Transient Recorders
Record signal faults that are self rectifying.
See Also: Recorders, XY Recorders, Chart Recorders, Fault Recorders, Disturbance Recorders, High Speed Data Recorders, Event Recorders, Temperature Recorders, Data Recorders, Digital Fault Recorders
-
Product
PCIe-6376, 8 AI (16-Bit, 3.5 MS/s/ch), 2 AO, 24 DIO, Multifunction I/O Device
785809-01
Multifunction I/O
8 AI (16-Bit, 3.5 MS/s/ch), 2 AO, 24 DIO, Multifunction I/O Device - The PCIe‑6376 is a simultaneous sampling, multifunction DAQ device. It offers analog I/O, digital I/O, four 32‑bit counters, and analog and digital triggering. Onboard NI‑STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The PCIe‑6376 is ideal for a variety of applications, such as IF digitization; transient recording; ISDN, ADSL, and POTS manufacturing test in the telecom industry; ultrasound and sonar testing; and high-energy physics. The included DAQExpress™ companion software provides basic measurement and analysis, while the NI‑DAQmx driver provides the ability to create customized automated measurement and control applications.
-
Product
HandyScope HS5: 200 MS/s 250MHz BW, 2 Channel, USB Digital Storage Oscilloscope, 20MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder
HS5-220XM-W5
-
The Handyscope HS5 is the first USB oscilloscope (USB powered) sampling at 200 MHz, with a 14 bits resolution and a 250 MHz bandwidth. This makes it possible to analyze very fast signals with very small amplitudes. The smallest distortions can be revealed due to the high resolution and bandwidth. Because of the deep memory (up to 64 MSamples on one channel), long record measurements are available for intermittent phenomena and Fast Fourier Transform calculations with over 32 million spectral lines can be performed. Using very fast FFT algorithms, an FFT with 1 million spectral lines can be performed within a second.
-
Product
HandyScope HS6-DIFF With EMI, SureConnect & SafeGround: 1 GS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-1000XMEGS-W
-
The powerful capabilities of the WiFiScope HS6-DIFF-1000XMEGS EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.
-
Product
HandyScope HS3: 50 MS/s 100MHz BW, 2 Channel, USB Digital Storage Oscilloscope, AWG, Spectrum Analyzer, Voltmeter, Transient Recorder
HS3-50
-
The Handyscope HS3 is a powerful computer controlled measuring instrument that consists of four measuring instruments: a Voltmeter, Oscilloscope, Spectrum analyzer and Transient recorder. Also an AWG (Arbitrary Waveform Generator) is available. This new powerful and compact measuring instrument can solve almost every measurement problem.
-
Product
PCI-6123, 8 AI (16-Bit, 500 kS/s/ch), 8 DIO, PCI Multifunction I/O DeviceMultifunction I/O Device
779409-01
Multifunction I/O
8 AI (16-Bit, 500 kS/s/ch), 8 DIO, PCI Multifunction I/O Device - The PCI‑6123 is a simultaneous-sampling, multifunction DAQ device. It offers analog input, digital I/O, two 24‑bit counters, and digital triggering. The PCI‑6123 is ideal for a variety of applications, such as IF digitization; transient recording; ISDN, ADSL, and POTS manufacturing test in the telecom industry; ultrasound and sonar testing; and high-energy physics. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements. The PCI‑6123 dimensions require chassis slots that can accommodate full-length PCI modules.
-
Product
Multi-Function Transient Fault Recorder
TR-3000
-
The TR-3000 is the only tool you need to capture and diagnose power system anomalies. With multiple recording modes and continuous transient oscillography, you will never miss an event. The TR-3000 captures high speed transients and long term system disturbances with enough memory to give you a complete view of the system disturbance. The TR-3000 takes the place of several devices: • Fault and Disturbance Recorder • Transient Fault Location • Phasor Measurement Unit • Power Quality Monitor • Sequence of Events Recorder.
-
Product
Overview About LAN Ethernet Transient-Recorders / Digitizer
-
The GaGe FCiX Cobra/CobraMax LAN digitizer features 2 channels of 8-bit resolution with a maximum sampling rate up to 2 or 4 GS/s for one channel and up to 1 or 2 GS/s for two channels and true Effective Number of Bits (ENOB) up to 7.6-bits with 10 MHz input.
