Filter Results By:

Products

Applications

Manufacturers

Showing results: 3031 - 3045 of 3569 items found.

  • PXI-2512, 7-Channel, 10 A PXI Signal Insertion Switch Module

    778572-12 - NI

    7-Channel, 10 A PXI Signal Insertion Switch Module—The PXI‑2512 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2512 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls

  • NI-9246, 50 kS/s/ch, 20 Arms, 30 Apk, 24-Bit, 3-Channel C Series Current Input Module

    783920-01 - NI

    50 kS/s/ch, 20 Arms, 30 Apk, 24-Bit, 3-Channel C Series Current Input Module - The NI‑9246 is designed to support direct ring lug connectivity to the three-phase high-current measurements of 1 A and 5 A current transformers (CTs). It is optimized for power, energy, and industrial applications. The safety features, certifications, input ranges, overvoltage ranges, and connectivity are well suited for applications such as power quality monitoring and metering, utility pole-mounted smart switches, utility pole-mounted smart grid reclosers, substation merging units, industrial machine measurements, health monitoring, predictive maintenance and prognostics, and phasor measurement units (PMUs).

  • PXIe-1086DC, 18-Slot (16 Hybrid Slots, 1 PXI Express Slot), DC Power Supply, Up to 12 GB/s PXI Chassis

    787137-01 - NI

    PXIe, 18-Slot (16 Hybrid Slots, 1 PXI Express Slot), DC Power Supply, Up to 12 GB/s PXI Chassis - The PXIe‑1086DC incorporates hot-swappable, redundant DC power supplies as well as hot-swappable, front-accessible, redundant cooling fans. These high-availability features improve the mean time between failure (MTBF) and mean time to repair (MTTR) of the PXI system. The PXIe‑1086DC monitors power supply health/voltages, air intake temperature, and fan health/speed; it provides any failure feedback with the status LEDs located on the chassis. This chassis is ideal for test, measurement, and control applications with demanding system uptime requirements.

  • sbRIO-9225, Non-Enclosed, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module

    780588-01 - NI

    Non-Enclosed, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module - The sbRIO‑9225 performs differential analog input. The wide measurement range is well suited for high-voltage measurement applications such as power metering, power quality monitoring, motor test, battery stack testing, and fuel cell tests. You can perform transient and harmonic analysis with high-speed simultaneous sampling. In addition, you can prevent ground loops and add safety to a system with 600 Vrms channel‑to‑channel isolation between the three sbRIO‑9225 channels. Non-enclosed modules are designed for OEM applications.

  • USB-6366, 8 AI (16-Bit, 2 MS/s), 2 AO (3.33 MS/s), 24 DIO USB Multifunction I/O Device

    781445-02 - NI

    8 AI (16-Bit, 2 MS/s), 2 AO (3.33 MS/s), 24 DIO USB Multifunction I/O Device - The USB-6366 is a simultaneous sampling, multifunction DAQ device. It offers analog I/O, digital I/O, and four 32-bit counters/timers for PWM, encoder, frequency, event counting, and more. Onboard … NI-STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The USB-6366 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.

  • USB-6366, 8 AI (16-Bit, 2 MS/s), 2 AO (3.33 MS/s), 24 DIO USB Multifunction I/O Device

    782263-01 - NI

    8 AI (16-Bit, 2 MS/s), 2 AO (3.33 MS/s), 24 DIO USB Multifunction I/O Device - The USB-6366 is a simultaneous sampling, multifunction DAQ device. It offers analog I/O, digital I/O, and four 32-bit counters/timers for PWM, encoder, frequency, event counting, and more. Onboard NI-STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The USB-6366 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.

  • USB-6366, 8 AI (16-Bit, 2 MS/s), 2 AO (3.33 MS/s), 24 DIO USB Multifunction I/O Device

    782264-01 - NI

    8 AI (16-Bit, 2 MS/s), 2 AO (3.33 MS/s), 24 DIO USB Multifunction I/O Device - The USB-6366 is a simultaneous sampling, multifunction DAQ device. It offers analog I/O, digital I/O, and four 32-bit counters/timers for PWM, encoder, frequency, event counting, and more. Onboard NI-STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The USB-6366 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.

