJA1000 provides an interface to the popular CANbus that support both standard (11-bit) and extended (29-bit) identifier messages. LEDs provide diagnostics information.The CAN network is a serial communication protocol which efficiency supports distributed real-time control with a high level of reliability.
-
product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-F
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-8
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
product
350 MHz Universal Frequency Counter/Timer, 12 digits/s, 20 ps
53230A
The Keysight 53230A universal frequency counter/timer serves all your frequency and time interval measurement needs. In addition to the typical frequency and time interval measurements, continuous/gap-free measurements are available for basic modulation domain analysis. Optional burst measurement software is available. An optional microwave channel can be added to measure 6 or 15 GHz.
-
product
4-Port 9 GHz Analyzer, Frequency Extension Compatible
C4409
C4409 Vector Network Analyzer delivers industry-leading dynamic range and sweep speed, with all the features engineers have come to expect included standard in our software. This VNA is frequency extender compatible and is the anchor network analyzer for the CobaltFx frequency extender system.
-
product
Spectral Radiant Flux / Luminous Flux Calibration Standards
Standard lamps calibrated in luminous flux and spectral radiant flux. Versions with 2-Pi and 4-Pi emission characteristics. Traceable calibrations in the wavelength range from 200 nm to 2500 nm.
-
product
Oil Immersed Transfer Standard
esi SR1030 Series
The esi SR1030 transfer standards consist of 12 equal steps. These steps are available in increments of 1 (SR1030-1), 10 (SR1030-10), 100 (SR1030-100), 1k (SR1030-1k), 10k (SR1030-10k) and 100k (SR1030-100k). The esi SR1030 provides four-terminal connections for each step or for series and parallel combinations of these resistance steps using the optional Series-Parallel (SPC102), Parallel Compensation Networks (PC101) and shorting bars (SB103). This improves power dissipation, stability and errors due to variance in temperature. The esi SR1010 and esi SR1030 are used for the same applications and are alike in configuration. The esi SR1030 differs from the esi SR1010 in that it is specially sealed, and values below 100 k are filled with oil to improve changes due to thermal variations.
-
product
Multimeter Digital 1999 Counts Display with Holster with Capacitance Frequency
MY67
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Multimeter digital 1999 counts display with holster with capacitance Frequency MY67 V&A.
-
product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5B
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
product
Time & Frequency Distribution Amplifiers
Brandywine offers a wide range of high quality, state of the art signal timing distribution amplifiers, all with very low phase noise. These precision timing signal distribution amplifiers offer a variety of time and frequency signals and interface formats including IRIG A, IRIG B, Have Quick, 1PPS, as well as low phase noise reference frequencies. All of our distribution amplifiers feature dual inputs with automatic failover and multiple independently buffered outputs.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1J-4-S