-
Product
PXIe-6124, 4 AI (16-Bit, 4 MS/s/ch), 2 AO, 24 DIO, PXI Multifunction I/O Module
780536-01
Multifunction I/O
PXIe, 4 AI (16-Bit, 4 MS/s/ch), 2 AO, 24 DIO, PXI Multifunction I/O Module—The PXIe‑6124 is a simultaneous sampling, multifunction DAQ device. It offers analog I/O, digital I/O, two 32‑bit counters, and analog and digital triggering. The PXIe‑6124 is ideal for a variety of applications, such as IF digitization; transient recording; ISDN, ADSL, and POTS manufacturing test in the telecom industry; ultrasound and sonar testing; and high-energy physics. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
WiFiScope WS5: 200 MS/s 250MHz BW, 2 Channel, Digital Storage Oscilloscope, 20MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder
WS5-220XM-W5
-
TiePie engineering has introduced the WiFiScope series oscilloscopes. The new range WiFi oscilloscopes can be used via an ethernet connection (LAN, WiFi or WAN) but also still with a USB 2.0 / 3.0 connection. The built-in battery gives the WiFiScope the possibility to perform fully wireless measurements. Measurements can then be performed completely galvanically isolated, and over long distances. This wireless PC-based data acquisition instrument offers the user more possibilities for measurement applications.With a WAN connection, worldwide measurements can be performed. Specific knowledge on networks is not required. The Multi Channel software gives an overview of the available USB instruments and network instruments. Simply tick the instrument and measuring can start. The WiFi oscilloscope has the following advantages: fully wireless measurements via WiFi are performed (galvanically isolated) because of the built-in battery mobile measurements are possible, e.g. on transport systems and moving installations LAN and WAN data acquisition is available for long distance measurements continuous realtime highspeed data acquisition over both WiFi and LAN/WAN are available USB measurements for stand-alone applications and highspeed data acquisition up to 200MSa/s.
-
Product
PXIe-6376, 8 AI (16-Bit, 3.5 MS/s/ch), 2 AO, 24 DIO, PXI Multifunction I/O Module
781475-01
Multifunction I/O
PXIe, 8 AI (16-Bit, 3.5 MS/s/ch), 2 AO, 24 DIO, PXI Multifunction I/O Module—The PXIe‑6376 is a simultaneous sampling, multifunction DAQ device. It offers analog I/O, digital I/O, four 32‑bit counters, and analog and digital triggering. Onboard NI‑STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The PXIe‑6376 is ideal for a variety of applications, such as IF digitization; transient recording; ISDN, ADSL, and POTS manufacturing test in the telecom industry; ultrasound and sonar testing; and high-energy physics. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
WiFiScope WS6+SureConnect+EMI: 1 GS/s 250MHz BW, 4 Channel, Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
WS6-1000XMES-W5
-
TiePie engineering has introduced the WiFiScope series oscilloscopes. The new range WiFi oscilloscopes can be used via an ethernet connection (LAN, WiFi or WAN) but also still with a USB 2.0 / 3.0 connection. The built-in battery gives the WiFiScope the possibility to perform fully wireless measurements. Measurements can then be performed completely galvanically isolated, and over long distances. This wireless PC-based data acquisition instrument offers the user more possibilities for measurement applications.
-
Product
HandyScope HS6-DIFF With SafeGround & SureConnect: 500 MS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-500XMSG-W5
-
The only oscilloscope in the world that has:- SafeGround, differential input channels that can be switched to single ended.-SureConnect, auto-detects a true connection between the probe tip and the device under test.- CMI interface.- USB 3.0 interface, 5Gb/s data transfer- Lowest noise
-
Product
HandyScope HS6-DIFF With SafeGround: 200 MS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-200XMG-W5
-
- 1GS/s sampling and flexible resolution of 8-16 bit.- Four input channels up to 250 MHz analog bandwidth- Highly accurate 1 ppm time base- DC Accuracy of 0.25 % and 0.1 % typical- Very fast 200 MSamples per second USB streaming Data logger- Spectrum analyzer with 32 million bins- Optional SureConnect connection test on all channels- Up to 256 MSamples memory per channel
-
Product
Premium Automotive DMM
597
-
*CATIII 1000 Volt / CATIV 600 Volt Approved & Safety Rated *Safe For Use on Hybrids and EV's *Highest Quality Auto-Ranging DMM Designed for Automotive Trouble Shooting *18 Test Functions, 48 Test Ranges *Peak Min/Max records transient voltages as fast as 1 millisecond *Min/Max Mode records variations in all functions *Also measures Temperature via Temp Probe in Both F and C *Milliseconds Pulse Width Measures Fuel Injector ON-TIME *Inductive RPM Readings for both DIS and Conventional Ignitions *Desirable 20 Amp Test Range - Dual Fuse Protection *Modern Design, the Protective Holster is Built Into the Housing *Data Hold, Auto Power-Off, + Trigger Adjust *Large LCD Display w/White LED Backlighting and 40 Segment Analog Bargraph *Blow Mold Case, Test Leads, K-Type Temp Probe, Inductive RPM Clamp and Instructions included *Waterproof to IP67 Standards
-
Product
HandyScope HS3: 100 MS/s 100MHz BW, 2 Channel, USB Digital Storage Oscilloscope, AWG, Spectrum Analyzer, Voltmeter, Transient Recorder
HS3-100
-
The Handyscope HS3 is a powerful computer controlled measuring instrument that consists of four measuring instruments: a Voltmeter, Oscilloscope, Spectrum analyzer and Transient recorder. Also an AWG (Arbitrary Waveform Generator) is available. This new powerful and compact measuring instrument can solve almost every measurement problem.
