Validyne Engineering
A leading manufacturer of pressure transducers, pressure transmitters, signal conditioning in rack mount format and in portable units for field testing, and data acquisition systems with expandable chassis designs as well as PC based products for industrial and laboratory testing applications.
- (818) 886-8488
- (818) 886-6512
- sales@validyne.com
- 8626 Wilbur Avenue
Los Angeles, CA 91324
United States of America
-
Product
Very Low Pressure Variable Reluctance Sensor
DP103
-
The Validyne DP103 is designed for exceedingly low differential pressure measurement applications where high accuracy is required under rough physical conditions. With full scale ranges down to -0.008 psid (-0.56cm H2O), this instrument is being used in the measurement of very low flow rates of gases where symmetrical pressure cavities are required for dynamic response. It is also used in very small leak detection and pressure null detection systems.
-
Product
Ultra Low Pressure Transmitter
P532
-
Validyne's P532 Pressure Transmitters are ideally suited for measuring extremely low liquid and gas pressures in industrial applications. Full-scale differential pressure ranges from 0.10 H2O to 2 H2O with line pressure rating of 100 psig, and ranges of 2 H2O to 3200 psid with line pressures up to 3200 psig are offered. Gauge pressure ranges start at 0.10 H2O and absolute pressure from 0.08 psia full-scale. This unique design, which utilizes a diaphragm-type variable reluctance pressure sensor, provides many outstanding advantages including:
-
Product
Multi-Channel Carrier Demodulator
CD280
-
The CD280 Carrier Demodulator is a complete multi channel system in a small package which houses a plug-in power supply and 4 carrier demodulator circuit boards. The power supply provides regulated 5 Vac 5 kHz carrier power for Variable Reluctance and LVDT transducers , and the carrier demodulators demodulate and amplify the input signals to a 10 Vdc full-scale output. Zero and span adjustments are available for each channel. The system operates from 115 Vac, 50 to 400 Hz, line power.
-
Product
Pressure Sensor Interface
USB2251
-
The USB2251 Pressure Sensor Interface provides real-world data acquisition for your PC via the USB port. 8 calibrated variable reluctance pressure sensor inputs are accepted by the USB2251. No external signal conditioning is required.The USB2251 includes a connector panel for sensor cables, calibration constants for each sensor , configuration and data acquisition software. The USB2251 produces a floating-point value for all readings, directly in engineering units.The USB2251 can record pressure readings up to 5000 samples per second. Combined with the fast response of the Validyne VR pressure sensors, the USB2251 is ideal for transient pressure studies. The USB2251 is compatible with the following Validyne variable reluctance pressure sensors: AP10, DP103, DP10, DP45, DP15 DP360, DP215, and DP363. Each sensor is calibrated with the USB2251 at the factory and is ready to make measurements.
-
Product
Test and Measurement Grade Pressure Transducer for CAN Bus
P896
-
The P896 is a test and measurement grade pressure transducer for applications requiring high accuracy and outstanding performance through ambient temperature changes. The P896 is digitally compensated and corrected to provide high accuracy pressure measurement in a robust cylindrical form factor.
-
Product
Variable Reluctance Absolute Pressure Sensor
AP10
-
The AP10, Absolute Pressure Sensor, is designed for low and medium pressure measurements, to laboratory accuracy, of corrosive liquids and gases. In typical AC excited bridge circuits, this transducer delivers a full-scale output of 40 mV per volt at 3kHz. The unit operates with carrier systems including the Validyne CD15 sine wave carrier demodulator and CD16 miniature DC input DC output carrier demodulator to produce a high level analog DC output suitable for recording and control.
-
Product
Pressure Transducers with CAN Bus Interface
P66
-
The Validyne model P66 is a digital differential pressure transmitter designed for industrial pressure measurement applications. The on-board microprocessor provides high accuracy and improved stability in changing thermal environments. Communication via CAN Bus provides remote zero and span adjustment as well as digital pressure readings in engineering units or pressure counts.
-
Product
Wet-Wet Differential Pressure Sensor
DP303
-
The DP303 features "take-apart" construction enabling the user to easily disassemble the unit for cleaning or to change full scale range by exchanging the sensing diaphragm. As noted from the Pressure Range/Diaphragm Selection Chart on the reverse side of this Data Sheet, a family of interchangeable diaphragms are available to cover virtually any full scale pressure range from 0.08 psid full scale to 5,000 psid full scale-all rated for operation at 5,000 psig line pressure!
-
Product
Test and Measurement Pressure Transducer
P895
-
The P895 is designed for a wide variety of pressure measurements where high resistance to vibration and superior stability through temperature change is required. The zero and full-scale output calibrations are set by the potentiometer adjustments accessible from the top cover.
-
Product
General Purpose Basic Carrier Demodulator
CD15
-
The CD15 Sine Wave Carrier Demodulator operates with variable reluctance transducers to provide a DC output signal for dynamics as well as steady state measurements. A 5kHz sine wave excitation is applied to the two inductance ratio arms of the transducer and the resulting output is demodulated and amplified using the latest integrated circuit techniques. The DC output is obtained from an active filter circuit and gives a uniform response from steady state to 1000 Hz. The low impedance sine wave excitation allows operation with the transducer located over 1,000 feet from the CD15.
-
Product
USB-COM Data Logger
-
The USB-COM Utility is a free data logging andconfiguration program for use with the Validyneseries of USB or Serial pressure transducers.USB-COM Utility also comes in a premiumversion that allows up to eight signals to begraphed simultaneously while being recorded toa .csv file. The graph X and Y axis may bescaled to any values set by the user. A separatehistorical graph provides a complete visualrecord of the signals from the start of logging.
-
Product
HVAC Pressure Transmitter
DP850/851
-
The DP850/851 transmitters are designed for low pressure measurement in HVAC applications. The DP850 is available in full scale pressure ranges as low as 0.25 inH2O and the DP851 can be ranged to 0.025 inH2O full scale. Both models are available in 4-20 mA or 0 to +5 Vdc signal output options.
-
Product
Speed Pick-up
SU63
-
The Validyne SU63 is an AC inductive speed pick-up used for RPM measurement on high-speed rotating equipment. The SU63 is a tightly-wound coil with a laminated core that can be conveniently mounted on rotating equipment so that the magnetic field of a magnetized nut or part passes through the coil windings. The moving magnetic field produces a voltage within the coil proportional to its rate of change and the strength of the permanent magnetized part. The frequency of this inductive voltage spike is fed into an oscilloscope or counter to determine RPM.
-
Product
Low Pressure Variable Reluctance Sensor
DP45
-
The Validyne DP45 Very Low Differential Pressure Transducer is designed for extremely low pressure measurement in the order of 1 inch water column. This instrument is used extensively in connection with flow measurements where dynamic response at low flow rates is required. Dynamic line pressure effects are minimized due to the combination of low internal volume, symmetrical construction, and small volumetric displacement inherent in the DP45 design.
-
Product
High Line Pressure Transducer with Digital Interface
P368
-
The Validyne model P368 is a digital differential pressure transmitter designed for high line pressures and industrial pressure measurement applications. Full scale ranges of 8 psid to 10,000 psid are available. The on-board microprocessor provides high accuracy and improved stability in changing thermal environments. Communication via RS485, USB or CanBus provides remote zero and span adjustment as well as digital pressure readings in engineering units.