-
product
Functional Testing
Interface Testingevaluation of correct system module interaction Smoke Testinginitial testing process to check whether software is ready for further testingSystem Testingconducted on a complete, integrated system to evaluate the system's compliance with its specified requirements Integration Testingperformed to test units of code to verify interaction between various software components and detect interface defectsRegression Testingtesting to ensure changes made are not impacting previously working functionality Acceptance Testingperformed to make sure the software handles required tasks in real-world scenarios, according to specifications
-
product
Film Frame Test Handler
4170-IH
High throughput ・High withstand load, and high thrust table ・Expansion of the strip attachment area :260(L) X 300(W) [Withinφ300mm for WLCSP]・LOT control by barcode/2D code reader ・Easy device type exchange only test socket and display screen setting・Auto-cleaning function unit is installed to clean the socket at any desired timing.・8/12 inches ring conversion ・S2/S8 regulation compliance・SEMI G85 compliance・SECS/GEM compliance
-
product
Real-Time In-Transit Logger
Monitors location, temperature, humidity, light, shockData transmitted via GSM cellular networksNo hardware or software installationAlerts and notifications via email and SMSGeofencing enabledNo need to open vehicle doors to access information24/7 cloud service to view and analyze data remotelyMake immediate cold chain management decisionsReroute trucks when necessaryCustomize settings for logging intervals, high/low alarm limitsData stored in the cloud for traceability, audits, HACCP, and FSMA compliance
-
product
Environmental Simulation Testing
MET's Environmental Simulation Labs, on both coasts, employ numerous environmental chambers, including several large walk-in chambers. Hydraulic and electro-dynamic shakers are used for a wide range of vibration testing, from ISTA packaging to seismic compliance testing. MET's hydraulic vibration systems are capable of full level (Zone 4) seismic simulation.
-
product
Infiniium S-Series High-Definition Oscilloscope: 8 GHz, 4 Analog Channels
DSOS804A
8 GHz bandwidth4 analog channels Capture a longer signal trace with 20 GSa/s max sample rate and 100 Mpts/channel of standard memory Get superior signal integrity with system ENOB of 6.4 bits and 10-bit analog-to-digital converter (ADC)Gain increased usability with the multi-touch supported 15 inch capacitive touch screen and solid state drive for fast boot and reliability Improve your testing with a wide range of protocol, compliance, and analysis software
-
product
RF Connectors
SMB Connectors
The SMB interface features a snap-on coupling mechanism and is available in 50 ohm configurations. SMB connectors conform to the requirements of MIL-C-39012, and the interface is in compliance with MIL-STD-348. SMB connectors offer broadband performance with low reflection DC to 4 GHz and extended performance up to 10 GHz.
-
product
PXI-4130, ±20 V, ±2 A DC, 40 W PXI Source Measure Unit
779647-31
±20 V, ±2 A DC, 40 W PXI Source Measure Unit - The PXI‑4130 is a programmable source measure unit (SMU). It has a single isolated SMU channel that offers a four-quadrant output that incorporates remote (4‑wire) sense. With its five current ranges, it is ideal for transistor characterization that requires accurately sourcing a constant current or voltage while sweeping another current. The PXI‑4130 also includes a utility channel that can source either current or voltage. This PXI SMU can act as either a constant voltage source or a constant current source, with a settable compliance limit for either mode. In addition, you can enable remote sense on the SMU channel to maximize voltage output and measurement accuracy on your device under test (DUT) for high-precision applications.
-
product
Audio Loudness Monitoring And Logging System
The Mividi® Audio Loudness Monitoring and Logging System (Loudness Logger) provides a cost-effective solution for broadcast compliance monitoring and logging. It is a Windows PC based system that supports audio decoding, loudness monitoring and logging, log file management and playback. It takes transport stream input from UDP over IP or ASI interfaces, as well as Internet OTT streaming input using HLS, RTMP, RTSP, and MPEG-DASH protocols. A single system can support continuous monitoring and recording over 50 channels simultaneously.