-
Product
HandyScope HS3: 10 MS/s 100MHz BW, 2 Channel, USB Digital Storage Oscilloscope, AWG, Spectrum Analyzer, Voltmeter, Transient Recorder
HS3-10
-
The Handyscope HS3 is a powerful computer controlled measuring instrument that consists of four measuring instruments: a Voltmeter, Oscilloscope, Spectrum analyzer and Transient recorder. Also an AWG (Arbitrary Waveform Generator) is available. This new powerful and compact measuring instrument can solve almost every measurement problem.
-
Product
HandyScope HS6-DIFF With SureConnect: 100 MS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-100XMS-W5
-
- 1GS/s sampling and flexible resolution of 8-16 bit.- Four input channels up to 250 MHz analog bandwidth- Highly accurate 1 ppm time base- DC Accuracy of 0.25 % and 0.1 % typical- Very fast 200 MSamples per second USB streaming Data logger- Spectrum analyzer with 32 million bins- Optional SureConnect connection test on all channels- Up to 256 MSamples memory per channel
-
Product
HandyScope HS6-DIFF: 1 GS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-1000XM-W5
-
*The only oscilloscope in the world that has:-* SafeGround, differential input channels that can be switched to single ended.*- CMI interface.*- USB 3.0 interface, 5Gb/s data transfer*- Lowest noise
-
Product
HandyScope HS6-DIFF With SureConnect: 200 MS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-200XMS-W5
-
- 1GS/s sampling and flexible resolution of 8-16 bit.- Four input channels up to 250 MHz analog bandwidth- Highly accurate 1 ppm time base- DC Accuracy of 0.25 % and 0.1 % typical- Very fast 200 MSamples per second USB streaming Data logger- Spectrum analyzer with 32 million bins- Optional SureConnect connection test on all channels- Up to 256 MSamples memory per channel
-
Product
PXIe-6386, 8 AI (16-Bit, 14 MS/s/ch), 2 AO, 24 DIO, PXI Multifunction I/O Module
785926-01
Multifunction I/O
PXIe, 8 AI (16-Bit, 14 MS/s/ch), 2 AO, 24 DIO, PXI Multifunction I/O Module - The PXIe-6386 is a simultaneous sampling, multifunction DAQ device. It offers analog I/O, digital I/O, four 32‑bit counters, and analog and digital triggering. Onboard NI-STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The PXIe-6386 is ideal for a variety of applications, such as IF digitization; transient recording; ISDN, ADSL, and POTS manufacturing test in the telecom industry; ultrasound and sonar testing; and high-energy physics. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
HandyScope HS5 + SureConnect: 50 MS/s 250MHz BW, 2 Channel, USB Digital Storage Oscilloscope, 5MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder
HS5-055XMS-W5
-
The Handyscope HS5 is the first USB oscilloscope (USB powered) sampling at 50 MHz, with a 14 bits resolution and a 250 MHz bandwidth. This makes it possible to analyze very fast signals with very small amplitudes. The smallest distortions can be revealed due to the high resolution and bandwidth. Because of the deep memory (up to 64 MSamples on one channel), long record measurements are available for intermittent phenomena and Fast Fourier Transform calculations with over 32 million spectral lines can be performed. Using very fast FFT algorithms, an FFT with 1 million spectral lines can be performed within a second.
