Frequency Standards
Devices that produce a known frequency.
See Also: Hydrogen Frequency Standards, Rubidium Standards, GPS Clocks
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16
85038A
Mechanical Calibration Kit
The Keysight 85038A calibration kit contains open circuits, short circuits and terminations with both male and female 7-16 connectors and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25A-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-F
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
Product
Standard 1.24 (35.00) - 2.94 (85.00) Battery Probe
CCA-006
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 78Full Travel (mm): 1.98Recommended Travel (mil): 40Recommended Travel (mm): 1.02Overall Length (mil): 669Overall Length (mm): 16.99
-
Product
Xytronic Three-Phase Reference Standard +/- 0.04%, +/- 0.02%, +/- 0.01%
RADIAN RX-30, RX-31 and RX-33
-
Radian Research is committed to providing our customers with leading innovative and technologically superior products, while maintaining metrology capability in power and energy measurement that is surpassed by none. Our engineers drew on the expertise and knowledge we acquired for our industry-leading legacy RM (Metronic) and RD (Dytronic) reference standards to develop the RX (Xytronic), the ultimate in power and energy measurement technology perfection.
-
Product
High Power Frequency Converter
BL+ Series
-
Behlman's BL-PLUS Series High Power AC Source/ Frequency Converter provide the performance of a linear with all the benefits of a switching amplifier. Instead of relying on large, noisy motor generators for AC power, today's testing facilities are switching to quiet, compact Behlman AC Power frequency converters.
-
Product
Standard & Top Paint Inspection Gauges
121/4
-
is a hand-held paint gauge that offers a quick, versatile method of coating examination and measurement in a portable, easy-to-use format.
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Non Replaceable General Purpose Probe
MEP-20B
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
Product
Standard Voltage 37 Pin D-Type Cables - Calibration Cables for Pickering
-
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 37-pin D-type calibration port connector.
-
Product
WR3.4 Frequency Extension Solution, 220-330 GHz with VDI Extender Modules
CobaltFx 220 to 330 GHz
-
CobaltFx cost-effective millimeter wave frequency extension system allows you to build a scalable and affordable 5G testing solution.
-
Product
Standard Probe Station Chucks & Accessories
-
In this test solutions section of our website we describe the expanding line of Abet PV IV probe stations for the growing variety of solar cell types and sizes being developed around the world. This page describes a line of vacuum chucks and accessories for top/bottom, top/top, and bottom/bottom solar cells from 3 x 3 mm to 300 x 300 mm. Probe stations for multiple device on a single substrate and multifunction probe stations are described further in the sections highlighted to the left of this page.
-
Product
Dytronic Primary Transfer Ultra Stable Standard
RD-22 Ultra
-
The RD-22 Dytronic Primary Transfer Ultra Stable Standard represents the state-of-the-art technology in a commercially available AC transfer reference. The Ultra Stable RD-22 is a variant of the RD-22 Primary Transfer Standard that has been optimized for 120/240 V @ 5A operation to provide optimum stability. In a stable test environment, repeatability for a 10-second test of ±0.6 µWh/VAh is attained at 120 V and 240 V at 5A inputs with a 95% confidence interval. A typical experimental 2 repeatability of less than ±0.25 µWh/VAh is achieved. In a stable test environment, a reproducibility of ±2 µWh/VAh over a five-day interval is attained at 120 V and 240 V at 5A inputs with 95% confidence interval.
-
Product
Standard 0.70 (20.00) - 1.30 (37.00) Non Replaceable General Purpose Probe
A-S-R
General Purpose Probe
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 230Overall Length (mm): 5.84Rec. Mounting Hole Size (mil): 38Rec. Mounting Hole Size (mm): 0.97Recommended Drill Size: #62 or 0.97 mm
-
Product
Standard In-door Forward Optical Receiver
ONR-8636
-
Hangzhou Huatai Optic Tech. Co., Ltd.
ONR-8636 with standard configuration is a type of high index and universal in-door forward optical receiver. It adopts Philip optical receiving module. End-grade adopts power-doubling module. Optical connectors and RF connector can be installed at the front panel or back panel.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Standard Gain Horn Conical Lens antennas
-
Elva’s SLHA series of standard gain horn lens antennas cover the frequency range of 18 to 220 GHz in ten waveguide bands. They can be issued with rectangular or circular waveguide. Lens technology significantly allows decreasing mechanical sizes of horns and correcting beam for the best performance. These horns are ideal solution for measurement gain of other antennas, short range radars and radiometers.
-
Product
Frequency Multipliers
Triplers
-
*No mechanical tuners*fullband operation*planar design*zero Bias
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-2
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Pyramid, 3-Sided Chisel 30°, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0T
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Single Frequency Lasers
-
A single-frequency laser is a type of laser which operates within a singular resonator mode, achievable when the net gain bandwidth of the laser remains narrower than the frequency spacing of the resonator modes. In cases where the mode spacing isn’t adequately large to support a single resonator mode, single-frequency operation is maintained through the utilization of intracavity filters. This enables the single-frequency laser to possess an exceedingly narrow linewidth, frequently measuring only a few kHz, and an extended coherent length. A clear association exists between the coherence length and the spectral width of the laser.
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4F
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-8
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2P
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 1.09 (31.00) - 4.50 (128.00) Long Travel Bead Probe
BPLT-1HF-4.5
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
Product
Radio Frequency, Communications, & Navigation Test Systems
Test System
Reduce testing time and costs with the Astronics radio test sets for use in military, avionics, and civil security industries.Available in commercial and military grades, these integrated test systems make it easy to develop test program sets and leverage them securely and instantly across all deployed testers at the factory, depot, and operational levels.
-
Product
Standard 1.09 (31.00) - 4.50 (128.00) Long Travel Bead Probe
BPLT-1F-4.5
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
Product
AC Power Source, Frequency Converter
BL1350 Series
-
Behlman's BL1350 AC Power Supply / Frequency Converter / Inverter, requires just 3.5" of rack height, and weighs as low as 45 pounds, yet it delivers 1350 VA of quality AC power. In the BL 1350, you'll find the quality features you expect from Behlman, fully adjustable frequency and voltage, total harmonic distortion of less than 0.5%, high efficiency, plus excellent line and load regulation.
-
Product
Frontend - Frequency Extension to D-Band (110 GHz to 175 GHz)
FE170ST
-
The R&S®FE170ST is ideal for early subterahertz and 6G research. By extending the frequency ranges for the R&S®SMW200A and R&S®SMM100A to the D band (110 GHz to 175 GHz) engineers can access the range they need and develop the next generation of mobile communications. The easy-to-use, fully-calibrated solution is compatible with our signal generator, analyzer and oscilloscope environments. Plug it in and start designing the next generation of mobile communications today.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3B
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
DOUBLE FREQUENCY DOUBLE VOLTAGE TEST SET
-
International Biological Laboratories
This test set provides a continuously variable output voltage at double frequency to test the insulation between turns of coils, layer to layer, terminals of windings with either uniform or graded insulation and also between the windings and earth, with graded insulation of both Distribution and Power transformers.