Validyne Engineering
A leading manufacturer of pressure transducers, pressure transmitters, signal conditioning in rack mount format and in portable units for field testing, and data acquisition systems with expandable chassis designs as well as PC based products for industrial and laboratory testing applications.
- (818) 886-8488
- (818) 886-6512
- sales@validyne.com
- 8626 Wilbur Avenue
Los Angeles, CA 91324
United States of America
-
Product
High Line Pressure Transducer with Digital Interface
P368
-
The Validyne model P368 is a digital differential pressure transmitter designed for high line pressures and industrial pressure measurement applications. Full scale ranges of 8 psid to 10,000 psid are available. The on-board microprocessor provides high accuracy and improved stability in changing thermal environments. Communication via RS485, USB or CanBus provides remote zero and span adjustment as well as digital pressure readings in engineering units.
-
Product
Vehicle Pressure Acquisition System
VPAS
-
The Vehicle Pressure Acquisition System (VPAS) is designed to record and display up to 8 or 16 low pressure measurement points for the investigation of vehicle pressures within the passenger cabin, in HVAC ducting or with respect to the exterior of the vehicle. Validyne DP103 pressure sensors can be ordered with full scale ranges as low as 0.1 in H20 and up to 55 in H20.
-
Product
Network Sensor Interface for USB Pressure Transducers
SI314
-
The Validyne model SI314 is a network interface that connects our model P61 USB pressure Transducer to your smart phone or network web browser. The SI314 supports Ethernet and Wi-Fi connections and will display current pressure readings and transducer status on any web browser or via smart phone. The SI314 also displays the transducer temperature, date of calibration, model and serial numbers and these can be viewed wirelessly or by Ethernet connection. The SI314 makes your P61 accessible from anywhere in the world. Data logging of pressure data is configured via a web browser or smart phone and readings may be stored once per minute to once per hour. A thumb drive or memory card collects the data in comma separated file format(csv) for download to your computer. The data may also be accessed via the network. A graph of the data is also generated on request. A Twitter function allows pressure data to be tweeted from the SI314 at user-defined intervals. The transducer zero and span calibration adjustments are password protected and operated via browser buttons. No potentiometer adjustments are required to calibrate the P61 transducer. Contact our Sales Department for a link to the Demo!
-
Product
Test and Measurement Pressure Transducer
P895
-
The P895 is designed for a wide variety of pressure measurements where high resistance to vibration and superior stability through temperature change is required. The zero and full-scale output calibrations are set by the potentiometer adjustments accessible from the top cover.
-
Product
Data Acquisition PCI Card
UPC2100
-
The UPC2100 PCI Sensor Interface card provides real-world data acquisition and control for your PC. Up to 16 sensor inputs in any mix or combination are accepted by the UPC2100. No external signal conditioning is required. The UPC2100 includes configuration and data acquisition software and is compatible with C#, .NET, C++, Visual Basic, LabView.
-
Product
Easy Sense Software
-
Easy Sense 2100 is available for use with the UPC2100. Easy Sense 225x is used with the Universal Data Acquisition System(UDAS) or the USB2251. The Software includes a GUI configuration utility that allows the user to set sensor type, gain range, channel, and all other input parameters. The configuration can be saved to non-volatile memory on the card so that the UP2100 or the UDAS can be used in embedded applications.
-
Product
Portable Carrier Demodulator with Digital Display
CD379
-
The CD379 is a portable, completely self contained digital transducer indicator. In addition to the front panel liquid crystal digital display, the unit also provides a 2 Vdc analog output suitable for recording, remote display or control purposes. The unit is for use with all variable reluctance transducers and features solid state electronics, 3 1/2 digit liquid crystal display and battery pack with six 1.5V penlight cells for truly portable operation. The unit can also be powered from an external DC power supply or AC battery eliminator (converter) module.
-
Product
Multi-Channel Carrier Demodulator
CD280
-
The CD280 Carrier Demodulator is a complete multi channel system in a small package which houses a plug-in power supply and 4 carrier demodulator circuit boards. The power supply provides regulated 5 Vac 5 kHz carrier power for Variable Reluctance and LVDT transducers , and the carrier demodulators demodulate and amplify the input signals to a 10 Vdc full-scale output. Zero and span adjustments are available for each channel. The system operates from 115 Vac, 50 to 400 Hz, line power.
-
Product
Variable Reluctance Pressure Sensor with All-Welded Construction
DP10
-
The DP10 Pressure Sensor, is designed for low and medium pressure measurements, to laboratory accuracy, of corrosive liquids and gases. In typical AC excited bridge circuits, this transducer delivers a full scale output of 30 mV per volt at 3kHz. The unit operates with carrier system including the Validyne CD15 since wave carrier demodulator and CD16 miniature DC input DC output carrier demodulator.
-
Product
Test and Measurement Grade Pressure Transducer for CAN Bus
P896
-
The P896 is a test and measurement grade pressure transducer for applications requiring high accuracy and outstanding performance through ambient temperature changes. The P896 is digitally compensated and corrected to provide high accuracy pressure measurement in a robust cylindrical form factor.
-
Product
High Line Pressure Variable Reluctance Pressure Sensor to 10,000 psid
DP360/DP363
-
The DP360 can be calibrated for a full scale as low as ±50 psid while withstanding high static line pressure. Low differential pressure may be measured at static pressures as high as 10,000 psig with a maximum 3% FS zero shift error.