Filter Results By:

Products

Applications

Manufacturers

Air

the atmosphere surrounding earth.

See Also: Air Quality, Atmosphere


Showing results: 1321 - 1335 of 1529 items found.

  • Particle Counter

    ST-9880 - Standard Instruments Co., LTD.

    This particle counter comes with a 2.8” TFT color LCD display for a gratifying visual effect. The camera function allows capturing JPEG images and 3GP videos conveniently. This versatile particle counter is widely used. 2.8'''' color TFT LCD display. With a micro SD memory card to view images and videos on your PC. Gas (HCHO, CO) detector. Air temperature and relative humidity measurement.

  • Ventilator Test System

    4070 - TSI Inc.

    The Certifier® FA Ventilator Test System 4070 is capable of testing multiple parameters of ventilator performance. It is designed to measure air, oxygen, and nitrous oxide flow and pressure in institutional, home care, field service, laboratory, and production applications. The Certifier FA ventilator test system is a battery-operated flow analyzer that can also test a variety of other medical equipment such as anesthesia gas delivery machines and oxygen concentrators.

  • Wavelength Tracker

    10717A - Keysight Technologies

    The Keysight 10717A Wavelength Tracker tracks changes in the air's index of refraction to optically compensate for environmental changes. It uses one axis of a laser measurement system to report wavelength of light changes, not changes in position. It is used to correct displacement values reported by other measurement axes in the system, hence improving measurement accuracy. It provides a higher degree of accuracy than environmental sensors such as the 10751C and 10751D Air Sensors.

  • Medical Grade All-in-One Panel Computer with 13.3”/15.6” Full HD Display

    MLC-AL/ MLC-KL - ADLINK Technology Inc.

    The MLC-AL/MLC-KL Series of medical panel computers feature a fully sealed aluminum housing for easy cleaning. As a result of its hygienic surface design that eliminates exposed screw heads and air vents, the MLC-AL/MLC-KL Series can be easily and quickly cleaned using all common disinfectants and cleaning agents.The MLC-AL/MLC-KL comes in two display sizes, 13.3” and 15.6”, which are ideal for ICUs, emergency rooms and the hospital wards. In addition to the standard galvanically isolated network connections, the MLC-AL/MLC-KL can be optionally equipped with galvanically isolated USB and serial interfaces for connection to external non-medical devices. Compliant with 2x MOPP, the MLC-AL/MLC-KL meets the comprehensive requirements of the IEC/EN-60601-1 (Edition 3.1) and IEC/EN-60601-1-2 (4th Edition) standards.

  • MSX® Thermal Camera

    FLIR TG165-X - Teledyne FLIR

    The FLIR TG165-X helps you visualize the hot and cold spots that can indicate electrical faults, mechanical break-downs, or air and water leaks. This all-in-one, non-contact measurement and imaging tool displays temperature anomalies on screen, allowing you to inspect efficiently and pinpoint the source of problems faster than with a single-spot IR thermometer. See components clearly and even read labels thanks to FLIR patented MSX image enhancement, which adds visual details to full thermal images. The bullseye laser ensures you’re always targeting the right component for measurement while easy-to-use buttons and settings help you complete the job quickly and stress-free. With internal storage for up to 50,000 images and a rechargeable Li-ion battery, the FLIR TG165-X is ready to go right out of the box.

  • Spectrometer

    Model 207 - McPherson, Inc.

    The Model 207 offers the user the most throughput and fastest aperture in a long focal length monochromator. This is ideal for photoluminescence and Raman spectroscopy applications. It is also available in a vacuum compatible version. Used in air and with a selection of gratings, the spectral range of the 207 extends from 185 nanometersm to 20 microns or more. Under vacuum range is extended down to 105 nm (depends on the grating.) Multiple ports are available for mounting accessories or CCD detectors, etc. McPherson SNAP IN gratings allow the alignment-free use of many different gratings. Easily view a wider spectral range or obtain higher resolution! You can retrofit years later and not have to worry about alignment with the McPherson SNAP IN approach. Our dual grating turret also accepts these easy to exchange gratings.

  • CAPS Trace-Level NO2 Analyzer

    Model T500U - Teledyne Advanced Pollution Instrumentation

    The T500U CAPS NO2 Analyzer represents the next generation of criteria pollutant monitoring technology for the direct measurement of Nitrogen Dioxide (NO2) in air. The instrument utilizes a patented Cavity Attenuated Phase Shift (CAPS) technique to provide an extremely sensitive, fast and accurate NO2 measurement in a cost effective and low maintenance instrument package.The T500U provides a direct NO2 measurement, eliminating the need for catalytic conversion or reagents which introduce measurement artifacts inherent in traditional heated metal converter based chemiluminescense instruments. The CAPS measurement approach also reduces maintenance items, and removes the need for hazardous materials and high temperature scrubbers within the instrument. The T500U has an expected maintenance interval of one year under typical ambient monitoring conditions.

