Temperature Recorders
Record the measurement of heat or cold.
See Also: Recorders, XY Recorders, Chart Recorders, Fault Recorders, Disturbance Recorders, High Speed Data Recorders, Event Recorders, Transient Recorders, Data Recorders
-
product
Temperature Logger-30 to +50C
TV-4050
This data logger is a self-contained temperature recorder with a digital display. The TV-4050 is ideal for monitoring the temperature of offices, cold storage rooms, museum exhibits and many other applications where a visual temperature indication is needed.
-
product
Temperature/Humidity/Dew Point Circular Chart Recorder
The Temperature/Humidity/Dew Point Circular Chart Recorder uses a red pen to track temperature and a blue pen to track humidity, permanently recording these measurements on a 6-inch (165mm) diameter paper chart. Power is supplied to the temperature recorder through a 110V AC 50/60 Hz plug-in adapter for Model 14013 and a 220V AC adapter for Model 14014. External power may be supplied from any 12V DC source such as automotive, marine or other battery.
-
product
Compact USB Data Logger with Display
DW-USB-LCD
The Portable Series DW-USB-LCD USB Data Loggers displays and records temperature, humidity and dew point. The easy-to-read LCD display shows the current temperature or humidity along with the minimum and maximum reading since last reset. For applications that require more accuracy, a high accuracy temperature and humidity model is available. Thermocouple models can accept any J, K, or T type thermocouple with a mini-plug connector.
-
product
Temperature Data Logger
TGU-4017
Self-contained temperature recorder Delayed start option 32,000 readings capacity High accuracy and reading resolution Fast data offload Splashproof case Low battery monitor User-replaceable battery USB or serial download cables User-programmable alarms
-
product
Thermal Data Logger
51101 Series
It is a general requirement to record temperatures, voltages, currents, and many physics quantities during research, product development, productions, and quality assurance processes. The number of record channels can be a simple one to several complicated set of hundreds. Thermal/multi-function data loggers are prefect solutions to serve for these measurement and tracking needs.
-
product
Configurable System For Temperature Measurement With CAN FD Interface
MU thermocouple1 CAN FD
With the MU-Thermocouple1 CAN FD, measurement data from thermocouples are recorded, pre-processed and transmitted with CAN FD. The temperature is measured via 8 connections, which are designed for the temperature measuring ranges J, K or T, depending on the product version. Temperatures can be recorded in Celsius, Fahrenheit or Kelvin and calculated with an individual factor and offset. The measurement data is then transmitted via CAN FD or via classic CAN.
-
product
In-Transit Temperature Chart Recorder
DeltaTrak's In-Transit Temperature Chart Recorder, Model 16000-16502, is a highly reliable, time and temperature strip chart recorder used to record environmental conditions encountered during storage and transportation of food, pharmaceuticals, chemicals, and other temperature-sensitive commodities in refrigerated trucks, rail cars, ocean and air freight containers.
-
product
Dual Channel Temperature/Relative Humidity
TGP-4500
This unit records temperature and humidity using self-contained sensors. It can record temperatures between -25 and +85C and relative humidity between 0 to 100%. The unit is waterproof, so it can be used outside.
-
product
Temperature Data Logger
TG-4080
The Tinytag Transit 2 logger, TG-4080, is a practical, robust, lightweight and cost effective temperature recorder ideal for monitoring goods in transit such as foods, pharmaceuticals and other temperature-sensitive products.
-
product
Temperature Data Logger
DL001
Record temperature in a wide range of applications including HVAC testing and balancing, transportation, and energy management with the Model DL001 Temperature Data Logger. Temperature logger has an on-board thermistor and an external sensor channel for remote temperature measurements
-
product
Electronic Circular Temperature Chart Recorder
The Circular Temperature Chart Recorder’s external stainless steel probe allows you to measure the temperature of air, gas, liquids and semi-solids. The temperature chart recorder has a quartz clock movement, motorized chart advance and temperature accuracy of ±2°F (±1°C). The chart recorder comes in °F or °C models and runs on 120V or 220V AC, 50/60 Hz. A rear compartment houses 8 AA alkaline batteries, providing up to 48 hours of continuous recording in the event of a temporary power loss.
-
product
High-Performance Handheld Infrared Camera
FLIR T865
The FLIR T865 thermal imaging camera is a non-contact inspection tool with 180° rotating optical block that allows users to safely and comfortably assess the condition of critical electrical and mechanical equipment in utility and manufacturing applications. With advanced features including unmatched temperature measurements down to -40°C, accuracy as good as 1°C/1%, 1-Touch Level/Span contrast enhancement, and laser–assisted autofocus, you'll get highly accurate temperature measurements every time. Pair the T865 with a 6 FOV IR lens to perform inspections on small targets from long distances. The on-board Inspection Route system helps you record temperature data and imagery in a logical sequence for faster troubleshooting and repair. The T865 also features FLIR Ignite for automatic uploading of images directly from the camera to the cloud for easy, secure storage and sharing. Adding a FLIR T865 camera to a condition monitoring/predictive maintenance program can help reduce maintenance costs, improve system efficiency and reliability, and prevent downtime due to outages.
