Millimeter Wave
extremely High Frequency in the range of 30 to 300 gigahertz.
See Also: Wave, Extremely High Frequency, Long-Wave IR, Lightwave, Shear Wave, Sub-mm Wave, Microwave, Wavelet, Continuous Wave, Submillimeter Wave, Sine Wave, Shock wave, mmWave, MW
-
Product
Test Port Adapter Set, 2.4 Mm To 3.5 Mm
85130F
Test Port Adapter
The Keysight 85130F test port adapter protects the test set port from connecting directly with the device under test. It has a special rugged female connector designed for connecting to the network analyzer test port. This special connector does not mate with a standard male connector but converts the rugged test set port to a connection that will mate with the device under test. The set contains a 2.4 mm to PSC-3.5 mm male adapter and a 2.4 mm to PSC-3.5 mm female adapter. The frequency range for these adapters is dc to 26.5 GHz with a return loss of 26 dB or better.
-
Product
Frequency Expansion Modules
-
bsw TestSystems & Consulting AG
Up To 1.5THz For Network Analyzers Modern communication standards, like for instance 5G, place high demands on components (mixers, amplifiers, antennas, etc.), which have to be examined in high frequency bands (millimeter waves); the requirements include: broad frequency coverage, sufficient output power to operate the components under compression, high dynamic range and stability as well as a reduced dynamic content within the spectrum.
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72I40-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Amplifier Built-in / U-shaped Micro Photoelectric Sensor [Ultra-small / Cable Type]
PM-25
-
Panasonic Industrial Devices Sales Company of America
The Panasonic PM-25 Sensor has a beam emitting / receiving distance of 6 mm. The beam emitting and receiving areas are 0.5 mm thinner compared to conventional models even though the external dimensions have not changed. As a result, the distance between the beam-emitting and the beam-receiving points have increased by 1mm thereby reducing the possibility of sensing objects colliding.
-
Product
High 1.73 (49.00) - 8.00 (127.00) High Performance Lead Free Probe
LFRE-1L24-8
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
01 With Pins For PCB | 10 Positions | M8
01-1xxx-20/70xx-10-0
-
Multi wafer compact selector with 36° detent angle, 4 mm shaft diameter, 25'000 switching cycles and with up to 6 Ncm switching torque
-
Product
High 2.84 (81.00) - 8.00 (227.00) High Performance Lead Free Probe
LFRE-25J-8
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Alternate 1.10 (31.18) - 7.20 (204.00) Switch Probe
TSP100-H180-2
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
RF Frequency Multipliers
-
Frequency multipliers are devices that produce an output signal where the frequency is a multiple of the input signal. The multiple can be 2x (i.e. a Frequency doubler), 3x, 4x and so on.Precision MMW will help you with the highest quality rf frequency multiplier products needs. We are a millimeter wave spectrum manufacturer of various active and passive mmWave products and sub-system engineering.View more RF Frequency Multiplier
-
Product
Digital Accelerometer
ZET 7152-N-VER.1
-
Digital accelerometer ZET 7152-N-VER.1 has a compact triaxial sensing element; it is purposed to measure linear acceleration and vibration acceleration variable component in three mutually perpendicular planes. Light weight of sensing element (only 1.5 g) considerably decreases self-mass load effect, and compact dimensions (8.5×8.5×8.5 mm) allow using ZET 7152-N-VER.1 digital accelerometer to measure vibration in small work-area systems.
