CFL Testing Instruments
CFL testing instruments of Lisun Group includes: High Frequency Fluorescent Lamp Test, Adjustable Reference Ballast, Digital Torsion Meter, Multiplex temperature tester, Lamp cap gauge, etc.
-
Unlisted Product
High Frequency Power Supply
HFP-800
-
• Program control output voltage and easy operation • Set data easily with a memory chip, unnecessary to set for many times • Display on four windows, each window shows one parameter independently • Application for all kinds fluorescent lamps such as 50Hz/60Hz T8/T12 tube or 25KHz T5 Tube • It is according to double-ended fluorescent lamps adoptting the IEC 60081 (GB/T10682) and the single-ended fluorescent lamps adoptting the IEC 60901 (GB/T17262)
-
Unlisted Product
Adjustable Resistance Ballast
RB-3
-
RB-3 is designed according to the following standard requirements: IEC 60929 (GB/T15144), double-ended fluorescent lamp adoptting the IEC 60081 (GB/T10682) and the single-ended fluorescent lamp adoptting the IEC 60901 (GB/T17262) The RB-3 works with HFP-800 (High Frequency Power Supply ) and LPS-3 (Auxiliary Power Supply) to be an IEC Standard Test System which used to test the Frequency Fluorescent Lamp such as T5 Tube, please click here to learn the more details
-
Unlisted Product
Lamp Preheat Assistant Source
LPS-3
-
The LPS-3 works with HFP-800 (High Frequency Power Supply) and RB-3 (Adjustable Resistance Ballast) to be an IEC Standard Test System which used to test the Frequency Fluorescent Lamp such as T5 Tube, please click here to learn the more details
-
Unlisted Product
Adjustable Reference Ballast
-
According to Double end fluorescent lamp of IEC 60081 (GB/T10682) and the single-ended fluorescent lamp of IEC60901 (GB/T17262), ANSI C78.81 and ANSI C82.3, DYJ Reference Ballast is used to test for 4w~85w fluorescent lamp and electronic ballast test. Specification: • Inductance: 0~1240Ω (adjustable) • Inductance Power Factor COSφ: 0.075~0.120 • Resistance: 0~111Ω (adjustable) • Current Range 0.150~0.670A (Imax: 1A) • Order Code: DYJ-50HZ is for 50Hz lamp test and DYJ-60HZ is for all 60Hz lamp test
-
Product
Adjustable High Frequency Reference Ballast
HCS-109A
-
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
Product
Multiplex Temperature Tester
TMP-8/TMP-16
-
• 8 channels temperature signal (TMP-8) or 16 channels temperature signal (TMP-16) • T type or K type thermocouple • Temperature range: -40 ~ 300°C. Testing accuracy: 0.5% • Channel sequence is displayed by 2 LED and temperature is displayed by 4 LED • Freely set up the software with PC and record the change of temperature and select the channel.
-
Product
Multiway Life Tester
CH316
-
Measure 16 samples at the same time, evaluate and record the life of each sample. Very flexible: Samples can be added and changed at anytime. The life of each sample is readable at anytime. The switch ON/OFF time is adjustable (Test period is min 1s). Automatically remember the test result when the power is off, and resume the old measurement when power is on. Sound and light alarm when the products were failed.
-
Unlisted Product
Digital Torsion Meter
CH338
-
Digital Torsion Meter is mostly applied to measure the torque of all kinds of luminaries lamp cap. The CH338 is a newly developed intelligent product with microprocessor built-in. Specification: • Range: 0~10N•m; Accuracy ≤1% • Repeatability ≤0.5%FS; Over loading: 120%FS • It can measure the clockwise and anti-clockwise torque of lamp cap and it can preset upper limit alarm. The data won’t be lost after shutting down the instrument. • Instrument is convenient to be used because it has several mating clamps of various lamp caps such as E27/E26, B22d, E14/E12, G13/G5 and so on.
-
Product
GNG-* “Go” and “Not go”gauge
GNG-*
-
According to the requirement of IEC 60061, Lisun produced high accuracy and high quality “Go” and “Not go” gauge • GNG-E27 is for E27 lamp cap standard source measurement. It includes 7006-27B-1, 7006-28A-1, 7006-27C-1, 7006-50-1, 7006-51A-2, 7006-51-2 • GNG-E27H is for E27 lamp holder standard source measurement. It includes 7006-25A-2, 7006-26-4, 7006-21-5, 7006-22A-4, 7006-22B-1, 7006-22C-1, 7006-22D-1 • GNG-E14 is for E14 lamp cap standard source measurement: 7006-27F-1, 7006-54-2, 7006-27G-1, 7006-55-2 • GNG-E40 is for E40 lamp cap standard source measurement: 7006-27-7, 7006-28D-1, 7006-52-1, 7006-53-1 • GNG-B22D is for B22d lamp cap standard source measurement: 7006-12-8, 7006-15-7, 7006-20-4, 7006-12A-2, 7006-12B-2, 7006-15A-2, 7006-13-5, 7006-17B-1 • GNG-B22DH is for B22d lamp holder standard source measurement: 7006-12A-2, 7006-12B-2, 7006-15A-2, 7005-10-8
-
Product
Spectrophotometer & Integrating Sphere Test System
LPCE-1
-
This Test System is suitable for photometric and colorimetric measurement of luminaries such as Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps), CCFL and LED. The measured data meets the requirements of CIE and IES LM-79 for the measurement of photometry and colorimetry.