Eltel Industries
Market leaders in India for the manufacture and development of test instruments for electrical power industries and utilities.
- 91 80 22255467
- 91 80 22252733
- marketing@eltelindustries.com
- 311 Embassy Centre
Crescent Road
Bangalore, 560 001
India
-
Product
Digital Micro Ohmmeter
-
*For fast and accurate measurements of low resistance on Switch Contacts, SF-6 Switch Gear, Bushbars, Splices, Joints, Fuses, Breaker Contacts, and Rail Bonds.*100A DC continuous current in 4 ranges of 10A, 20A, 50A and 100A*4 1/2 digit display for higher resolution*Wide resistance range of 20µΩ to 200mΩ in 5 ranges*Suitable for operation in energized switchyard conditions*SMPS based- lightweight and portable
-
Product
Relaying Current Transformer Analyser
-
*Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.
-
Product
Low Resistance Ohm Meters
DMO-100D
-
For fast and accurate measurements of low resistanceon Switch Contacts, SF-6 Switch Gear, Bushbars, Splices, Joints, Fuses, Breaker Contacts, and Rail Bonds. • 100A DC continuous current in 4 ranges of 10A, 20A, 50A and 100A
-
Product
Accessories for Ratio meter
-
The CVT Range Extender is an accessory for the ELTEL TRM-100,TRM-150,TRM-200 and ATRM-200 Transformer Ratio Meters and designed to test high ratios of CVTs used on High Voltage Systems. Provides a 1:40 range extension.
-
Product
ANSI Metering Current Transformer Burden
-
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
Product
Automatic Three Phase Transformer Ratio Meter
-
*For automatic measurement of ratio & phase angle deviation. *Digital presentation of ratio & phase angle deviation. *Ratio range of 0.2 to 199.99 to 1 in three ranges. *Automatic polarity indication. *High accuracy and resolution Accessories: Range Extender 1:10
-
Product
10 KV Oil Cell
-
• Operating range 2 to 12kV for a stress of 200 to 1100V/mm • Cell capacitance -65pF nominal • The cell is suitable for use with Eltel models CST- 12KSA, ACTS-5k & ACTS- 12k test sets • Measurement at 10kV at ambient temperature only
-
Product
Manual Dielectric Constant, Tan Delta & Resistivity Test Set
-
*AC and DC test Voltages switched internally.*Direct digital display of test voltages.*Auto ranging and direct read out of volume resistivity.*Cell constant adjustment and Tan Delta zero correction.*Built-in protection for test sample flash over.
-
Product
Standard CT
2000A
-
• High accuracy of 2000/5A (0.05%) • multiple ratios • Various Current ratings
-
Product
High Voltage Capacitance & Tan Delta Test Set
-
*Aesthetically designed Single Unit consisting of Measuring Bridge, Power Supply with in-built Standard Capacitor. Ideal for field /portable applications.*Highly compact & Portable – Approx 66Kgs only.*Advanced Protection Circuitry –specially suitable for 400kV s/s applications.*Successfully passed all required EMI/EMC Tests at SAMEER Chennai IEC 61000-4-2;IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-11;*Improved Plug-in type of “Power In” and “Gnd” connectors.*Preo 2 Stage RF Power line Filters incorporated for 230V Power Input and Bridge Power Input for improved EMI Power line Protection*Improved 2 sets of LV measuring cables.*Improved HV cable outer covering hosepipe for rugged field use.
-
Product
IEC Current Transformer Burden
-
• Burdens of 1A and 5A for IEC & ANSI specifications are available • 40VA, 20VA, 10VA, 7.5VA, 6.25VA, 5 VA and different combinations of these at 0.8 PF 3.75, 2.5, 1.25 & 1VA at 1.0 PF
-
Product
Single Phase Transformer Ratio Meter
-
*Ideal for VT testing*Bushing Current Transformers (BCTs)*Higher resolution*Excitation current meter
-
Product
Resistivity Meter
-
Resistivity meterRSM-500 is used for measuring the volume resistivity of transformer oil and other electrical insulating liquids. • Auto ranged from 109 to 1015 ohm cm • Test voltages: internally generated +500V DC
-
Product
Automatic Dielectric Constant, Tan Delta & Resistivity Test Set
-
*Fully automatic or manual measurement In-built AC/DC voltage sources.*RS232 computer interface & USB printer interface provided.*Menu-driven software operation.*Data storage facility.