-
product
Compact Low-Frequency Control Element
900-LFC
The 900-LFC Low-Frequency Control Element extends the response of mid-sized P.A. systems to 35 Hz, revealing the nuances of your mix, down to the deepest bass with total accuracy.
-
product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03B-006
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Dielectric VTE Rating (k VAC): 1Nominal Impedance (Ohms): 50Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
product
110 GHz Frequency Extender
N5293AX51
The N5293AX51 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Dust Caps, Opens
These coaxial dust caps are used for protective purposes, both from the environment & contaminants. Note: SMA, 2.92, 3.5mm dust caps are the same, as the threads are the same. Likewise, 2.4mm & 1.85mm dust caps are the same, the threads being the same. Some people use opens for calibration purposes at low frequencies, but these opens are not VNA rated, we don't measure fringing capacitance etc.
-
product
120 GHz Frequency Extender
N5295AX51
The N5295AX51 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
product
350 MHz Universal Frequency Counter/Timer, 12 digits/s, 100 ps
53220A
Two 350 MHz input channels, plus optional third channel (6 GHz or 15 GHz)12 digits/second resolution, 100 p sec time interval resolution LXI-C/LAN, USB, GPIB Built-in math analysis and color, graphical display (trend and histogram)Optional: Lithium Ion Battery Bench Vue software enabled: Do more with your PC and instrument together, no programming required. Easily control your counters, quickly build automated tests and log data for faster analysis and save precious time.
-
product
110 GHz Frequency Extender
N5293AX53
The N5293AX53 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
120 GHz Frequency Extender
N5295AX03
The N5295AX03 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
120 GHz Frequency Extender, Pulsed DC Bias
N5295AX52
The N5295AX52 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
product
500 MHz Passive Probe for WaveJet Touch, 10:1, 10 MOhm
PP006D
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75R
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP022-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
RF & Microwave Passive Components
SHF Communication Technologies AG
SHF’s microwave components are broadband devices suitable up to 110 GHz. Our SHF BIAS TEES are well known but perhaps a slight variation does suit your application even better. DIPLEXERS are bias tees with a certain bandwidth in the low frequency path to combine or separate high frequency and low frequency signals into or out of a single line. DC-FEEDERS are bias tees without the capacitor. Therefore, it provides slightly lower insertion loss in case it is connected to an AC-coupled device which already has a capacitor on its input. Based on our air line construction, these passive components provide resonance-free transmission over the entire operating range.
-
product
NI-9326, 6-Channel, 150 V, 128 kHz C Series Frequency Input Module
786999-02
6-Channel, 150 V, 128 kHz C Series Frequency Input Module - The NI-9326 is a channel-to-channel isolated frequency input module for CompactDAQ and CompactRIO systems. This module includes six differential input channels with a 0 Vrms to 150 Vrms input range. The NI-9326 also features configurable thresholds for connection to a variety of variable reluctance sensors, single channel encoders, and hall-effect sensors. You can use the included embedded counters to perform frequency measurements or edge-counting for tracking total counts on a periodic signal. Additionally, the NI-9326 supports configurable Butterworth filters to help you perform low-noise frequency measurements.
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
350 MHz Universal Frequency Counter/Timer, 12 digits/s, 20 ps
53230A
The Keysight 53230A universal frequency counter/timer serves all your frequency and time interval measurement needs. In addition to the typical frequency and time interval measurements, continuous/gap-free measurements are available for basic modulation domain analysis. Optional burst measurement software is available. An optional microwave channel can be added to measure 6 or 15 GHz.
-
product
120 GHz Frequency Extender
N5295AX01
The N5295AX01 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Precision Capacitance Meter
TH2638B
Changzhou Tonghui Electronic Co., Ltd.
TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.
-
product
Active Differential Probe, 100 kHz to 7 GHz
U1818A
The Keysight U1818A 100 kHz to 7 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818A allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes
-
product
K-50 Series Probes
The K-50 coaxial probe provides an instrumentation-quality interface for broadband R.F. measurements up to 4 GHz. With the K-50 R. F. circuit design, impedance characterization measurements can be performed using it as a Network Analyzer port-extending accessory. Accurate and repeatable small signal and R.F. power (50 Watts) measurements provide consistent and repeatable results.
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L
Current Rating (Amps): 5Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 1.90Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
product
Frequency Multipliers
Triplers
*No mechanical tuners*fullband operation*planar design*zero Bias





























