PD Calibrators
-
Product
Photometric Ozone Calibrator
Model T703
-
Teledyne Advanced Pollution Instrumentation
The Model T703 is a microprocessor controlled ozone calibrator for precision gas analyzers. The Model T703 can deliver concentrations from 50 ppb to 5 ppm at flows from 1 LPM to 5 LPM.The Model T703 has two major components; the ozone generating device and the photometer. The ozone generator produces ozone by passing zero air over a UV lamp. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperate and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703, covering time periods up to a year.
-
Product
Bench Power Supply, Calibrated w/Data, Adjustable, 1 Output, 0 V, 30 V, 0 A, 5 A
72-2690 CAL D
-
The 72-2690 CAL D from Tenma is a single channel adjustable bench top power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has complete digital control, intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +20mV (voltage), ≤0.5% +10mA (current).
-
Product
Pt100 Temperature Transmitter PC Programmable With Push Button Calibration
SEM1605/P -
-
SEM1605/P - Pt100 Temperature Transmitter PC Programmable With Push Button Calibration
-
Product
Open-Short-Load RF calibration kits
-
Open-Short-Load RF calibration kits from Fairview Microwave are available with Type N or 7/16 DIN connectors. Type N open-short-load RF calibration kits have male or female genders, 7/16 DIN open-short-load kits are male gender. Type N open-short-load (OSL) calibration kits for RF have a minimum frequency of 0 (DC) and a maximum frequency range between 4 GHz and 6 GHz. Type N open short load kits for calibration have a maximum power handling of between 1 Watt and 2 Watts.
-
Product
Vibration Calibrator
SV 111
-
SV 111 vibration calibrator is the State of the Art instrument designed for human vibration measurements according to ISO 8041. The design of the calibrator is based on the triaxial reference accelerometer and microprocessor controlled shaker. These both features assure excellent stability of the calibration levels and their frequency independently from mass of the testing object, like also indicate improper test object fixing by monitoring of shaker vibration in all three axis simultaneously.
-
Product
Accredited Humidity Calibration Services
-
Thunder Scientific's calibration laboratory is accredited by NVLAP (National Voluntary Laboratory Accreditation Program), Certificate of Accreditation No. 200582-0 to ISO/IEC 17025 and ANSI/NCSL Z540-1 1994.
-
Product
Trace-Level Dilution Calibrator
Model T700U
-
Teledyne Advanced Pollution Instrumentation
The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements. The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.
-
Product
Temperature Calibration
-
Process Instruments maintains primary temperature standards for the calibration of Standard Platinum Resistance Thermometers. SPRT''s are measured against a Thomas-type Ten Ohm Standard Resistor (a Leeds & Northrup 4211-B), using a Measurements International automated bridge. Primary thermometry points are maintained at the Water, Tin, Zinc and Gallium points.
-
Product
Velocity Calibration
-
Trescal provides full Velocity Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Velocity Calibration services can be delivered at your site or at our lab. Accreditations for our velocity calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Temperature Calibration
-
Trescal provides full Temperature Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Temperature Calibration services can be delivered at your site or at our lab. Accreditations for our temperature calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Instrument Transformer Calibrators
MRL 11
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Automatic measure of contact resistance. True 4 terminal measurement. μP operated, automatically saves results.
-
Product
ATE / Bench Calibrators & Multimeters
-
Time Electronics offer a range of precision calibrators and digital multimeters that can be used in the lab or in automated testing applications. These programmable instruments are designed for precision, performance, and functionality, making them ideal for automatic testing and fault diagnosis. Each designated ATE calibrator is rack mountable for straightforward integration into user systems.
-
Product
Temperature Calibrator
Model KM-CAL-906
-
Kusam Electrical Industries Limited
This temperature Calibrator gives high accuracy of 0.02% for measure and source. It has dual display, 5 digits for measure and 6 digits for source & white LED for backlight. Volts, RTD & Thermocouple. It gives output up to 500W to 5kW and output for calibrating R, S, K, E, J, T, N, B, L, U type of Thermocouples RTD & Continuity.
-
Product
PD free AC Hipot Test Set
FPA Series
-
FPA Series test sets perform field or factory testing on larger electrical apparatus, including motors & generators, switchgear, bushings, bus duct, etc. This series offers the higher kVA ratings needed (0-6/12 kV AC @ 6 kVA), but is still packaged for portability.
