Showing results: 4711 - 4725 of 5238 items found.
-
7751TG2-HD -
Evertz Microsystems Ltd.
The 7751TG2-HD Test Signal Generator provides a cost-effective method of generating 1.5Gb/s HDTV 4:2:2 and 4:4:4 test signals. The 7751TG2-HD is ideal for checking signal path integrity, or to determine system performance over varying cable lengths. The 7751TG2-HD generates test signals in a wide variety of SMPTE 292M video formats.
-
COMBI519 -
HT Italia Srl
COMBI519 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
COMBI521 -
HT Italia Srl
COMBI521 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
EASYTEST -
HT Italia Srl
EASYTEST carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
Bloomy Controls, Inc.
Reliable connections to device under test (DUT) test points are essential for robust functional test. Bloomy provides rugged fixtures and cable sets (ITAs) built for thousands and thousands of cycles in manufacturing environments. With the industry’s best mass interconnects and internal electronic keying, our fixtures are easy to change out and are automatically recognized by the test system.
-
Extech 380562 -
Extech Instruments Corporation
Compact and precise, the Extech 380562 Milliohm Meter has 7 ranges and measures down to 0.01mΩ using 4-wire Kelvin clip test leads. Measurements are displayed on the unit's large 0.8", 1999-count LCD. Built-in comparator for Hi/Lo/Go resistance testing or selection. Complete with 4-wire cables with Kelvin clip connectors and power cord.
-
GPIB -
Test Electronics
Test Electronics will customize the TE3000 GPIB signal routing box for your test application. Then, you simply rack and stack all the equipment, cable all the switched signals to the back of this GPIB box, add a rack mount computer, plug in the National Instruments GPIB board and software. Then run your customized GPIB based test system.
-
FExx Series -
Rohde & Schwarz GmbH & Co. KG
R&S®FExx external frontends extend the frequency ranges of Rohde & Schwarz signal and spectrum analyzers and signal generators up to 170 GHz. The R&S®FExx enables the up and down-conversion of the signal directly at the DUT. In an OTA environment it lowers cable losses, increases sensitivity and delivers more power at the antenna.
-
S94USBCB -
Keysight Technologies
Use the S94USBCB software to test, debug and characterize your USB Type-C cable and connector designs. The PathWave TAP based test sequencer automates the network analyzer (VNA) for each test and generates a comprehensive HTML report. When run with L8990M switch matrix, it enables 20-ports fully automated test without port re-connection.
-
E1708A -
Keysight Technologies
The Keysight E1708A uses an optical fiber to transport the laser beam from a remote sensor assembly to the electronics. This improves measurement accuracy and repeatability by enabling you to mount heat-producing electronics away from the measurement area. The fiber optic cable also provides increased mounting design flexibility and easier access to the receiver attenuation and squelch adjustments.
-
10780C -
Keysight Technologies
The Keysight 10780C is a highly-sensitive, lowest-cost Keysight receiver used with laser interferometer positioning systems. One receiver is used per measurement axis (including wavelength tracker). Configured with Keysight electronics, laser heads, cables and optics, the Keysight 10780C receiver allows you tailor a precise positioning system for your exact application requirements.
-
779501-01 -
NI
MXI-Express Interface, PXI Remote Control Module—The PXI‑8360 allows you to control PXI and CompactPCI systems from your PC using a fully transparent MXI‑Express link. It is installed in a PXI chassis and uses a PCI Express‑to‑PCI bridge to interface with an installed PCI‑8360 through a copper, x1 MXI‑Express cable.
