Frequency Standards
Devices that produce a known frequency.
See Also: Hydrogen Frequency Standards, Rubidium Standards, GPS Clocks
-
Product
Sweep Frequency Response Analyzer
FRANEO 800
-
FRANEO 800 was developed for testing the mechanical and electrical integrity of power transformers after transportation or exposure to high fault currents. It uses the sweep frequency response analysis (SFRA) principle and measures the electrical transfer function over a wide range of frequencies.
-
Product
Standard GaN Amplifiers
-
A GaN (Gallium Nitride) amplifier is a power amplifier that uses GaN, a wide-bandgap semiconductor material, to provide high power density, efficiency, and frequency capabilities.
-
Product
Frequency Converters
-
Analytic Systems' Single and 3-Phase Sine-Wave Converters deliver output power ranging from 250 VA to 5000 VA. Our Frequency Converters also generate nominal output voltages of 115 VAC or 220 VAC, at frequencies of 50, 60 or 400 Hz. A broad range of input voltages are available.
-
Product
Oil Immersed Transfer Standard
esi SR1030 Series
-
The esi SR1030 transfer standards consist of 12 equal steps. These steps are available in increments of 1 (SR1030-1), 10 (SR1030-10), 100 (SR1030-100), 1k (SR1030-1k), 10k (SR1030-10k) and 100k (SR1030-100k). The esi SR1030 provides four-terminal connections for each step or for series and parallel combinations of these resistance steps using the optional Series-Parallel (SPC102), Parallel Compensation Networks (PC101) and shorting bars (SB103). This improves power dissipation, stability and errors due to variance in temperature. The esi SR1010 and esi SR1030 are used for the same applications and are alike in configuration. The esi SR1030 differs from the esi SR1010 in that it is specially sealed, and values below 100 k are filled with oil to improve changes due to thermal variations.
-
Product
ACCUplace Macro Calibration Standard
AP-M Series
-
With both X & Y axis metric scales, these dual axis targets are ideal for calibrating optical magnification in microscopes, linear distance, stage motion and squareness. In addition, with the larger area calibration scale, the calibration of low power optical systems over the longer distances can be easily carried out. The AP-M is offered on two standard materials; Glass (CG) and Opal (OP).
-
Product
Frequency Expansion Modules
-
bsw TestSystems & Consulting AG
Up To 1.5THz For Network Analyzers Modern communication standards, like for instance 5G, place high demands on components (mixers, amplifiers, antennas, etc.), which have to be examined in high frequency bands (millimeter waves); the requirements include: broad frequency coverage, sufficient output power to operate the components under compression, high dynamic range and stability as well as a reduced dynamic content within the spectrum.
-
Product
Standard M12 Cylindrical Photoelectric Sensors
-
Contrinex Standard M12 Cylindrical Photoelectric Sensors
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-1R1S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
Standard Tensile Link
SL-3.0
-
The SL-3.0 is a cable connected Tensile Link available with capacities ranging from 1t to 500t. These devices can be used in various tension load monitoring applications for industries worldwide and combine high levels of performance with excellent value.
-
Product
40-72 GHz Doubler
1GC1-8048
Frequency Extender
The 1GC1-8048 is a balanced diode frequency doubler consisting of two Schottky diodes and a coplanar balun structure. The doubler provides 15 dB conversion loss and 17.5 dBc 1st and 3rd order feed-thru for input frequencies between 20 and 33.5 GHz. This IC is fabricated in HFTC's InGaP/GaAs heterojunction bipolar transistor (HBT) process that provides excellent uniformity, reliability and 1/f noise performance.
-
Product
Conformance Calibration Standard Test Card for GS1-128 Symbol Verifiers
AI-CCS-128-E Rev B
-
This test card is ideal for testing of verifiers, scanners, and other GS1-128 barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.
-
Product
Portable Three-Phase Energy Standard
PEWM-3C
-
The three-phase energy standard PEWM-3C is used for quick on-site tests of all types of electricity meters – for active, reactive or apparent energy, two-, three- or four-wire connection. Three voltages and three currents are measured at the same time. The current can be measured either via direct connection up to 10A (class 0.1), or with three current clamps (CC) to 120A, 150A or 1000A (class 0.2).