-
Product
HandyScope HS6-DIFF: 200 MS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-200XM-W5
-
The only oscilloscope in the world that has:- SafeGround, differential input channels that can be switched to single ended.- CMI interface.- USB 3.0 interface, 5Gb/s data transfer- Lowest noise
-
Product
WiFiScope WS6: 200 MS/s 250MHz BW, 4 Channel, Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
WS6-200XM-W5
-
*Oscilloscope / Spectrum analyzer / Voltmeter*14 bit (0.006 %) resolution (16 bit enhanced resolution)*200 MS/s sampling*250 MHz bandwidth*Up to 64 MSamples memory per channel*0.25 % DC vertical accuracy*1 ppm timebase accuracy*WiFiScope advantages
-
Product
HandyScope HS5: 500 MS/s 250MHz BW, 2 Channel, USB Digital Storage Oscilloscope, 40MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder
HS5-540XM-W5
-
The Handyscope HS5 is the first USB oscilloscope (USB powered) sampling at 500 MHz, with a 14 bits resolution and a 250 MHz bandwidth. This makes it possible to analyze very fast signals with very small amplitudes. The smallest distortions can be revealed due to the high resolution and bandwidth. Because of the deep memory (up to 64 MSamples on one channel), long record measurements are available for intermittent phenomena and Fast Fourier Transform calculations with over 32 million spectral lines can be performed. Using very fast FFT algorithms, an FFT with 1 million spectral lines can be performed within a second.
-
Product
HandyScope HS6-DIFF With SureConnect: 500 MS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-500XMS-W5
-
The only oscilloscope in the world that has:- SafeGround, differential input channels that can be switched to single ended.SureConnect, auto-detects a true connection between the probe tip and the device under test.- CMI interface.- USB 3.0 interface, 5Gb/s data transfer- Lowest noise
-
Product
HandyScope HS5 + SureConnect: 500 MS/s 250MHz BW, 2 Channel, USB Digital Storage Oscilloscope, 40MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder
HS5-540XMS-W5
-
The Handyscope HS5 is the first USB oscilloscope (USB powered) sampling at 500 MHz, with a 14 bits resolution and a 250 MHz bandwidth. This makes it possible to analyze very fast signals with very small amplitudes. The smallest distortions can be revealed due to the high resolution and bandwidth. Because of the deep memory (up to 64 MSamples on one channel), long record measurements are available for intermittent phenomena and Fast Fourier Transform calculations with over 32 million spectral lines can be performed. Using very fast FFT algorithms, an FFT with 1 million spectral lines can be performed within a second.
-
Product
100MS/s 100MHz BW LPT/parallel Port 2-Channel Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder, AWG/Function Generator
HS801-AWG
-
The HS801: the first 100 MSPS measuring instrument that consists of an Arbitrary Waveform Generator/Function Generator, a Voltmeter, a Digital Storage Oscilloscope (DSO), a Spectrum analyzer, and a Transient Recorder. This new portable and compact measuring instrument can solve almost every measurement problem. Analyzing signals is done with 8-bit resolution and a maximum sampling speed of 100 MHz. The input range is 0.1 Volt full scale to 80 Volt full scale. The record length is 32K/64K samples.
-
Product
HandyScope HS6-DIFF With EMI & SafeGround: 1 GS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-1000XMEG-W5
-
The powerful capabilities of the WiFiScope HS6-DIFF-1000XMEG EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.
-
Product
PXIe-6356, 8 AI (16-Bit, 1.25 MS/s/ch), 2 AO, 24 DIO, PXI Multifunction I/O Module
781053-01
Multifunction I/O
PXIe, 8 AI (16-Bit, 1.25 MS/s/ch), 2 AO, 24 DIO, PXI Multifunction I/O Module—The PXIe‑6356 is a simultaneous-sampling, multifunction data acquisition device. It offers analog I/O, digital I/O, four 32‑bit counters, and analog and digital triggering. Onboard NI‑STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The PXIe‑6356 is ideal for a variety of applications, such as IF digitization; transient recording; ISDN, ADSL, and POTS manufacturing test in the telecom industry; ultrasound and sonar testing; and high-energy physics. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
PXIe-6368, 16 AI (16-Bit, 2 MS/s/ch), 4 AO, 48 DIO, PXI Multifunction I/O Module
781058-01
Multifunction I/O
PXIe, 16 AI (16-Bit, 2 MS/s/ch), 4 AO, 48 DIO, PXI Multifunction I/O Module—The PXIe‑6368 is a simultaneous sampling, multifunction DAQ device. It offers analog I/O, digital I/O, four 32‑bit counters, and analog and digital triggering. Onboard NI‑STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The PXIe‑6368 is ideal for a variety of applications, such as IF digitization; transient recording; ISDN, ADSL, and POTS manufacturing test in the telecom industry; ultrasound and sonar testing; and high-energy physics. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.