-
product
PCI Express 5.0 Transmitter Electrical Performance Validation and Compliance Software
D9050PCIC
Use the PCIe 5.0 Tx compliance software to test, debug and characterize your PCIe Gen5 designs quickly and easily. It automatically configures the oscilloscope for each test and generates an informative HTML report upon test completion. The application compares the results with the specification test limit and includes margin analysis which indicates how closely the device passes or fails each test. With the option InfiniiSim Waveform Transformation Toolset, the software supports integrated de-embedding of the breakout channel of the test fixture.
-
product
Accordion Custom Connectors
ECT’s Accordion Custom Connectors offer high reliability, high cycle life, patented single beam architecture providing a large range of usable compliance to absorb connector to target mating tolerances. With no requirement for a male to female target penetration, superior ease of use is achieved in blind mate scenarios with low insertion/extraction forces.
-
product
Paper Softness Tester ZRD-T1
The ZRD-T1 Paper Softness Tester is a device designed to objectively measure the softness of paper products, such as tissues, toilet paper, or specialty papers. Softness is a complex tactile property influenced by factors like surface smoothness, flexibility, and bulk compressibility. It is widely used in industries such as tissue manufacturing, hygiene product development, textiles, and packaging to ensure compliance with quality standards and end-user comfort requirements. This test instrument conforms to many national and international standards: ASTM D2923: Standard Test Method for Rigidity of Paper – Measures bending resistance to determine stiffness. ASTM D6828: Standard Test Method for Stiffness of Nonwoven Fabrics – Evaluates drape and flexibility in materials like medical textiles or wipes. TAPPI T498: Bending Resistance of Paper (Gurley Method) – Quantifies resistance to bending forces, inversely related to softness. GB/T 8942: Chinese Standard for Softness Testing of Household Paper – Aligns with consumer expectations for tissue and toilet paper tactile quality. ISO 12625-9: Softness Evaluation of Tissue Products (optional add-on).
-
product
Suite Of Data Analytics Software
Umetrics®
The Umetrics® Suite of data analytics software gives you access to powerful yet easy-to-use tools to optimize your manufacturing processes and bring quality products to market faster. Use the data analytics software to develop robust, high-quality products, continually improve processes and maintain control during manufacturing. These tools support regulatory compliance, enable digital transformation and facilitate quality by design.
-
product
Building Acoustics
Measurements to evaluate and improve Building Acoustics are typically made to analyze and design noise control from room to room, or from outside to inside. Noise sources such as music systems, televisions, appliances, traffic, aircraft, and manufacturing are all around us. The field of Building Acoustics evaluates and designs the materials and methods to insulate and isolate us all from these sound sources when we are at work, rest, or enjoying leisure time. The resulting data is useful for evaluating compliance with building codes and for proposing countermeasures for areas of concern. These measurements often involve creating and measuring an artificial sound source, and then measuring the resulting noise in receiver locations.
-
product
Handheld Water Quality Meters
LAQUA PC220
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
product
Software Composition Analysis
SCA
Black Duck® software composition analysis (SCA) helps teams manage the security, quality, and license compliance risks that come from the use of open source and third-party code in applications and containers.
-
product
1GHz EMC Emissions Analyser
SA1002
The SA1002 provides a high performance capability to measure the EMC compliance of your products. It covers the conducted emission and radiated emission bands to 1GHz, as required by most EMC standards. The included software is Windows compatible and simple to use. This powerful system automatically sets the analyser parameters to suit the test to be performed. Standard limits are available from simple pull-down menu. Results can be directly compared against these limits for easy checks on compliance status.
-
product
VibA(8) Hand-Arm Vibration System
VK040
Ultra-simple and dedicated to compliance of the Vibration at Work Regulations 2005, this is the perfect option for your Hand-Arm Vibration measurements with the added benefit of being able to add a Whole-Body Seat Pad at any time further down the line.
-
product
DC System Power Supply, 60V, 12.5A, 750W
N5747A
The single output, 750W N5747A provides universal AC input, GPIB, LAN, USB, LXI compliance, and analog/resistance control of output voltage and current.