-
product
Professional Thermal Camera
FLIR T540
Diagnose potential faults in industrial, electrical, and mechanical systems, or discover temperature anomalies in R&D testing with the 464 × 348 resolution FLIR T540. This portable, ergonomic thermal camera offers advanced features like 1-Touch Level/Span and continuous laser-assisted autofocus, making it the perfect non-contact diagnostic tool for condition monitoring and research applications. Streamline electrical/mechanical surveys, troubleshooting, and repairs with Inspection Route mode, which runs pre-planned routes created in FLIR Thermal Studio Pro (Route Creator plugin required) so users can record temperature data and imagery in a logical sequence. The built-in Macro Mode allows R&D users to quickly switch from wide angle to close-up analysis without changing the lens. When coupled with Research Studio software, the T540 helps engineers assess unexpected hot spots and find potential design flaws. The T540 also features FLIR Ignite for automatic uploading of images directly from the camera to the cloud for easy, secure storage and sharing. The purchase of a T540 camera includes a 3-month subscription to FLIR Thermal Studio Pro and FLIR Route Creator.
-
product
Temperature and Humidity Data Logger
U3121M
The Datalogger is designed to record temperature and humidity from expternal probe. In case of exceeded set limits, SMS and JSON messages can be sent via GPRS data connection. It is possible to set the regular sending of JSON messages to Comet Database, the sending interval is adjustable.The recording is performed in a non-volatile electronic memory. The data can be transferred to a PC via USB-C.
-
product
Temperature and Humidity Data Logger
U3120M
The Datalogger is designed to record temperature and humidity humidity. In case of exceeded set limits, SMS and JSON messages can be sent via GPRS data connection. It is possible to set the regular sending of JSON messages to Comet Database, the sending interval is adjustable.The recording is performed in a non-volatile electronic memory. The data can be transferred to a PC via USB-C.
-
product
Clamp-on Testers
With our 16 models of different clamp-on testers, Yokogawa provides the right tool for the job. Our CL Series consists of AC, AC/DC, and leakage current clamps with various ranges and dimensions. The multiple options include RMS, Mean, Temperature, frequency, and recorder output.
-
product
Pocket-size temperature logger
DEFI2-T
DEFI2-T is a high-precision miniature water temperature recorder for long-term observations (approx. 573 days for 1 minute interval observation). The reduced size of the DEFI2-T allows the device to be installed in large numbers in a single mooring system, allowing investigating temperature fluctuations at increased spatial resolution. Also, AAA alkaline batteries used by DEFI2-T are easily available, reducing the operating costs.
-
product
FD-11613, 8-Channel Temperature Input Device for FieldDAQ
785640-01
8-Channel Temperature Input Device for FieldDAQ - The FD-11613 measures up to eight thermocouple channels. It features cold-junction compensation and open thermocouple detection with an LED indicator per channel to identify disconnected thermocouples. The FD-11613 has an ingress … protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11613 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11613 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. This device is ideal for test cell and outdoor environments.
-
product
REM-11120, 4-Channel Thermocouple, 1-Channel Voltage, Temperature Input Module for Remote I/O
784750-01
4-Channel Thermocouple, 1-Channel Voltage, Temperature Input Module for Remote I/O - The REM‑11120 is a temperature input module for remote I/O. Remote I/O systems are low-cost, modular systems for simple machine control and measurements. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the REM‑11120 from a real-time controller such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low-cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high-speed or specialty measurements. The REM‑11120 also has an adjustable filter time for improved measurement quality and optional external cold junction compensation (CJC) or PT100 resistance temperature detector (RTD) measurements.
-
product
USB-TC01, 1-Channel Temperature Input Device
781314-01
The USB‑TC01 is a thermocouple measurement device featuring InstantDAQ technology. InstantDAQ technology includes built-in software for viewing and logging data that automatically loads when you plug in the device, so you can instantly take … temperature measurements with your PC. You can connect the USB‑TC01 to any USB port to use your PC as a display and monitor data in real time. The USB‑TC01 is compatible with J, K, R, S, T, N, E, and B thermocouples.
-
product
NI-9210, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module
784788-01
4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The NI‑9210 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9210 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
product
NI-9214, 16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module
781510-01
16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module - The NI‑9214 is a high-density thermocouple input module that is designed for higher channel count systems. The NI‑9214 includes features to increase overall accuracy, such as CJC sensors in the terminal block, component layout to minimize thermal gradients, and an autozero channel for offset error compensation.
-
product
NI-9217, 4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
779592-01
4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9217 is a resistance temperature detector (RTD) input module. You can configure the NI‑9217 for two sample rate modes: high sample rate or high resolution. The NI‑9217 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9217 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-01
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
product
FD-11614, 16-Channel Temperature Input Device for FieldDAQ
785854-01
The FD-11614 measures up to 16 thermocouple channels. It features cold-junction compensation and open thermocouple detection with an LED indicator per channel to identify disconnected thermocouples. The FD-11614 has an ingress … protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11614 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11614 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. This device is ideal for test cell and outdoor environments.
-
product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
785189-01
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
NI-9210, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module
785043-01
4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The NI‑9210 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9210 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-01
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-02
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.





