-
CM8856 -
Rinch Industrial Co.,Limited
* It meets the standards of both ISO2178 and ISO 2361 as well as DIN, ASTM and BS. It can be used both in the laboratory and in harsh field conditions.* The F probes measure the thickness of non-magnetic materials (e.g. paint,plastic, porcelain enamel, copper, zinc,aluminum , chrome etc.) on magnetic materials (e.g. iron, nickel etc.) . often used to measure the thickness ofgalvanizing layer, lacquer layer, porcelain enamel layer, phosphide layer, copper tile, aluminum tile, somealloy tile, paper etc.The N probes measure the thickness of non - magnetic coatings on non-magnetic metals .It is used on anodizing, varnish, paint, enamel,plastic coatings, powder, etc. appliedto aluminum, brass, non-magnetic stainless steel, etc.* Automatic substrate recognition.* Manual or automatic shut down.* Two measurement mode: Single andContinuous* Wide measuring range and highresolution.* Metric/Imperial conversion.* Digital backlit display gives exactreading with no guessing or errors.* Can communicate with PC computerfor statistics and printing by theoptional cable.* Can store 99 groups of measurements.* Statistics is available.2.SPECIFICATIONSDisplay: 4 digits LCD, backlitRange: 0~1250 μm/0~50mil(other ranges can be specified )Min.radius workpiece: F: Convex 1.5mm/Concave 25mmN: Convex 3mm/ Concave 50mmMin. measuring area: 6mmMin.Sample thickness : 0.3mmResolution: 0.1 μm (0~99.9μm);1 μm (over 100μm)Accuracy: ±1~3%n or 2.5 μm or 0.1mil(Whichever is the greater)Bttery Indicator: Low batter indicator.PC interface: with RS-232C interfacePower supply: 2x1.5 AAA(UM-4) batteryOperating condition: Temp. 0~50℃ .Humidity <95% .Size: 126x65x35 mm; 5.0x2.6x1.6 inchWeight: about 81g(not including batteries)Standard accessories:Carrying case ...................1 pc.Operation manual ............ 1 pc.F probe in built .................1 pc.NF probe in built...............1 pc.Calibration foils ..............1set.Substrate (Iron) ................1 pc.Substrate (Aluminium)......1 pc.Optional accessories: RS-232C cable & software:1.USB adaptor for RS-232C2.Bluetooth interface
-
CM8855 -
Rinch Industrial Co.,Limited
It meets the standards of both ISO2178 and ISO 2361 as well as DIN, ASTMand BS. It can be used both in the laboratory and in harsh field conditions. The F probes measure the thickness of non-magnetic materials (e.g. paint,plastic, porcelain enamel, copper, zinc, aluminum , chrome etc.) on magneticmaterials (e.g. iron, nickel etc.) . often used to measure the thickness ofgalvanizing layer, lacquer layer,porcelain enamel layer, phosphidelayer, copper tile, aluminum tile, some alloy tile, paper etc. The N probes measure the thickness of non - magnetic coatings on non-magnetic metals .It is used on anodizing, varnish, paint, enamel,plastic coatings, powder, etc. appliedto aluminum, brass, non-magnetic stainless steel, etc. Automatic substrate recognition. Manual or automatic shut down. Two measurement mode: Single and Continuous Wide measuring range and high resolution. Metric/Imperial conversion. Digital backlit display gives exact reading with no guessing or errors. Can communicate with PC computer for statistics and printing by the optional cable. Can store 99 groups of measurements. Statistics is available.2.SPECIFICATIONSDisplay: 4 digits LCD, backlitRange: 0~1250 μm/0~50mil (other ranges can be specified )Min.radius workpiece: F: Convex 1.5mm/Concave 25mmN: Convex 3mm/ Concave 50mmMin. measuring area: 6mmMin.Sample thickness : 0.3mmResolution: 0.1 μm (0~99.9μm);1 μm (over 100μm)Accuracy: ±1~3%n or 2.5 μm or 0.1mil(Whichever is the greater)Bttery Indicator: Low batter indicator.PC interface: with RS-232C interfacePower supply: 2x1.5 AAA(UM-4) batteryOperating condition: Temp. 0~50℃ .Humidity <95% .Size: 126x65x35 mm; 5.0x2.6x1.6 inchWeight: about 81g(not including batteries)Standard accessories:Carrying case ...................1 pc.Operation manual ............ 1 pc.F probe in built .................1 pc.NF probe in built...............1 pc.Calibration foils ..............1set.Substrate (Iron) ................1 pc.Substrate (Aluminium)......1 pc.Optional accessories: RS-232C cable & software:1.USB adaptor for RS-232C2.Bluetooth interface
-
MR3 -
Alpha Lab, Inc.
The MR3 Magnetoresistive Milligauss Meter measures and displays the three vectorcomponents (X, Y, Z) as well as the magnitude (M) of the static magnetic field. Update is two times per second. The three sensors are in a 25 mm (1") cube at the end of a flexible 100 cm (40") cable. It can be powered by 4 AA batteries (included) or a Worldwide AC adaptor (included). It can collect and store data (X, Y, Z and M) for later download or stream data live via USB connector. Both the instantaneous values of X, Y, Z and M, and their peak values, are displayed on the meter screen. "Peak" values are the highest values seen since the peak reset button was pressed. Maximum error of sensitivity is +/- 0.5 % of the reading, and the maximum error of the offset is +/- 0.50 milligauss. Range is +/- 1999.99 milligauss with resolution 0.01 milligauss (or 1 nT) over the full range, displayed simultaneously for X, Y, Z and M.