Validyne Engineering
A leading manufacturer of pressure transducers, pressure transmitters, signal conditioning in rack mount format and in portable units for field testing, and data acquisition systems with expandable chassis designs as well as PC based products for industrial and laboratory testing applications.
- (818) 886-8488
- (818) 886-6512
- sales@validyne.com
- 8626 Wilbur Avenue
Los Angeles, CA 91324
United States of America
-
Product
Variable Reluctance Pressure Sensor with All-Welded Construction
DP10
-
The DP10 Pressure Sensor, is designed for low and medium pressure measurements, to laboratory accuracy, of corrosive liquids and gases. In typical AC excited bridge circuits, this transducer delivers a full scale output of 30 mV per volt at 3kHz. The unit operates with carrier system including the Validyne CD15 since wave carrier demodulator and CD16 miniature DC input DC output carrier demodulator.
-
Product
Speed Pick-up
SU63
-
The Validyne SU63 is an AC inductive speed pick-up used for RPM measurement on high-speed rotating equipment. The SU63 is a tightly-wound coil with a laminated core that can be conveniently mounted on rotating equipment so that the magnetic field of a magnetized nut or part passes through the coil windings. The moving magnetic field produces a voltage within the coil proportional to its rate of change and the strength of the permanent magnetized part. The frequency of this inductive voltage spike is fed into an oscilloscope or counter to determine RPM.
-
Product
Multi-Channel Carrier Demodulator
CD280
-
The CD280 Carrier Demodulator is a complete multi channel system in a small package which houses a plug-in power supply and 4 carrier demodulator circuit boards. The power supply provides regulated 5 Vac 5 kHz carrier power for Variable Reluctance and LVDT transducers , and the carrier demodulators demodulate and amplify the input signals to a 10 Vdc full-scale output. Zero and span adjustments are available for each channel. The system operates from 115 Vac, 50 to 400 Hz, line power.
-
Product
Portable Carrier Demodulator with Digital Display
CD379
-
The CD379 is a portable, completely self contained digital transducer indicator. In addition to the front panel liquid crystal digital display, the unit also provides a 2 Vdc analog output suitable for recording, remote display or control purposes. The unit is for use with all variable reluctance transducers and features solid state electronics, 3 1/2 digit liquid crystal display and battery pack with six 1.5V penlight cells for truly portable operation. The unit can also be powered from an external DC power supply or AC battery eliminator (converter) module.
-
Product
Vehicle Pressure Acquisition System
VPAS
-
The Vehicle Pressure Acquisition System (VPAS) is designed to record and display up to 8 or 16 low pressure measurement points for the investigation of vehicle pressures within the passenger cabin, in HVAC ducting or with respect to the exterior of the vehicle. Validyne DP103 pressure sensors can be ordered with full scale ranges as low as 0.1 in H20 and up to 55 in H20.
-
Product
Draft Range Trasmitter
DR800
-
The Validyne Model DR800 Draft Range Transmitter is designed exclusively for very low pressure measurement needs. It has a "true" full-scale range as low as 0.25" H2O, making it ideal for air flow control applications. It can be turned down to 0.1" H2O; higher full-scale ranges to 100" H2O are available. The DR800 offers 0.5% accuracy and an operating temperature range of -20F to +185F. The total combined temperature effects are less than 3%/100F.
-
Product
High Line Pressure Transducer
P365
-
The P365D transducer is designed to make low differential pressure measurements at high static line pressures. Operating from unregulated 9 to 55Vdc, the P365D is available with 4-20mA, 5Vdc or isolated 5Vdc output over full scale pressure ranges from 8 to 10,000 psid. The output shift due to static pressure will not exceed 3% of full scale, up to a line pressure of 10,000 psig.
-
Product
Single-Channel DC Powered Carrier Demodulator
CD16
-
The CD16 Miniature Carrier Demodulator is designed to deliver a 0 to 5 Vdc output from a variable reluctance transducer and operate from unregulated 9 to 55 Vdc power. A square wave excitation of 5 kHz is furnished to the transducer and the solid state integrated circuit amplifier and demodulator converts the transducer signal to an analog dc output. Zero and Span adjustments are made through access holes in the case.
-
Product
Portable Digital Manometer
PS309
-
Featured are an integral variable reluctance transducer, solid state electronics module, 3 digit liquid crystal display (LCD)* and battery pack with six 1.5V penlight cells for truly portable operation. The units can also be powered from an external DC power supply or AC battery eliminator (converter) module. The transducer features all corrosion resistant materials in contact with the pressure media (both ports in differential units), very low internal cavity volumes and ultra-low volumetric displacement with full-scale pressure excursion. Transducer calibration is unaffected by dielectric properties of the sensed fluid. Gauge and differential transducers may be disassembled and range changed by simple diaphragm replacement.
-
Product
General Purpose Pressure Transducer and Transmitter
P55
-
The robust P55 pressure transducer provides cost-effective reliability for severe test environments. With extreme resistance to shock and vibration, the P55 pressure transducer delivers the same high-level performance expected from more delicate differential pressure transducers and pressure transmitters. With variable reluctance sensing technology, the P55 pressure transducer delivers fast dynamic response, high resistance to vibration and superior signal stability through ambient temperature change for a wide variety of low-pressure to high-pressure measurements. The P55 pressure transducer will accept both liquids and gases directly at the sensing diaphragm and there are no internal isolation fluids to slow the sensor response or cause excessive temperature drift errors.
-
Product
Wet-Wet Differential Pressure Sensor
DP303
-
The DP303 features "take-apart" construction enabling the user to easily disassemble the unit for cleaning or to change full scale range by exchanging the sensing diaphragm. As noted from the Pressure Range/Diaphragm Selection Chart on the reverse side of this Data Sheet, a family of interchangeable diaphragms are available to cover virtually any full scale pressure range from 0.08 psid full scale to 5,000 psid full scale-all rated for operation at 5,000 psig line pressure!
-
Product
USB-COM Data Logger
-
The USB-COM Utility is a free data logging andconfiguration program for use with the Validyneseries of USB or Serial pressure transducers.USB-COM Utility also comes in a premiumversion that allows up to eight signals to begraphed simultaneously while being recorded toa .csv file. The graph X and Y axis may bescaled to any values set by the user. A separatehistorical graph provides a complete visualrecord of the signals from the start of logging.
-
Product
Low Range Low Cost OEM Differential Pressure Transducer
P17
-
The P17 OEM Low Range Low Cost pressure transducer features high sensitivity to very low pressures with full scales available down to 0.1 In H2O. Output signal is 5 Vdc and power can be +5 to +28 Vdc. Zero and Span adjustments are included. The P17 has a robust steel sensor construction.
-
Product
Variable Reluctance Absolute Pressure Sensor
AP10
-
The AP10, Absolute Pressure Sensor, is designed for low and medium pressure measurements, to laboratory accuracy, of corrosive liquids and gases. In typical AC excited bridge circuits, this transducer delivers a full-scale output of 40 mV per volt at 3kHz. The unit operates with carrier systems including the Validyne CD15 sine wave carrier demodulator and CD16 miniature DC input DC output carrier demodulator to produce a high level analog DC output suitable for recording and control.
-
Product
Test and Measurement Grade Pressure Transducer for CAN Bus
P896
-
The P896 is a test and measurement grade pressure transducer for applications requiring high accuracy and outstanding performance through ambient temperature changes. The P896 is digitally compensated and corrected to provide high accuracy pressure measurement in a robust cylindrical form factor.