HORIBA, Ltd.
The HORIBA Group of worldwide companies provides an extensive array of instruments and systems for applications ranging from automotive R&D, process and environmental monitoring, in-vitro medical diagnostics, semiconductor manufacturing and metrology, to a broad range of scientific R&D and QC measurements.
- +81 75 313 8123
- +81 75 321 0752
- info@horiba.co.jp
- 2, Miyanohigashi,
Kisshoin
Minami-Ku, Kyoto 601-8510
Japan
-
Product
Benchtop Conductivity Meter
LAQUA EC1500
-
Ideal for routine applications and student training.Good value for money: no fancy bells and whistles which sounds good but are rarely used.
-
Product
Thermo-Electrically Cooled Dual Mode Analog/Photon Counting Photmultiplier Tube (PMT)
CoolOne
-
For spectroscopy and microscopy experiments in the UV/Vis/NIR region of the spectrum, a photomultiplier tube (PMT) is the ideal detector for quantitative low light level measurements. A PMT is extremely sensitive, with very wide dynamic range so it can also measure high levels of light. PMT’s are also very fast so rapid changes in optical signals can be reliably monitored. As a practical matter, PMT’s are durable, long-lived, and economical.
-
Product
UV Man Spectrometer
-
UV Raman (with laser wavelengths below 400nm) can be used to probe specific sample properties, and benefit from experiment properties different from typical visible Raman measurements – for example, greatly increased Raman scattering efficiency, modified laser penetration within the sample, and resonance coupling to different chemical moeities. However, UV analyses come with a number of technical challenges, that require considered instrument design to allow UV Raman to be a truly useful tool for the researcher.
-
Product
Industrial QC/QA Analyzer - "Column Free" Molecular Fingerprinting Technology
Aqualog - A-TEEM
-
A-TEEM™ Molecular Fingerprinting is a new optical technique that is ideal for comprehensive component analysis in a variety QC/QA applications, from water to wine to pharmaceuticals and more. It is a simple, fast, “column free” spectroscopic technique that simultaneously measures the absorbance, transmission and fluorescence of samples in solution, and offers unique benefits over traditional analytical techniques, such as chromatography, mass spec, IR, etc.. Fundamentally, this technique is best applied to samples in solution that have fluorescing components, like an aromatic molecule, although it also detects non-fluorescing species via absorbance. The fluorescence EEM fingerprint technique has also been applied to solids and skin. Fluorescence is a highly sensitive technique compared to other spectroscopic techniques such as absorbance, FTIR and Raman, and the three-dimensional nature of the data provides for a better foundation for complex component analysis.
-
Product
Broadband Xe Light Source
PowerArc
-
75W Xe Ozone free light source for UV-Visible-NIR applicationsThe PowerArc™ is a complete, integrated light source that includes power supply, starter, high efficiency collection optics and lamp housing in one compact package.
-
Product
Deep Cooled UV-VIS/NIR Scientific Cameras
-
TE and cryogenically cooled CCD and EMCCD scientific cameras for ultra sensitivity from 200 nm to 1100 nmHORIBA Scientific offers a complete line of spectroscopic multi-channel detectors for scientific research. For spectral detection from UV to near-IR, two dimensional CCDs and indium gallium arsenide linear arrays offer a faster acquisition option over single point detectors with relatively high sensitivity. Coupled with HORIBA’s range of aberration corrected, flat field imaging spectrographs, custom spectroscopy packages can be assembled for a variety of applications.
-
Product
High Resolution Monochromators
FHR Series
-
With the fastest direct drive in this class, the FHR 1000 spectrometer offers a unique combination of speed, precision and high resolution, completely revolutionizing the large spectrometer market. Designed for researchers who require high accuracy with immediate results, the versatility of the FHR allows for utilization over a wide spectral range, extending from the UV to the IR. The instrument’s cast body design eliminates temperature induced stress and expansion, preventing any significant wavelength shifts or signal loss and allowing for optimal performance. This monochromator benefits from the highest quality of gratings, also designed and manufactured by HORIBA.
-
Product
X-ray Analytical Microscope Super Large Chamber Model
XGT-9000SL
-
Large chamber capacity (W x D x H) : 1030 mm x 950 mm x 500 mm. X-ray shield complying with JAIMAS0101-2001/ IEC1010-1 to protect you from X-ray exposure. Mapping area size up to 350 x 350 mm2 <15 µm spot size with ultra-high intensity without compromising sensitivity and spatial resolution. Dual types of detectors for transmission and fluorescent X-rays. Detectable element range down to C with a light element detector and He purge module.
-
Product
Carbon Sensor Conductivity Meter (Low concentration type)
HE-480C-GC
-
The length of the sensor has been reduced by 50% as compared to existing systems to reduce space requirements. At the same time, the measurement range has been increased tenfold, enabling the system to measure even samples with comparatively high concentrations. Two different types of chemicalresistant glassy carbon sensors can be used, making the system ideal for chemical dilution/recovery management and pure water recycling as well.
-
Product
Random Access Monochromator
DeltaRAM X
-
The patented DeltaRAM™ X microscope Illuminator is the ideal fluorescence illuminator for quantitative intracellular ion research. It utilizes a galvanometer-based Random Access Monochromator (RAM) that can switch between any wavelength in 2 milliseconds. The DeltaRAM™ X is a complete, self-contained, illuminator that includes a power supply, high intensity xenon light source, DeltaRAM™ X monochromator, TTL shutter and flexible liquid light guide. The wavelength position is a simple analog voltage control. All you need to add is a microscope adapter for your fluorescence microscope and a USB or PCI DAC interface depending on the software you will be using to drive the illuminator.
-
Product
In-line Sensor & Auto Range Switching Concentration Monitor
HF-960EM
-
Measures a wide range of HF concentration from low concentration to undiluted liquid. The HF-960EM achieves high precision measurement by the auto-correction range switching function. Also has the capibility of cleanliness with all PFA sensors. Measurement range: 0 - 50%.
-
Product
ICP-OES Spectrometers
-
ICP-OES spectrometers measure the concentration of elements from ppb to % using de-excitation of atoms and ions in a plasma. The robustness of our Ultima ICP spectrometers makes them ideal for applications common to mining, chemicals manufacture, salt production, wear metals in oil analysis, petrochemical, metallurgical production and precious metal refining.
-
Product
Field-installation Type Color Meter (Four-wire Transmission)
HU-200CL
-
HU-200CL connects flow through color detector Cl-20 and measures color and turbidity in the sample water. Suitable for monitoring purified water.
-
Product
Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For High-concentration)
HE-200H
-
HE-200H connects conductivity sensor (FES-125F,126F) and measures conductivity and temperature in the sample water. It can be used not only for measurement of electrical conductivity in aqueous solution, but also for concentration adjustment and rinse monitoring of CIP, etc., as well as for concentration monitor of process.
-
Product
Flat Carbon Sensor Conductivity meter
HE-960LF / FS-09F-1/2
-
It is effective to keep the dilution of Slurry constant. Maintaining an appropriate conductivity value contributes to process stability in the wafer polishing process. Even highly viscous sample liquids such as CMP Slurry can be measured without problems because they use a sensor structure that reduces the risk of the sample liquid sticking to the electrodes. In addition, the sensor is made of a wetted material with excellent chemical resistance, which meets the cleanliness requirements of semiconductor processes. In addition to the above, it can also be used for introduction at the semiconductor process development stage and conductivity control of special chemicals.