  • Ruggedized Field Deployable Fiber Transport

    Field Fiber Series - Multidyne

    It’s a tough world out there. Whether onboard a truck, inside a sports venue or outside in the open air, our customers consistently work in harsh, high-pressure production environments. The rigors of long-distance road transport and inclement weather will not excuse failure during live sports, events and broadcast news production. They also must contend with signal counts and connectivity requirements that change with each event. MultiDyne is trusted worldwide for durable, flexible, battery-powered field fiber systems that users can safely transport between events and confidently deploy with broadcast quality signal I/O. With solutions for productions of any scale, including ultra-compact throwdown devices, rackmount units and fully configurable, high-density portable systems, MultiDyne’s field fiber solutions optimize reliability for any short-haul and long-distance field application.

  • LED Floodlight up to 6000m, 120Vac 10,000 Lumen

    U Light - Teledyne Marine Bowtech

    The Teledyne Bowtech U light is for use on subsea platforms that operate down to 6000m depths, requiring a 120Vac Ultra- bright 10,000 lumen, LED Floodlight. The 80° wide LED floodlight beam angle is ideal for colour video inspection tasks. Housed in hard anodised aluminium, this deepwater LED floodlight measures in at 82mm Ø by 148.4mm long and comes with thermal protection ensuring that the light does not overheat if accidentally run in air. The U Light has the capability of being controlled externally by normal ON / OFF power switching or by using phase control diming techniques enabling the operator to produce a varying level of light intensity. This extremely robust U Light LED floodlight is ideal for clear visibility in deep depths on larger work class ROVs, Trenchers and Tractors.

  • Piezobalance Dust Monitor

    3520 Series - KANOMAX USA, Inc.

    The Kanomax Piezobalance Dust Monitor 3521/3522 is a unique respirable aerosol monitor, providing direct mass concentration of particulates using PIEZOBALANCE technology; ideal especially for oil mist monitoring. The Kanomax 3521 is equipped with 4 and 10µm impactors while the 3522 is equipped with a 2.5µm impactor. Unlike conventional dust meters, which count particles, a piezobalance dust meter like the 3521 or 3522 “weighs” mass concentration of particulates. As an air sample enters the system, it travels through the impactor, which captures and removes larger particulates away from the sample. Smaller particulates become electrically charged and deposited on the piezo-crystal. The total mass of the deposited particulates affects the piezo-crystal’s frequency. Since the change in frequency is proportional to the mass of the particulates, the actual weight of the particulates is obtained.

  • BET Flowing Gas Surface Area Analyzers

    SA-9600 Series - HORIBA, Ltd.

    The surface area of a material is, in many cases, as important as the chemical properties. As particle size decreases, surface area increases. Porosity of materials - from micropores to macropores - contribute even more to the total surface area. The interface at the surface is what defines how a solid reacts to other substances, be they gases, liquids, or solids.Surface area can impact shelf life, stability, dissolution and efficacy of pharmaceutical powders and tablets. Likewise, surface area can affect the rheological properties and hiding powers of pigments, paints, and coatings. It has a significant impact on the ability for materials like catalysts, adsorbents, filtration materials and air separation products to react in the designed application. Ceramics used in applications ranging from; dinner plates, to dental implants, to electronics, all are affected by surface area.

  • Pressure Control Machine

    EQ-6V / EQ-12V - Hitec Co., Ltd.

    The constant pressure device enables the stable supply of materials to the stuffing machine by keeping constant the pressure to the materials in the pipe fed from the pump to the stuffing machine side by air pressure. When the materials being fed from the pump, the surplus materials unnecessary to be stuffed shall be sent into the constant pressure cylinder. And when the constant pressure cylinder is full, the supply from the pump shall be stopped and then the materials in the cylinder shall be discharged into the pipe by constant pressure. Accordingly, it is unnecessary to synchronize the stuffing speed with the pump speed by every product. Also, the pressure shortagegenerated when the pump motor starts and the effect of pressure fluctuation in the pipe due to the changes of the speeds of the pump motor and stuffing machine can be minimized so that it is possible to supply stably the materials to plural stuffing machines.

  • Flash Chromatography System for Flow Rates from 1 to 300 mL/min, Operating Pressures up to 300 psi (20 bar)

    CombiFlash NextGen 300+ - Teledyne LABS

    The CombiFlash® NextGen 300+ features all available performance and safety options. Flow rate range is from 1 to 300 mL/min at operating pressures up to 300 psi (20 bar). The system is fitted with a solid load injection valve that can be bypassed if you decide to perform a liquid injection. RFID technology comes standard and automatically reads the size and type of RediSep or RediSep Gold® column being used for the purification. Based on this information, a default gradient and flow rate are programmed in​to the system. Simply insert the column into the stand, press Play and the run starts. This same RFID technology automatically reads the rack type being used ensuring there is never a missed or overfilled tube. Active solvent and waste level sensing, along with column air purge, is standard is standard on the NextGen 300+.

  • *High Current Switches

    B-1002 - Ruetz Technologies GmbH

    Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force.  Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz.  Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit.  Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas.  For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.

  • High Current Switches

    B-1002 - ROSS ENGINEERING CORPORATION

    Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force.  Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz.  Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit.  Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas.  For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.

Get Help