-
product
Highly Scalable Gaming Platform Based on 10th Gen Intel® Core™ Processors Supports up to Seven Independent Displays Including 4K UHD
ADi-SA3X-CL
ADLINK‘s ADi-SA3X-CL all-in-one gaming platform features powerful processing and graphics performance for gaming and retail. Equipped with 10th Generation Intel® Core™ processors, the ADi-SA3X-CL provides compelling graphics performance from a PCI Express 3.0 x16 discrete graphics card and/or an embedded Intel® UHD Graphics 630/610 supporting up to seven independent monitors. With the powerful processing performance, advanced security functions, smart middleware solutions, and versatile I/O array, the ADi-SA3X-CL fully satisfies the needs of your gaming application. The ADi-SA3X-CL is a true application-ready gaming platform providing OEMs with a highly flexible and reliable all-in-one system that offers unparalleled portfolio of services that help developers save time and pass compliance. The platform is designed to meet the GLI- 11 (Gaming Laboratories International) certification and all major global gaming market compliance requirements.
-
product
Broadcast Compliance Recording and Monitoring Platform
Actus View
Actus View is a professional broadcast compliance recording and monitoring platform for recording any number of TV or radio channels, from any input and any format. Actus View broadcast monitoring system complies with the media regulation authorities requirements, such as the FCC compliance specifications.
-
product
Atomic Spectroscopy Software
The range of Agilent atomic spectroscopy software, available with and without compliance solutions, includes SpectrAA, MP Expert, ICP Expert and ICP-MS MassHunter software.
-
product
Cell Solar Simulator
QuickSun® 130E
QuickSun 130E exceeds the ordinary Class A criterions of IEC904-9 ed. 2 with clear margin providing enhanced IV characteristics accuracy. The applicable test methods and procedures are inspected by SGS Fimko Ltd in order to guarantee the compliance and traceability not only with the above standard but also with IEC904-1 ed. 2 which specifies the IV measurement conditions.
-
product
Testing Services
Austin Labs is the industry leading third-party testing facility. We help our customers overcome testing challenges in their products including Data Integrity, Performance Analysis, Protocol Analysis and compliance, Error Injection, Signal Integrity, Electrical Compliance, Interoperability, Technical Consulting, Design and Feasibility.
-
product
Emissions Test System
PC-114
Perform Radiated & Conducted EMI pre-compliance testing at your facility up to 1 GHz. Com-Power PC-114 EMI emissions test system is a ideal solution performing pre-compliance EMC testing from 9 kHz - 1 GHz.. It has essential equipment needed for radiated and conducted EMI emissions measurements. The system includes a spectrum analyzer, antennas, near field probes, a preamplifier, LISN and a non conductive antenna tripod. Pre-compliance testing in EMC is a commonly used term not easy to define. In general, it implies testing done prior to formal testing for legal compliance. Formal legal compliance is performed at a facility designed and equipped with test instrumentation that is fully compliant with the applicable EMC standards. Such facility and instrumentation is capital intensive and can be expensive even to rent and not easily available. Compliance testing is performed per exacting requirements of the Standards and other reference documents adhering to the test methods and last detail. In addition, the test facility may require to be accredited by an accreditation body such as NVLAP, A2LA. Often it is desirable to know prior to compliance testing at such facility, whether a product is close to compliance and also how close. Pre-compliance testing is specially useful for specifications such as FCC, Part 15, EN 55022 or EN 55011 (CISPR 22 or CISPR11). Pre-compliance testing usually means using the full compliance methods but making a few educated compromises in use of site or equipment to reduce costs and testing time. Here are some benefits of pre-compliance testing.
-
product
Pulse Adapter
CV30P650
Frothingham Electronics Corporation
The CV30 P650 test station is currently the highest voltage pulser in a series of exponential pulse generators that can be connected to our FEC200E tester. This gives you all the versatility of the proven FEC200 with the addition of high power exponential pulses. The CV30 P650 pulse adapter can produce a maximum current of 100A at up to 600V using exponential pulses up the 10/1000 waveform. The pulser is rated at 30KW from 300V to 650V. Voltage compliance at 100A is 600V. The station can also include all of the usual FEC200 tests in the same test program.
-
product
Ensure Accurate Screening, Diagnosis and Monitoring
CT QA Solutions
Over 40 years of experience helping our customers with CT compliance and patient safety. From CT Perfusion verification, to Dual Energy Characterization, to daily, monthly and annual CT QC, Gammex is your trusted CT QA and compliance partner.

























