Product
Automatic Three Phase Transformer Ratio Meter
ATRM PLUS
-
*Fully Automatic measurement.*Wide selection of Excitation Voltages of 10V, 40V, 100V, 230V & 250V from front panel.*4V Excitation voltage provided for CT measurements*Ratio range of up to 5000; direct display of measured ratio.*No conversions required.*Automatic Jumper selecting as per the vector*Diagram of Transformer.*Automatic testing of all 3 phases in 3 phase transformers*Without manual intervention.*Displays % deviation from a nominal ratio.*External storage facility using pen drive.*Internal storage up to 10000 readings.*Touch screen 7” Color TFT display with backlighting with*Resolution of 800 X 480.*Tap changer facility.*Computer interface using RS-232 or USB.*Windows Interface software provided for data transfer.*USB printer interface.*Four terminal measurements to reduce errors due to*Winding and lead resistance.*Auto print and storage facility.Fast measurements.
-
Product
Automatic Dielectric Constant, Tan Delta & Resistivity Test Set
-
*Fully automatic or manual measurement In-built AC/DC voltage sources.*RS232 computer interface & USB printer interface provided.*Menu-driven software operation.*Data storage facility.
-
Product
Automatic Instrument Transformer Test Set
-
*ARM 9 processor controlled measurements*Measures total burden connected to test sample*Internal data storage facility upto 1 lakh readings*Digital display of test results on 800 x 480 TFT color display.*Latest IEC 61869 / ANSI C57.13-2008 / IS-2705 standards incorporated*VGA Port to interface with bigger display / monitor*Both Voltage & Current Transformer testing with one test set*5 and 1 Amp CT testing using either 5 or 1 Amp standard CT*Identifies ANSI, IEC, IS-P, IS-PR, BS, BS-S, IEC-S, IS, IS-S, AS, AS-M, AS-ME standards for CT & VT*USB memory storage*Available in three versions: AITTS Plus , ACTTS Plus & AVTTS Plus
-
Product
IEC Current Transformer Burden
-
• Burdens of 1A and 5A for IEC & ANSI specifications are available • 40VA, 20VA, 10VA, 7.5VA, 6.25VA, 5 VA and different combinations of these at 0.8 PF 3.75, 2.5, 1.25 & 1VA at 1.0 PF
-
Product
Resistivity Meter
-
Resistivity meterRSM-500 is used for measuring the volume resistivity of transformer oil and other electrical insulating liquids. • Auto ranged from 109 to 1015 ohm cm • Test voltages: internally generated +500V DC
-
Product
Standard Capacitor
-
• 3 terminal design • SF-6 Gas filled • 15kV, 33kV & 50kV models available
-
Product
Relaying Current Transformer Analyser
-
*Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.
-
Product
Transformer Winding Resistance Meter
10A
-
*10A DC continuous current in 4 ranges of 0.01A, 0.1A, 1A and 10A.*4 ½ digit display for higher resolution.*Dual channel measurement.*Suitable for operation in energized switchyard conditions.*Specialized protection circuits for suppression of inductive voltage kickback.*SMPS based - lightweight and portable.
-
Product
ANSI Relaying Current Transformer Burden
-
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
Product
Standard CT
3200A
-
• High accuracy of 3200/5A (0.005%) • multiple ratios • Various Current ratings
-
Product
Electronic Potential Divider
-
• Provides many ratios over a wide range • Small ratio and phase errors • Models operating at different voltages are available
-
Product
Low Resistance Ohm Meters
DMO-100D
-
For fast and accurate measurements of low resistanceon Switch Contacts, SF-6 Switch Gear, Bushbars, Splices, Joints, Fuses, Breaker Contacts, and Rail Bonds. • 100A DC continuous current in 4 ranges of 10A, 20A, 50A and 100A
-
Product
ANSI Potential Transformer Burdens
-
The ANSI Potential Transformer Burden Model PB-96-ANSI is designed for loading the Voltage transformers during accuracy tests as per ANSI standard C57.13. The PB-96-ANSI is a dual input ANSI burden providing the inputs of both 120V & 69.3V. It can be used along with the ELTEL Automatic Instrument transformer Test Set. AITTS-98 to test VTs as per ANSI standards.