-
Product
EMC Calibration
-
Trescal provides full EMC Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. EMC Calibration services can be delivered at your site or at our lab. Accreditations for our emc calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Temperature Calibrators
-
Ensuring process temperature accuracy involves calibrating not only the system’s electronic temperature signals, but also the very temperature sensors that initiate those signals. Rugged Fluke handheld temperature calibrators source and measure RTDs and thermocouples, power transmitters, and store data. Fluke Calibration temperature sources cover temperatures from -45 °C to 1200 °C and include handheld, portable, and benchtop calibrators. Infrared thermometer calibrators and reference measurement thermometers ensure every necessary tool is available to you.
-
Product
Deskew Calibration Source for CP030, CP030A, CP031, CP031A, AP015, CP150, CP500
DCS025
-
The DCS025 Deskew Calibration Source generates time-aligned voltage and current pulses for precise deskew of voltage and current probes.This is critical for measurements in which small propagation delay differences between probes can have a large impact on a calculated measurement, e.g., instantaneous power semiconductor device loss measurements.
-
Product
NIST Calibration for D610-A
D610-A-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Calibrators
-
Thermocouple temperature calibrator is capable of measuring and simulating up to 8 types of thermocouples (J, K, T, E, R, S, B, N), as well as a voltage in mV.
-
Product
Automated Calibration
ORION
-
ORION automates the process of characterization and calibration of engines. It facilitates the calibration process by taking control of both the ECU calibration system and the test cell control system to run experiments as part of an automated calibration process. With connectivity to IAV’s EasyDOE, Mathworks’ MBC Toolbox and other DOE tools, ORION provides an extremely powerful environment for mapping an engine and generating the Engine Management System calibration tables. The modular design means the product can be configured to a users’ specific requirements and work practices, rather than having to adhere to rigid methodologies dictated by prescriptive software.
-
Product
Bench Power Supply, Calibrated, Adjustable, 1 Output, 0 V, 30 V, 0 A, 5 A
72-2690 CAL
-
The 72-2690 CAL from Tenma is a single channel adjustable bench top power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has complete digital control, intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +20mV (voltage), ≤0.5% +10mA (current).
-
Product
Partial Discharge Pulse Calibrator
TPK
-
Partial discharge puls calibrator TPK is a battery-powered handheld device for determining the correction factor in a Partial Discharge test circuit and to verify the Partial Discharge measurement.
-
Product
Barcode Conformance Calibration Standards
-
Barcode symbol quality has been at the forefront of discussion among practitioners in the automatic identification and data capture (AIDC) industry since they were invented in 1951. Barcodes became commercially successful when they were used to automate checkout systems at grocery stores, with the very first scanning of the Universal Product Code (UPC) on a pack of Wrigley Company chewing gum in June 1974. The Uniform Code Council (UCC) published barcode quality guidelines, and ANSI X3.182-1990 became the first published standard for barcode quality. Since then, ISO/IEC 15416 for 1D symbols and ISO/IEC 15415 for 2D symbols have become the global standards for grading printed barcodes.
-
Product
Voltage And Current Calibrator
-
Precision Mastech Enterprises Co.
A precision instrument designed to generate (source) and measure precise electrical signals.
-
Product
Calibration Kit
N911
-
*N911 Calibration Kit, * Frequency Range: up to 9 GHz, * Impedance: 50 Ohm, * Connector Type: N-type.
-
Product
Trace Level Portable Gas Calibrator
Model T750U
-
Teledyne Advanced Pollution Instrumentation
The Model T750U is a portable, microprocessor based calibrator for precision trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations. The T750U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field.
-
Product
Calibration Plates
-
MVTec provides precision-manufactured calibration plates to its customers. The plates are necessary to accurately calibrate a machine vision setup. MVTec’s calibration plates are available in different materials and in sizes ranging from 2cm×2cm up to 32cm×32cm. Contact your local distributor for assistance with choosing the right plate size and material for your application.
-
Product
Time to Amplitude Converters and Calibrator
-
A Time-to-Amplitude Converter (TAC) can achieve exceptional precision by using an analog technique to convert small time intervals to pulse amplitudes. When a timing application demands picosecond precision, a time-to-amplitude converter is a prime candidate. A time-to-amplitude converter is a productive solution for measurements less than 10 μs when time resolutions from 10 ps to 50 ns are required.
-
Product
Differential Calibration Substrates
-
The GGB Industries, Inc., line of DIFFERENTIAL CALIBRATION SUBSTRATES allows the user to calibrate any GGB Industries, Inc., microwave Picoprobe at the probe tip. The underlying principal of the calibration of a measurement system is to provide accurate known standards to which the measurement system can be connected.