-
Product
Alternate 2.64 (75.00) - 6.50 (184.00) General Purpose Probe
EPA-2L-1
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62H-4-S
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Cup, Concave 90/120°, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0A
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Mini Redundant Power Supply; ATX 500W (AC Inlet In Front )
PS501-HRP
-
*Input Range: 100~ 240VAC Full Range*Output Voltage:**+5V, 25A**+3.3V, 25A**+12V, 41A**-12V, 0.8A**-5Vsb, 3.5A*MTBF(hours): AT 25°C 100,000h*Safety: CB, CCC, UL, TUV, CE, FCC*Dimensions: 185 x 150 x 86 mm*Compatible with Axiomtek products: AX6156LE/AX61220
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
High Frequency Probe
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
2.96 mm (M) to 2.96 mm (M) 40 GHz RF Cable
GAU1-292M292M-XXX
-
UCINSTRUMENTS GAU1-292M292M-XXX 147A SERIES, FLEXIBLE CABLE 2.92MM(MALE)‐ 2.92MM(MALE)
-
Product
P2665 General Purpose Probes
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
High 2.84 (81.00) - 8.00 (227.00) High Performance Lead Free Probe
LFRE-25Z-8
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Waveguide Power Amplifiers
-
RF solid state power amplifier (SSPA) PE15A4006 from Pasternack is part of the largest selection of in-stock radio frequency microwave and millimeter wave amplifiers available for same-day shipment. This Pasternack solid state RF power amplifier is a medium power amp design constructed in a connectorized package. Our SSPA is designed with SMA connectors and rated at 1 Watt.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1B-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Thermitest
THW-L2
-
Designed with speed and operational simplicity in mind, the Transient Hot Wire (THW-L2) Liquid Thermal Conductivity Meter is an advanced measurement system for direct determination of the thermal conductivity of liquids and pastes in accordance with ASTM D7896-19. In less than 2 seconds, a single measurement of small volumes of liquids and pastes can be accurately and precisely measured for thermal conductivity. Using a non-stationary measurement approach, the THW-L2 uses rapid test times to limit convective effects for samples with a wide range of viscosities. The THW sensor consists of a 60 mm heating wire that is fully inserted into an isothermal sample. A constant current source (q) is used to heat the sensor wire and the temperature rise is recorded by monitoring the change in electrical resistance of the wire. The slope (m) is determined from the plot of temperature rise vs. logarithm of time and is used in the calculation of thermal conductivity (λ). Liquid samples of high thermal conductivity will have a lower slope, while liquid samples with low thermal conductivity will have a higher slope.
-
Product
X-Band Silicon Radar Quad Core IC
AWS-0103
-
The AWS-0103 is a highly integrated silicon quad core IC intended for radar and 5G phased array applications. The device supports four radiating elements, single beam transmit, and dual beam receive and includes all requisite beam steering controls for 6 bit phase and gain control. The device provides 21 dB gain and +15 dBm output power during transmit mode and 7 dB gain and +7 dBm IIP3 during receive mode. Additional features include gain compensation over temperature, temperature reporting, and fast beam switching using eight on-chip beam weight storage registers. The device features ESD protection on all pins, operates from a +1.8V supply, and is packaged in a 56 lead 7x7 mm QFN for easy installation in planar phased array antennas.
-
Product
IEC60335-2-9 Clause 3 Figure 103 Vessel For Testing Hotplates
CX-GZ
-
Shenzhen Chuangxin Instruments Co., Ltd.
IEC60335-2-9 clause 3 figure 103 Vessel for testing hotplatesParameter:1.Pot and lid material industrial aluminum2. Pot material thickness 2 mm;3. The bottom of the pot body can not be outward convex, can not exceed 0.05mm;4. Pot body and lid surface should be smooth;5, size: 110, 145, 180, 220, 300mm each one
-
Product
Alternate 6.00 (17.00) - 2.50 (71.00) General Purpose Probe
P2662AG-2V2S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
4x IDC to 192 Pin Quadrapaddle
YAV90Q04
Interface
The interface YAV90Q04 permits to connect two YAV90096 boards to one 192-Signal contacts Quadrapaddle module. As the Mini-D 50 connectors let 2 free pins (1 and 26), these pins are interconnected to a test point, with the possibility of be grounded. Cable P/N J6200540: Mini-D-50 to Mini-D-50 IDC connectors with 400 mm flat cable.
-
Product
ATX Motherboard
-
ATX MotherboardAxiomtek's high performance industrial ATX motherboards (305 x 244 mm) support a wide range of computing capacities, rich I/Os and expansion slots. The ATX motherboards are ideal platforms for applications in digital video recorder, POS system, intelligent transportation system, multi-media center and more.
-
Product
Process Counters
TCT201-2ABC
-
The Process Counter TCT201-2ABC is a 1/16 Din 48 x 48 mm panel mount programmerable digital Counter with two 8 Amp relay outputs and up to 3 inputs. The TCT201-2ABC also has a potentiometer input that can accept either 5K or 10K Potentiometers. Other inputs can be PNP or NPN switches, 2 or 3 wire Proximity switches.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2J30
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Coaxial Waveguide Adapter, 2.4 mm (f), 26.5 to 40 GHz
R281A
Coax Adapter
The Keysight R281A adapter transforms waveguide transmission line into 50-ohm coaxial line. Power can transmitted in either direction, and each adapter covers the full frequency range of its waveguide band with SWR less than 1.3.
-
Product
Long Travel Extensometer
XL
-
The Instron model XL (long travel) extensometer is a precise device for measuring strain in highly extensible materials such as elastomers, semi-rigid plastics and films. Designed for use with electromechanical testing instruments, Instron XL units can be used to measure specimens elongation's up to 10 in or 250 mm. An optional of 15 in or 375 mm travel is also available.