  • NI-9247, 50 kS/s/ch, 50 Arms, 147 Apk, 24-Bit, 3-Channel C Series Current Input Module

    783589-01 - NI

    50 kS/s/ch, 50 Arms, 147 Apk, 24-Bit, 3-Channel C Series Current Input Module - The NI‑9247 is designed to support direct ring lug connectivity to the three-phase high-current measurements of 1 A and 5 A current transformers (CTs). It is optimized for power, energy, and industrial applications. The safety features, certifications, input ranges, overvoltage ranges, and connectivity are well suited for applications such as power quality monitoring and metering, utility pole-mounted smart switches, utility pole-mounted smart grid reclosers, substation merging units, industrial machine measurements, health monitoring, predictive maintenance and prognostics, and phasor measurement units (PMUs).

  • USB-6353 , 32 AI, (16-Bit, 1.25 MS/s), 4 AO (2.86 MS/s), 48 DIO USB Multifunction I/O Device

    781441-01 - NI

    32 AI, (16-Bit, 1.25 MS/s), 4 AO (2.86 MS/s), 48 DIO USB Multifunction I/O Device - The USB‑6353 offers analog I/O, digital I/O, and four 32‑bit counters/timers for PWM, encoder, frequency, event counting, and more. Onboard NI‑STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The USB‑6353 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • PXIe Audio Analyzer

    M9260A - Keysight Technologies

    M9260A is significantly different from the traditional general purpose PXI digitizer modules which are being used for today's audio measurement. In order to achieve fast test speed and high performance it comes with large one million sample arbitrary waveform buffer and one million sample "limitless" input buffer, as well as super-linear/low noise amplifiers and digital to analog converters. This enables M9260A's ultra-low residual distortion and high amplitude accuracy. M9260A is now an important part of Keysight Radio Test Solution, and may also be easily integrated into any audio related PXI test system with its developer-friendly drivers and commands.

  • Spectrum Analysis, Up To 13.5 GHz

    S930901B - Keysight Technologies

    The S930901B spectrum analysis adds high-performance microwave spectrum analysis to the PNA family up to 13.5 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • cDAQ-9178, 8‑Slot, USB CompactDAQ Chassis

    781156-01 - NI

    8‑Slot, USB CompactDAQ Chassis - The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. It also controls the timing, synchronization, and data … transfer between C Series I/O modules and an external host. You can use this chassis with a combination of C Series I/O modules to create a mix of analog I/O, digital I/O, and counter/timer measurements. The cDAQ‑9178 also has four 32‑bit general-purpose counters/timers. You can access these counters, as well as share clocks and triggers, through two built-in BNC connectors.

  • USB-6356, 8 AI (16-Bit, 1.25 MS/s), 2 AO (3.33 MS/s), 24 DIO USB Multifunction I/O Device

    781444-02 - NI

    8 AI (16-Bit, 1.25 MS/s), 2 AO (3.33 MS/s), 24 DIO USB Multifunction I/O Device - The USB-6356 is a simultaneous sampling, multifunction DAQ device. It offers analog I/O, digital I/O, and four 32-bit counters/timers for PWM, encoder, frequency, event counting, and more. Onboard NI-STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The USB-6356 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.

  • USB-6356, 8 AI (16-Bit, 1.25 MS/s), 2 AO (3.33 MS/s), 24 DIO USB Multifunction I/O Device

    781444-01 - NI

    8 AI (16-Bit, 1.25 MS/s), 2 AO (3.33 MS/s), 24 DIO USB Multifunction I/O Device - The USB-6356 is a simultaneous sampling, multifunction DAQ device. It offers analog I/O, digital I/O, and four 32-bit counters/timers for PWM, encoder, frequency, event counting, and more. Onboard NI-STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The USB-6356 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.

  • USB-6356, 8 AI (16-Bit, 1.25 MS/s), 2 AO (3.33 MS/s), 24 DIO USB Multifunction I/O Device

    782260-01 - NI

    8 AI (16-Bit, 1.25 MS/s), 2 AO (3.33 MS/s), 24 DIO USB Multifunction I/O Device - The USB-6356 is a simultaneous sampling, multifunction DAQ device. It offers analog I/O, digital I/O, and four 32-bit counters/timers for PWM, encoder, frequency, event counting, and more. Onboard NI-STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The USB-6356 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.

Get Help