-
Product
Decade Resistance Substituter Lab Standard
HARS-LX Series
-
The HARS-LX substituter is a precision resistance source with excellent characteristics of accuracy, stability, temperature coefficient, and power coefficient. All these features serve to make it a laboratory resistance standard, exceeded in performance only by stand-alone standard resistors.
-
Product
Spectral Radiance / Luminance Calibration Standards
-
Standard lamps calibrated in luminance and spectral radiance. Traceable calibrations in the wavelength range from 250 nm to 2500 nm.
-
Product
Uniformity Calibration Standards
-
Integrating sphere light sources with halogen lamps or LEDs for generating luminous fields with uniform luminance distribution. Traceable calibrations of luminance or spectral radiance in the wavelength range from 250 nm to 2500 nm.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74C
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Digital Frequency Meter
CSF-400
-
Measuring frequency. Accuracy: +/- 0.05%. 4 Digital display: 9999 Input Max. 400Hz/600 V, 30KHz/12V. Aux. Power AC 115/230V +/-15%, 50/60Hz. Isolation Aux. Power 12Vdc, 24Vdc, 48Vdc, 110Vdc available in option. Easy-to-wire, screw type terminal. Outside dimensions is DIN standard (96mm x 48mm) High stability & low cost.
-
Product
Time & Frequency Distribution Amplifiers
-
Brandywine offers a wide range of high quality, state of the art signal timing distribution amplifiers, all with very low phase noise. These precision timing signal distribution amplifiers offer a variety of time and frequency signals and interface formats including IRIG A, IRIG B, Have Quick, 1PPS, as well as low phase noise reference frequencies. All of our distribution amplifiers feature dual inputs with automatic failover and multiple independently buffered outputs.
-
Product
Innovative Open Standard
PROFINET
-
PROFINET is the innovative open standard for Industrial Ethernet, development by Siemens and the Profibus User Organization (PNO). With PROFINET, solutions can be implemented for factory and process automation, for safety applications, and for the entire range of drive technology right up to clock-synchronized motion control. PROFINET is standardized in IEC 61158 and IEC 61784. Profinet products are certified by the PNO user organization, guaranteeing worldwide compatibility.
-
Product
Airborne Frequency Converter
AFC Series
-
Behlman’s AFC-7000-1 & -2 and AFC-7003, frequency converter are designed to convert three-phase aircraft power to regulated single-phase (115 or 230 VAC) or three-phase (115/200 VAC) at 50 Hz, 60 Hz or 400 Hz. They are ruggedly built to support aircraft takeoffs and landings and designed to meet the input power requirements of MIL-STD-704 and RTCA-DO-160.
-
Product
Series Low Frequency Vibration Sensors
AC136
-
Low Frequency Accelerometer, Side Exit Connector / Cable, 500 mV/g
-
Product
Single Frequency CW 532 NM Laser up to 18W
EQUINOX
-
Equinox is a single frequency, 532 nm continuous wave laser designed for a range of scientific applications including pumping any Ti:Sapphire laser systems. It is engineered to meet the needs of experimentalists requiring high-performance systems with an emphasis on reliability, stability and ease of use. The laser incorporates pump diodes within the central unit and is fully automated with hands-free operation and control via ethernet, webpage and TCP/IP remote interface. This completely sealed system is inherently stable with low noise levels <0.05 % RMS and ultra-stable output powers with ±0.5 % stability. Equinox has options of high output power up to 18 W. Other major applications include mixing source, pump source for dye lasers and frequency doublers, optical tweezers, and biomedical imaging.
-
Product
Audio Frequency Generator
TM530
-
TM530 Audio Frequency Generator is provided with Pinpoint Fault Locator for pinpointing the low resistance fault and detecting cable route. When detecting, TM530 will inject a signal current of 1kHz audio frequency into the cable, and accordingly a magnetic wave of the corresponding frequency will be generated on the cable. Pinpoint Fault Locator will collect this magnetic signal, thus obtains the information of the cable fault and the route.
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4E
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3L5
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard - 5.00 (142.00) - 8.30 (235.00) Feed Through Probe
P3325-0
-
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 645Overall Length (mm): 16.38
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2G30
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
NanoLattice Pitch Standard (NLSM)
-
The NanoLattice™ (NLSM) 100 nm pitch standard utilizes gratings with near perfect periodicity to calibrate magnification and scan linearity of CD-SEM and Atomic Force Microscopes (AFM). Make the grade, with the only pitch standard of its kind available below the 130 nm node.
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-1C1S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)